6/3 w/ Ground Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Brown, Orange, Yellow, Green)

Parent SKU :  PPLEX6-3G-BOY

SKU :  PPLEX6-3G-BOY-250

XLPE INSULATED • 600/1000V • SUNLIGHT RESISTANT • FACTORY-TWISTED
Wire Size 6 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 0.64 in. / 16.3 mm
Conductor Count 3
Voltage Rating 600/1000V
Ampacity Rating 55
Weight per Foot 0.162 lb

Get Product Details

Get Product Details

This 6 AWG 3-conductor Priority-Plex® assembly is a highly efficient power distribution solution designed for commercial and industrial applications. Featuring aluminum XHHW-2 insulated conductors and a dedicated grounding conductor, this factory-twisted configuration is engineered to streamline installations in conduit by eliminating the need to pull individual wires on-site.

Why Choose Priority-Plex® 6 AWG Aluminum Feeder?

Priority-Plex® technology eliminates the traditional labor-intensive process of setting up multiple reels and straightening individual conductors. By twisting the Phase conductors (Brown, Orange, Yellow) and the Ground (Green) together at the factory, the bundle pulls more smoothly through conduit, significantly reducing the risk of "bird-caging" or jamming.

  • Labor Efficiency: Single-reel pull capability reduces setup time and requires fewer personnel on the job site.

  • XHHW-2 Insulation: Each conductor is insulated with Cross-linked Polyethylene (XLPE), providing excellent heat resistance, moisture protection, and high dielectric strength.

  • AA-8000 Aluminum Alloy: Constructed with lightweight, reliable 8000 series aluminum, offering a cost-effective alternative to copper without compromising safety or performance when properly terminated.

  • Instant Identification: Pre-colored conductors for 480V systems (Brown, Orange, Yellow) ensure easy phase identification, with a dedicated Green conductor for equipment grounding.

  • Thermal Resilience: Rated for continuous operation at 90°C in both wet and dry locations.

  • Lower Pulling Tension: The twisted geometry reduces the surface area contact against the conduit wall, allowing for easier pulls over long distances.

Technical Specifications: 6 AWG 3C w/ Ground

  • Phase Conductor Size: 6 AWG

  • Number of Phase Conductors: 3 (Brown, Orange, Yellow)

  • Grounding Conductor: 1 (6 AWG Green)

  • Conductor Material: AA-8000 Series Aluminum Alloy

  • Insulation Type: XHHW-2 (Cross-linked Polyethylene)

  • Voltage Rating: 600V

  • Temperature Rating: 90°C (Wet/Dry)

  • Configuration: Parallel-Twisted (Priority-Plex®)

Common Applications

  • Industrial Branch Circuits: Ideal for powering industrial machinery, HVAC units, and heavy-duty shop equipment.

  • Commercial Feeders: Used for sub-panel distribution in office buildings, warehouses, and retail centers.

  • Outdoor Installations: Rated for use in conduit in wet locations, making it suitable for wastewater facilities and parking lot lighting feeds.

  • Data Centers: Reliable power routing for localized cooling systems and server room infrastructure.


Technical Note: When working with aluminum conductors, installers must use listed compression or mechanical connectors rated specifically for aluminum (AL7CU or AL9CU) and apply an approved antioxidant joint compound to ensure long-term connection integrity.

Priority Part# 6-03PPLEX-BOY-6G

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.64 in. / 16.3 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 55
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.162 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

6/3 w/ Ground Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Brown, Orange, Yellow, Green)

Parent SKU :  PPLEX6-3G-BOY

SKU :  PPLEX6-3G-BOY-250

XLPE INSULATED • 600/1000V • SUNLIGHT RESISTANT • FACTORY-TWISTED
Contact us for price
Ships in 1-2 days

Parent SKU :  PPLEX6-3G-BOY

SKU :  PPLEX6-3G-BOY-250

$330/ea.
$657/ea.
$1,307/ea.
$3,250/ea.
$1.34/ft.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

This 6 AWG 3-conductor Priority-Plex® assembly is a highly efficient power distribution solution designed for commercial and industrial applications. Featuring aluminum XHHW-2 insulated conductors and a dedicated grounding conductor, this factory-twisted configuration is engineered to streamline installations in conduit by eliminating the need to pull individual wires on-site.

Why Choose Priority-Plex® 6 AWG Aluminum Feeder?

Priority-Plex® technology eliminates the traditional labor-intensive process of setting up multiple reels and straightening individual conductors. By twisting the Phase conductors (Brown, Orange, Yellow) and the Ground (Green) together at the factory, the bundle pulls more smoothly through conduit, significantly reducing the risk of "bird-caging" or jamming.

  • Labor Efficiency: Single-reel pull capability reduces setup time and requires fewer personnel on the job site.

  • XHHW-2 Insulation: Each conductor is insulated with Cross-linked Polyethylene (XLPE), providing excellent heat resistance, moisture protection, and high dielectric strength.

  • AA-8000 Aluminum Alloy: Constructed with lightweight, reliable 8000 series aluminum, offering a cost-effective alternative to copper without compromising safety or performance when properly terminated.

  • Instant Identification: Pre-colored conductors for 480V systems (Brown, Orange, Yellow) ensure easy phase identification, with a dedicated Green conductor for equipment grounding.

  • Thermal Resilience: Rated for continuous operation at 90°C in both wet and dry locations.

  • Lower Pulling Tension: The twisted geometry reduces the surface area contact against the conduit wall, allowing for easier pulls over long distances.

Technical Specifications: 6 AWG 3C w/ Ground

  • Phase Conductor Size: 6 AWG

  • Number of Phase Conductors: 3 (Brown, Orange, Yellow)

  • Grounding Conductor: 1 (6 AWG Green)

  • Conductor Material: AA-8000 Series Aluminum Alloy

  • Insulation Type: XHHW-2 (Cross-linked Polyethylene)

  • Voltage Rating: 600V

  • Temperature Rating: 90°C (Wet/Dry)

  • Configuration: Parallel-Twisted (Priority-Plex®)

Common Applications

  • Industrial Branch Circuits: Ideal for powering industrial machinery, HVAC units, and heavy-duty shop equipment.

  • Commercial Feeders: Used for sub-panel distribution in office buildings, warehouses, and retail centers.

  • Outdoor Installations: Rated for use in conduit in wet locations, making it suitable for wastewater facilities and parking lot lighting feeds.

  • Data Centers: Reliable power routing for localized cooling systems and server room infrastructure.


Technical Note: When working with aluminum conductors, installers must use listed compression or mechanical connectors rated specifically for aluminum (AL7CU or AL9CU) and apply an approved antioxidant joint compound to ensure long-term connection integrity.

Priority Part# 6-03PPLEX-BOY-6G

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.64 in. / 16.3 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 55
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.162 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.64 in. / 16.3 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 55
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation:

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.162 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us
AWG, or American Wire Gauge, is the standard system used primarily in North America to measure the diameter of electrical conductors. This system is critical because a wire's size directly impacts its electrical resistance and how much current (ampacity) it can safely carry. A key principle is that the smaller the AWG number, the larger the wire's diameter; for instance, 12 AWG is thicker and can carry more current than 14 AWG. Sizes beyond 0 AWG are referred to as "aught" (e.g., 1/0, 2/0). Selecting the correct AWG is essential for safe electrical installations, preventing overheating, and minimizing voltage drop.
Voltage drop is the natural reduction in electrical potential that occurs as current travels through a circuit, from the power source to a device. This happens because all wires inherently have resistance, which converts some electrical energy into heat, leading to a loss of voltage. While minor voltage drop is normal, excessive amounts can cause problems like dimming lights, slow or overheating motors, and erratic electronic behavior. It can also lead to higher energy consumption and, in severe cases, create safety hazards due to overheating wires. Key factors influencing voltage drop include the wire's length and thickness (gauge), the amount of current flowing through it, and the quality of electrical connections.
In electrical wiring, amps (amperes) measure the rate of electrical current flow. Think of it as the volume of electricity moving through the wire at any given time. Crucially, every electrical wire has an ampacity rating, which is the maximum current it can safely carry continuously without overheating. Exceeding a wire's ampacity can lead to insulation damage and fire hazards, highlighting why proper wire sizing based on expected amperage is vital for safe electrical systems.
A wire's ampacity, or its safe current-carrying capacity, changes with temperature primarily because of two factors. First, the electrical resistance of copper and aluminum wires increases as they get hotter, causing them to generate more heat when current flows. Second, every wire's insulation has a maximum temperature limit; exceeding this can cause degradation and safety hazards. Therefore, in hotter environments, a wire must carry less current to avoid exceeding its insulation's temperature rating. This ensures the wire remains safe and functional, preventing overheating and potential failures.
We aim to provide authentic, precise images of each wire; however, with various product variations, it can be challenging. In such instances, we focus on showcasing the fundamental design. Always refer to the product specifications rather than relying solely on images.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us