4/0 4C Aluminum MC Cable with Bare Ground

Parent SKU :  MCA4/0-4

SKU :  MCA4/0-4-250

4 CONDUCTOR + GROUND • INTERLOCKING ARMOR • 600V • CUT TO LENGTH
Wire Size 4/0
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 1.82 in.
Conductor Count 4
Voltage Rating 600V
Ampacity Rating 205
Weight per Foot 1.35 lb

Get Product Details

Get Product Details

"A dependable industrial and commercial choice for high-amperage 3-phase feeder systems, branch circuits, and secondary sub-panel installations requiring a neutral conductor. Engineered with a lightweight, interlocking aluminum armor jacket, this pre-protected 4-conductor plus ground assembly eliminates the extensive material and labor expenses of traditional conduit piping. It allows electrical crews to route heavy service lines directly through walls, ceilings, and open cable trays in a fraction of the time."

Key Features & Benefits: 4/0-4 Aluminum MC Cable w/ Ground

4/0 AWG 4-Conductor Aluminum Metal Clad (MC) Cable delivers a completely code-compliant, pre-armored wiring solution designed to minimize field labor hours and maximize jobsite efficiency. Featuring four compact-stranded AA-8000 series aluminum phase conductors insulated with cross-linked polyethylene (XLPE/XHHW-2) and a dedicated bare grounding wire, the assembly is protected by an overall interlocking aluminum armor jacket.

  • Labor-Saving Armor: The integrated aluminum interlocked armor serves as its own flexible metallic protective raceway, removing the tedious labor of bending and installing separate EMT or rigid conduit systems.

  • AA-8000 Conductor Material: Manufactured with compact-stranded 8000-series aluminum alloy to ensure high electrical conductivity, dramatically reduced weight strain during long structural pulls, and excellent flexibility.

  • XHHW-2 Insulation: Individual phase conductors are insulated with cross-linked polyethylene (XLPE), providing elite resistance to heat, moisture, and electrical stress in challenging industrial environments.

  • Maximum Versatility: Code-approved for an exceptionally broad range of heavy-duty installations including 3-phase commercial distribution panels, large equipment feeders, vertical risers, and environmental air-handling spaces (plenums).

  • Cut to Length or Bulk Spools: Order custom cut-to-length footage to eliminate jobsite waste, or select full factory spools and reels for major commercial installation pulls.

Technical Specifications: 4/0-4/0-4/0-4/0 Aluminum Metal Clad (MC) w/ Ground

  • Conductor Configuration: 4 Insulated Conductors + 1 Bare Ground Wire

  • Conductor Size: 4/0 AWG

  • Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (per ASTM B800 & B801)

  • Conductor Colors (240V): Black, White, Red, Blue 

  • Ground Wire Size: 2 AWG (Bare Stranded Aluminum)

  • Insulation: High-Heat & Moisture Resistant Cross-Linked Polyethylene (XLPE / Type XHHW-2). A binder tape is wrapped over the insulated conductors' assembly.

  • Armor: Overall Aluminum Interlocked Armor

  • Voltage Rating: 600 Volts

  • Temperature Rating: -40°C to 90°C

  • Amp Rating (@ 75°C - NEC): 180 Amps

  • Amp Rating (@ 90°C - NEC): 205 Amps

  • Insulation Thickness: 0.055 inches

  • Diameter Over Armor: 1.82 inches

  • Net Weight: 1,350 lbs per 1,000 ft

  • Minimum Bending Radius: 12.46 inches (Calculated as 7x Diameter Over Armor)

  • Compliance Standards: UL 44, UL 1569 for Type MC Cable (CT Use Rated), NEMA WC-70/ICEA S-95-658, IEEE 1202 70,000 BTU/HR Vertical Tray Flame Test, ASTM B800 & B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces (plenums).

Common 4/0 4-Conductor Alum MC Cable Applications

  • 175A–200A Sub-Panel Feeds: Primary 3-phase, 4-wire feeder lines running from main distribution switchboards to 175A or 200A sub-panels in office complexes, retail centers, and multi-tenant commercial spaces.

  • Heavy HVAC & Mechanical Systems: Direct power feeds for large rooftop HVAC units (RTUs), commercial chillers, air compressors, and refrigeration equipment requiring a dedicated neutral.

  • Open Plenum & Drop-Ceiling Routing: Fully certified under NEC 300.22 for routing directly through environmental air-handling plenum spaces, dropped ceiling voids, and raised floors without conduit.

  • Commercial EV Charging & Transformers: Reliable power distribution for high-output commercial EV charging hubs, battery backup systems, and 480V-to-208V step-down transformer connections.

  • Multi-Story Vertical Shafts: Approved for vertical riser shafts in multi-family residential and high-rise commercial structures when secured per NEC 300.19 and 330.30 guidelines.

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. Reference NEC Article 330 for specific Metal-Clad installation guidelines.

Ampacity Note: Values calculated based on National Electrical Code (NEC) standards. Because most standard commercial electrical panels, breakers, and terminal lugs feature 75°C termination points, circuits are typically designed based on the conservative 180-Amp standard. The 205-Amp rating at 90°C is highly utilized for ampacity adjustment and correction factors.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4/0
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.82 in.
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600V
Ampacity Rating 205
Submersible No
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambeient temperature of 30°C (86°F).

Usage & Installation

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 1.35 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum Conductor Interlocked Armor MC Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, stranding and conductor material of the 6 AWG, 3 and 4 Conductor with Bare Ground Aluminum MC Cables.

4/0 4C Aluminum MC Cable with Bare Ground

Parent SKU :  MCA4/0-4

SKU :  MCA4/0-4-250

4 CONDUCTOR + GROUND • INTERLOCKING ARMOR • 600V • CUT TO LENGTH
In Stock
Ships in 1-2 days

Parent SKU :  MCA4/0-4

SKU :  MCA4/0-4-250

$2,512/ea.
$4,998/ea.
$9,945/ea.
$10.20/ft.
Please select an option
Min: 250 ft., Max: 20,000 ft.
Spool (250 ft.)
$2,512.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

"A dependable industrial and commercial choice for high-amperage 3-phase feeder systems, branch circuits, and secondary sub-panel installations requiring a neutral conductor. Engineered with a lightweight, interlocking aluminum armor jacket, this pre-protected 4-conductor plus ground assembly eliminates the extensive material and labor expenses of traditional conduit piping. It allows electrical crews to route heavy service lines directly through walls, ceilings, and open cable trays in a fraction of the time."

Key Features & Benefits: 4/0-4 Aluminum MC Cable w/ Ground

4/0 AWG 4-Conductor Aluminum Metal Clad (MC) Cable delivers a completely code-compliant, pre-armored wiring solution designed to minimize field labor hours and maximize jobsite efficiency. Featuring four compact-stranded AA-8000 series aluminum phase conductors insulated with cross-linked polyethylene (XLPE/XHHW-2) and a dedicated bare grounding wire, the assembly is protected by an overall interlocking aluminum armor jacket.

  • Labor-Saving Armor: The integrated aluminum interlocked armor serves as its own flexible metallic protective raceway, removing the tedious labor of bending and installing separate EMT or rigid conduit systems.

  • AA-8000 Conductor Material: Manufactured with compact-stranded 8000-series aluminum alloy to ensure high electrical conductivity, dramatically reduced weight strain during long structural pulls, and excellent flexibility.

  • XHHW-2 Insulation: Individual phase conductors are insulated with cross-linked polyethylene (XLPE), providing elite resistance to heat, moisture, and electrical stress in challenging industrial environments.

  • Maximum Versatility: Code-approved for an exceptionally broad range of heavy-duty installations including 3-phase commercial distribution panels, large equipment feeders, vertical risers, and environmental air-handling spaces (plenums).

  • Cut to Length or Bulk Spools: Order custom cut-to-length footage to eliminate jobsite waste, or select full factory spools and reels for major commercial installation pulls.

Technical Specifications: 4/0-4/0-4/0-4/0 Aluminum Metal Clad (MC) w/ Ground

  • Conductor Configuration: 4 Insulated Conductors + 1 Bare Ground Wire

  • Conductor Size: 4/0 AWG

  • Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (per ASTM B800 & B801)

  • Conductor Colors (240V): Black, White, Red, Blue 

  • Ground Wire Size: 2 AWG (Bare Stranded Aluminum)

  • Insulation: High-Heat & Moisture Resistant Cross-Linked Polyethylene (XLPE / Type XHHW-2). A binder tape is wrapped over the insulated conductors' assembly.

  • Armor: Overall Aluminum Interlocked Armor

  • Voltage Rating: 600 Volts

  • Temperature Rating: -40°C to 90°C

  • Amp Rating (@ 75°C - NEC): 180 Amps

  • Amp Rating (@ 90°C - NEC): 205 Amps

  • Insulation Thickness: 0.055 inches

  • Diameter Over Armor: 1.82 inches

  • Net Weight: 1,350 lbs per 1,000 ft

  • Minimum Bending Radius: 12.46 inches (Calculated as 7x Diameter Over Armor)

  • Compliance Standards: UL 44, UL 1569 for Type MC Cable (CT Use Rated), NEMA WC-70/ICEA S-95-658, IEEE 1202 70,000 BTU/HR Vertical Tray Flame Test, ASTM B800 & B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces (plenums).

Common 4/0 4-Conductor Alum MC Cable Applications

  • 175A–200A Sub-Panel Feeds: Primary 3-phase, 4-wire feeder lines running from main distribution switchboards to 175A or 200A sub-panels in office complexes, retail centers, and multi-tenant commercial spaces.

  • Heavy HVAC & Mechanical Systems: Direct power feeds for large rooftop HVAC units (RTUs), commercial chillers, air compressors, and refrigeration equipment requiring a dedicated neutral.

  • Open Plenum & Drop-Ceiling Routing: Fully certified under NEC 300.22 for routing directly through environmental air-handling plenum spaces, dropped ceiling voids, and raised floors without conduit.

  • Commercial EV Charging & Transformers: Reliable power distribution for high-output commercial EV charging hubs, battery backup systems, and 480V-to-208V step-down transformer connections.

  • Multi-Story Vertical Shafts: Approved for vertical riser shafts in multi-family residential and high-rise commercial structures when secured per NEC 300.19 and 330.30 guidelines.

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. Reference NEC Article 330 for specific Metal-Clad installation guidelines.

Ampacity Note: Values calculated based on National Electrical Code (NEC) standards. Because most standard commercial electrical panels, breakers, and terminal lugs feature 75°C termination points, circuits are typically designed based on the conservative 180-Amp standard. The 205-Amp rating at 90°C is highly utilized for ampacity adjustment and correction factors.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4/0
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.82 in.
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600V
Ampacity Rating 205
Submersible No
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambeient temperature of 30°C (86°F).

Usage & Installation

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 1.35 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum Conductor Interlocked Armor MC Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, stranding and conductor material of the 6 AWG, 3 and 4 Conductor with Bare Ground Aluminum MC Cables.

Physical Specifications

Wire Size (AWG/MCM) 4/0
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.82 in.
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600V
Ampacity Rating 205
Submersible No
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambeient temperature of 30°C (86°F).

Usage & Installation:

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 1.35 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

4/0 4C Aluminum MC Cable with Bare Ground is primarily used for 3-phase, 4-wire power distribution, feeders, and branch circuits in commercial and industrial facilities. The 4-conductor setup provides three hot phase conductors and a dedicated full-sized neutral, making it ideal for supplying power to 200A subpanels, 3-phase commercial equipment, and HVAC systems requiring neutral connections without conduit.

No. Standard 4/0 4C Aluminum MC cable with open, interlocked metal armor is engineered strictly for dry, indoor, concealed, or exposed installations. It cannot be buried directly in soil or embedded in concrete without a protective, fluid-tight PVC outer jacket (often designated as "Direct Burial MC" or "PVC-Jacketed MC"). For underground runs without conduit, a jacketed MC cable or direct-burial cable (like URD or USE-2) is required.

Yes! Wire America carries a full inventory of PVC-jacketed Direct Burial MC Cable. Standard bare-armor MC cable is rated exclusively for dry indoor or concealed locations. If your project involves underground trenching or wet outdoor locations, check out our 4/0 4-Conductor Direct Burial Aluminum MC Cable, which features a sunlight- and moisture-resistant PVC jacket extruded over the armor for direct earth burial without conduit.

The primary differences come down to weight, cost, and ampacity. Copper is a more efficient conductor, meaning 4/0 Copper MC is rated for 230 Amps (75°C), whereas 4/0 Aluminum MC is rated for 180 Amps (75°C). However, 4/0 Aluminum MC is dramatically lighter and significantly more cost-effective, making it the clear economic choice for long commercial feeder runs where a 180A capacity satisfies the electrical load.

Wire America supplies an extensive inventory of 4/0 4C Aluminum MC cable cut by the foot or on master reels. Most cut-to-length orders are processed and shipped within 24 to 48 hours, delivering directly to your shop or jobsite within 2 to 4 business days once in transit.

We route your order from the regional distribution hub with stock closest to your jobsite to keep transit times and freight costs as low as possible. Expedited shipping options are also available at checkout.

Working against a tight jobsite or inspection deadline? Call our team directly at 833-268-8644 to request priority processing!

Under National Electrical Code (NEC) guidelines, the allowable ampacity of 4/0 4C Aluminum MC Cable is 180 Amps @ 75°C and 205 Amps @ 90°C.

*Ampacities are based on NEC Table 310.16 for three current-carrying insulated conductors in a raceway or cable based on an ambient temperature of 30°C (86°F). Because standard equipment terminal lugs are rated at 75°C, most circuits are sized based on the 180-Amp rating. Note that if all four conductors are current-carrying (such as with major non-linear 3-phase loads), NEC ampacity derating factors (80%) may apply.

4/0 4C Aluminum MC Cable has an approximate physical net weight of 1,350 lbs per 1,000 feet (lbs/mft). The nominal outside diameter over the external interlocking aluminum armor is 1.78 inches (+/- 5%). Knowing these dimensions allows installers to select the appropriate trade-size connector fittings and evaluate structural weight strain for long cable tray pulls.

Do you need to use anti-oxidant joint compound with 4/0 aluminum MC conductors?

Yes, it is highly recommended. While modern AA-8000 series aluminum alloy is extremely stable, electrical best practice dictates applying an approved anti-oxidant paste (such as Noalox or Penetrox) onto stripped 4/0 aluminum conductor ends before securing them into mechanical lugs or breaker terminations. This prevents oxidation from forming a resistive film over the connection point, ensuring a long-lasting, cool-running termination.