600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
Wire Size 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 0.83 in. / 21.082 mm
Conductor Count 4
Voltage Rating 600
Ampacity Rating 120

Product Details

Product Details

"The industry-standard for secondary three-phase residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance."

Why Electricians Choose Tulsa 4-4-4-4 Quadruplex Aluminum URD

The Tulsa 4-4-4-4 URD cable is the versatile solution for secondary underground three-phase power distribution. Specifically designed for applications requiring three phase conductors and a neutral, it provides a stable, high-performance solution for light commercial services, multi-family residential projects, and agricultural power. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.

  • 600V Reliability: Rated for continuous operation in wet or dry locations at temperatures up to 90°C, providing dependable power for 3-phase equipment.

  • Sunlight-Resistant XLP: Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points.

  • Easy-Identify Neutral: For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes.

  • Direct Burial Ready: Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit/duct systems.

Technical Specifications: Tulsa 4-4-4-4 URD

ENGINEERING OVERVIEW: 4-4-4-4 Quadruplex URD

  • Application: Designed for use in secondary distribution circuitswhere installed in duct or direct burial applications.

  • Voltage Rating: 600 Volts.

  • UL Listing: UL 854 (Service-Entrance Cable).

  • Conductor Material: Concentric stranded 1350-H19 series aluminum.

  • Phase Insulation: Black sunlight-resistant XLP (Cross-Linked Polyethylene).

  • Neutral Insulation: Black XLP with 3 extruded yellow stripes for easy identification.

  • Temperature Rating: 90°C (Wet or Dry).

  • Cable Outer Diameter: 0.83 inches (21.082 mm)

  • Ampacity (Direct Burial): 120 Amps.

  • Ampacity (In Duct): 85 Amps.

  • Compliance Standards: UL 854; Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692.

Common 4-4-4-4 Tulsa Quadruplex Applications

  • Three-Phase Service Entrance: The standard feeder for small commercial buildings or multi-family units requiring a 120/208V or 277/480V three-phase secondary service.

  • Small Industrial & Workshop Power: Ideal for powering three-phase motors, air compressors, and specialized machinery in detached workshops or agricultural facilities.

  • Commercial Site Lighting: A rugged and cost-effective solution for underground power distribution to parking lot light poles and exterior security lighting circuits.

  • Agricultural Infrastructure: Frequently used for powering irrigation control systems and small-scale barn equipment where three-phase power is available.

  • Direct Burial or Conduit: Extremely versatile and easy to handle; can be installed directly in a trench for residential projects or pulled through conduit for commercial site developments.

 

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

 

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.83 in. / 21.082 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 120
Direct Burial Rating Yes
Submersible No
Flexibility Rating Medium
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.269 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum Quadruplex Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Dyke 2 Gauge, 4 Conductor Quadruplex URD, Aluminum Direct Burial Cable.

4-4-4-4 Quadruplex Aluminum Direct Burial Cable, Tulsa URD

Parent SKU :  TUL-4URD

SKU :  TUL-4URD-100

600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
In Stock
Ships in 1-2 days

Parent SKU :  TUL-4URD

SKU :  TUL-4URD-100

$187/ea.
$461/ea.
$917/ea.
$1,824/ea.
$1.87/ft.
Please select an option
Min: 100 ft., Max: 20,000 ft.
Spool (100 ft.)
$187.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

"The industry-standard for secondary three-phase residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance."

Why Electricians Choose Tulsa 4-4-4-4 Quadruplex Aluminum URD

The Tulsa 4-4-4-4 URD cable is the versatile solution for secondary underground three-phase power distribution. Specifically designed for applications requiring three phase conductors and a neutral, it provides a stable, high-performance solution for light commercial services, multi-family residential projects, and agricultural power. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.

  • 600V Reliability: Rated for continuous operation in wet or dry locations at temperatures up to 90°C, providing dependable power for 3-phase equipment.

  • Sunlight-Resistant XLP: Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points.

  • Easy-Identify Neutral: For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes.

  • Direct Burial Ready: Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit/duct systems.

Technical Specifications: Tulsa 4-4-4-4 URD

ENGINEERING OVERVIEW: 4-4-4-4 Quadruplex URD

  • Application: Designed for use in secondary distribution circuitswhere installed in duct or direct burial applications.

  • Voltage Rating: 600 Volts.

  • UL Listing: UL 854 (Service-Entrance Cable).

  • Conductor Material: Concentric stranded 1350-H19 series aluminum.

  • Phase Insulation: Black sunlight-resistant XLP (Cross-Linked Polyethylene).

  • Neutral Insulation: Black XLP with 3 extruded yellow stripes for easy identification.

  • Temperature Rating: 90°C (Wet or Dry).

  • Cable Outer Diameter: 0.83 inches (21.082 mm)

  • Ampacity (Direct Burial): 120 Amps.

  • Ampacity (In Duct): 85 Amps.

  • Compliance Standards: UL 854; Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692.

Common 4-4-4-4 Tulsa Quadruplex Applications

  • Three-Phase Service Entrance: The standard feeder for small commercial buildings or multi-family units requiring a 120/208V or 277/480V three-phase secondary service.

  • Small Industrial & Workshop Power: Ideal for powering three-phase motors, air compressors, and specialized machinery in detached workshops or agricultural facilities.

  • Commercial Site Lighting: A rugged and cost-effective solution for underground power distribution to parking lot light poles and exterior security lighting circuits.

  • Agricultural Infrastructure: Frequently used for powering irrigation control systems and small-scale barn equipment where three-phase power is available.

  • Direct Burial or Conduit: Extremely versatile and easy to handle; can be installed directly in a trench for residential projects or pulled through conduit for commercial site developments.

 

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

 

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.83 in. / 21.082 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 120
Direct Burial Rating Yes
Submersible No
Flexibility Rating Medium
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.269 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum Quadruplex Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Dyke 2 Gauge, 4 Conductor Quadruplex URD, Aluminum Direct Burial Cable.

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.83 in. / 21.082 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 120
Direct Burial Rating Yes
Submersible No
Flexibility Rating Medium
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation:

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.269 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

The difference is the number of "hot" legs. Triplex (3 wires) is for single-phase systems common in standard residential homes. Tulsa Quadruplex (4 wires) features three phase conductors and one neutral, making it the requirement for three-phase systems used in commercial and industrial settings.

Yes. Tulsa 4-4-4-4 is engineered for direct burial. The rugged XLP insulation protects the aluminum conductors from soil acidity, moisture, and abrasion, though conduit is often used where the cable exits the ground for added physical protection.

No. Tulsa URD is not flame-retardant and does not carry an indoor NEC listing. It is designed for outdoor underground use only. Per code, it must transition to an indoor-rated cable (like SER or MC) shortly after entering a structure.

  • Direct Burial: Approximately 120 Amps
  • In Duct/Conduit: Approximately 85 Amps


Note: Always consult your local electrical inspector and NEC Table 310.15 to ensure the ampacity meets your specific service calculation.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us