3/0-3/0-3/0 SEU Aluminum Service Entrance Cable

Parent SKU :  ALSEU3/0-2G

SKU :  ALSEU3/0-2G-100

XLP INSULATED • SUNLIGHT RESISTANT • CUT TO LENGTH
Wire Size 3/0
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 0.826 x 1.358 in.
Conductor Count 2
Voltage Rating 600V
Ampacity Rating 175

Get Product Details

Get Product Details

An economical, flat-profile service entrance cable engineered to convey power from the service drop to the meter base, from the meter base to the main distribution panelboard, and for code-permitted interior branch circuits. Constructed with compact stranded 8000-series aluminum alloy conductors, this 3/0-3/0-3/0 SEU Cable features two insulated 3/0 AWG 19-strand conductors surrounded by a full-size 14-strand concentric bare 3/0 AWG aluminum neutral/ground and encased in a durable, sunlight-resistant gray PVC outer jacket.

Engineered for 175A Service Drops, Meter Loops & Permitted Branch Circuits

Built to meet rigorous National Electrical Code (NEC) standards for above-ground service entrance and interior branch circuit wiring, this Type SE Style U (SEU) cable pairs Type XHHW-2 cross-linked polyethylene (XLPE) insulated conductors with a concentrically applied neutral, binder tape, and rugged polyvinyl chloride sheath.

  • 600V Rated Performance: Approved for 600-volt power distribution across wet or dry locations up to a maximum conductor operating temperature of 90°C.

  • Flat Oval Profile with Full-Size Concentric Neutral: Two 19-strand 3/0 AWG insulated phase conductors (black and red) are wrapped in a full-size 14-strand bare 3/0 AWG concentric neutral/ground and binder tape for a compact 0.826" x 1.358" flat profile that routes cleanly along exterior siding, through weatherhead bushings, and into meter sockets.

  • Compact Stranded AA-8000 Aluminum: Engineered with compact stranded soft-drawn 8000-series aluminum alloy per ASTM B-800 and B-801 for easier bending, smoother pulling, and reliable mechanical termination stability.

  • Sunlight-Resistant Outer Jacket: Heavy-duty gray PVC sheath protects internal conductors against UV degradation, moisture, and jobsite abrasion during exterior and interior installation.

  • Code-Compliant Construction: Fully listed to UL 44, UL 854, Federal Specification J-C-30B, and National Electric Code (NEC Article 338) for above-ground service entrance and permitted branch circuits.

Technical Specifications: 3/0-3/0-3/0 Aluminum SEU Cable

  • Conductor Size: 3/0 AWG (Phase Conductors) / 3/0 AWG (Full-Size Bare Concentric Neutral/Ground)

  • Number of Conductors: 2 Insulated Conductors (3/0 AWG) + 1 Bare Concentric Neutral/Ground (3/0 AWG)

  • Conductor Material: Compact Stranded Soft-Drawn 8000 Series Aluminum Alloy

  • Number of Strands: 19 Strands (3/0 AWG Insulated) / 14 Strands (3/0 AWG Bare Concentric Neutral)

  • Conductor Insulation: Type XHHW-2 Cross-Linked Polyethylene (XLPE)

  • Conductor Color Code: Solid Colored Black and Red (with Bare Concentric Neutral)

  • Assembly: Phase conductors surrounded by a concentrically applied neutral and binder tape

  • Outer Jacket: Gray Sunlight-Resistant Polyvinyl Chloride (PVC)

  • Nominal Outside Diameter (OD): 826 x 1358 mils (0.826" x 1.358")

  • Approximate Net Weight: 623 lbs / kft

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C (Wet or Dry Locations)

  • Allowable Ampacity: 130 Amps @ 60°C | 155 Amps @ 75°C | 175 Amps @ 90°C (175 Amps Dwelling)*

  • Industry Standards & Listings: UL 44 (Thermoset-Insulated Wires and Cables), UL 854 (Standard for Service-Entrance Cables), ASTM B-800, B-801, Federal Specifications J-C-30B, National Electric Code (NEC Article 338)

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and correction. Buyers must verify project and local electrical code compliance.

*Ampacities shown are for general use as specified by the National Electrical Code (NEC), 2023 Edition, Table 310.16 & Article 338.10. For dwelling, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service and feeder conductors that serve as the main feeder per NEC article 310.12.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 3/0
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.826 x 1.358 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 175
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44: Thermoset-Insulated Wires and Cables
UL 854: Standard for Service-Entrance Cables
ASTM B-800, B-801
Federal Specifications J-C-30B
National Electric Code
Miscellaneous Information All values are nominal and subject to correction. **Ampacities shown are for general use as specified by the National Electrical Code, 2023 Edition Table 310.16 & article 338.10. For dwelling, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service and feeder conductors that serve as the main feeder per NEC article 310.12.

Usage & Installation

Primary ApplicationsPanel Feeder Cable
Common Uses
  • Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.623 lb

Real World Applications

Real World Applications

  • 175-Amp Residential Service Drops & Meter Loops: Conveying 120/240V single-phase power from the overhead utility weatherhead down to the exterior meter base and into a 175A main service disconnect—delivering full 175A dwelling service capacity under NEC Article 310.12 where utility or AHJ rules call for a full-size 3/0 AWG neutral (623 lbs/kft).
  • Dedicated 240V Heavy Residential & Commercial Branch Circuits: Pulling flat-profile 3/0-3/0-3/0 SEU through framing to supply dedicated 130A–155A straight-240V equipment, such as large multi-stage electric furnaces, whole-house tankless water heating systems, or commercial shop machinery.
  • Mobile Home & Outbuilding Main Service Loops: Installing between exterior meter pedestals and 175A main disconnects where bonded neutral-to-ground service entrance rules apply and a full-size neutral/ground conductor is specified.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum SEU Service Entrance Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 6-6-6 Aluminum Service Entrance Cable, SEU.

3/0-3/0-3/0 SEU Aluminum Service Entrance Cable

Parent SKU :  ALSEU3/0-2G

SKU :  ALSEU3/0-2G-100

XLP INSULATED • SUNLIGHT RESISTANT • CUT TO LENGTH
Contact us for price
Ships in 1-2 days

Parent SKU :  ALSEU3/0-2G

SKU :  ALSEU3/0-2G-100

$0/ea.
$0/ea.
$0/ea.
$0/ea.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

An economical, flat-profile service entrance cable engineered to convey power from the service drop to the meter base, from the meter base to the main distribution panelboard, and for code-permitted interior branch circuits. Constructed with compact stranded 8000-series aluminum alloy conductors, this 3/0-3/0-3/0 SEU Cable features two insulated 3/0 AWG 19-strand conductors surrounded by a full-size 14-strand concentric bare 3/0 AWG aluminum neutral/ground and encased in a durable, sunlight-resistant gray PVC outer jacket.

Engineered for 175A Service Drops, Meter Loops & Permitted Branch Circuits

Built to meet rigorous National Electrical Code (NEC) standards for above-ground service entrance and interior branch circuit wiring, this Type SE Style U (SEU) cable pairs Type XHHW-2 cross-linked polyethylene (XLPE) insulated conductors with a concentrically applied neutral, binder tape, and rugged polyvinyl chloride sheath.

  • 600V Rated Performance: Approved for 600-volt power distribution across wet or dry locations up to a maximum conductor operating temperature of 90°C.

  • Flat Oval Profile with Full-Size Concentric Neutral: Two 19-strand 3/0 AWG insulated phase conductors (black and red) are wrapped in a full-size 14-strand bare 3/0 AWG concentric neutral/ground and binder tape for a compact 0.826" x 1.358" flat profile that routes cleanly along exterior siding, through weatherhead bushings, and into meter sockets.

  • Compact Stranded AA-8000 Aluminum: Engineered with compact stranded soft-drawn 8000-series aluminum alloy per ASTM B-800 and B-801 for easier bending, smoother pulling, and reliable mechanical termination stability.

  • Sunlight-Resistant Outer Jacket: Heavy-duty gray PVC sheath protects internal conductors against UV degradation, moisture, and jobsite abrasion during exterior and interior installation.

  • Code-Compliant Construction: Fully listed to UL 44, UL 854, Federal Specification J-C-30B, and National Electric Code (NEC Article 338) for above-ground service entrance and permitted branch circuits.

Technical Specifications: 3/0-3/0-3/0 Aluminum SEU Cable

  • Conductor Size: 3/0 AWG (Phase Conductors) / 3/0 AWG (Full-Size Bare Concentric Neutral/Ground)

  • Number of Conductors: 2 Insulated Conductors (3/0 AWG) + 1 Bare Concentric Neutral/Ground (3/0 AWG)

  • Conductor Material: Compact Stranded Soft-Drawn 8000 Series Aluminum Alloy

  • Number of Strands: 19 Strands (3/0 AWG Insulated) / 14 Strands (3/0 AWG Bare Concentric Neutral)

  • Conductor Insulation: Type XHHW-2 Cross-Linked Polyethylene (XLPE)

  • Conductor Color Code: Solid Colored Black and Red (with Bare Concentric Neutral)

  • Assembly: Phase conductors surrounded by a concentrically applied neutral and binder tape

  • Outer Jacket: Gray Sunlight-Resistant Polyvinyl Chloride (PVC)

  • Nominal Outside Diameter (OD): 826 x 1358 mils (0.826" x 1.358")

  • Approximate Net Weight: 623 lbs / kft

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C (Wet or Dry Locations)

  • Allowable Ampacity: 130 Amps @ 60°C | 155 Amps @ 75°C | 175 Amps @ 90°C (175 Amps Dwelling)*

  • Industry Standards & Listings: UL 44 (Thermoset-Insulated Wires and Cables), UL 854 (Standard for Service-Entrance Cables), ASTM B-800, B-801, Federal Specifications J-C-30B, National Electric Code (NEC Article 338)

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and correction. Buyers must verify project and local electrical code compliance.

*Ampacities shown are for general use as specified by the National Electrical Code (NEC), 2023 Edition, Table 310.16 & Article 338.10. For dwelling, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service and feeder conductors that serve as the main feeder per NEC article 310.12.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 3/0
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.826 x 1.358 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 175
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44: Thermoset-Insulated Wires and Cables
UL 854: Standard for Service-Entrance Cables
ASTM B-800, B-801
Federal Specifications J-C-30B
National Electric Code
Miscellaneous Information All values are nominal and subject to correction. **Ampacities shown are for general use as specified by the National Electrical Code, 2023 Edition Table 310.16 & article 338.10. For dwelling, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service and feeder conductors that serve as the main feeder per NEC article 310.12.

Usage & Installation

Primary ApplicationsPanel Feeder Cable
Common Uses
  • Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.623 lb

Real World Applications

Real World Applications

  • 175-Amp Residential Service Drops & Meter Loops: Conveying 120/240V single-phase power from the overhead utility weatherhead down to the exterior meter base and into a 175A main service disconnect—delivering full 175A dwelling service capacity under NEC Article 310.12 where utility or AHJ rules call for a full-size 3/0 AWG neutral (623 lbs/kft).
  • Dedicated 240V Heavy Residential & Commercial Branch Circuits: Pulling flat-profile 3/0-3/0-3/0 SEU through framing to supply dedicated 130A–155A straight-240V equipment, such as large multi-stage electric furnaces, whole-house tankless water heating systems, or commercial shop machinery.
  • Mobile Home & Outbuilding Main Service Loops: Installing between exterior meter pedestals and 175A main disconnects where bonded neutral-to-ground service entrance rules apply and a full-size neutral/ground conductor is specified.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum SEU Service Entrance Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 6-6-6 Aluminum Service Entrance Cable, SEU.

Physical Specifications

Wire Size (AWG/MCM) 3/0
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 0.826 x 1.358 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 175
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44: Thermoset-Insulated Wires and Cables
UL 854: Standard for Service-Entrance Cables
ASTM B-800, B-801
Federal Specifications J-C-30B
National Electric Code
Miscellaneous Information All values are nominal and subject to correction. **Ampacities shown are for general use as specified by the National Electrical Code, 2023 Edition Table 310.16 & article 338.10. For dwelling, conductors shall be permitted at listed ampacities to be utilized as 120/240 volt, 3-wire, single-phase service and feeder conductors that serve as the main feeder per NEC article 310.12.

Usage & Installation:

Primary ApplicationsPanel Feeder Cable
Common Uses
  • Branch Circuits

Packaging & Dimensions:

Weight per Foot 0.623 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

3/0-3/0-3/0 Aluminum SEU Cable (Service Entrance Style U) is a 600V flat-oval multi-conductor cable consisting of two 19-strand 3/0 AWG insulated conductors (black and red) wrapped inside a full-size 14-strand bare 3/0 AWG concentric neutral/ground conductor. It is primarily used for above-ground 175-amp residential service entrance drops requiring a full-size neutral, meter-to-main-panel connections, and code-permitted 130A–155A 240V branch circuits. (Note: If you are feeding a downstream subpanel that requires an isolated neutral and equipment ground, use 4-conductor Aluminum SER cable instead.)

Per NEC Table 310.16 and Article 338.10, 3/0 AWG aluminum SEU Cable conductors are rated for 130 Amps at 60°C, 155 Amps at 75°C, and 175 Amps at 90°C. When used as the main service entrance or feeder carrying the entire load of an individual 120/240V dwelling unit, NEC Article 310.12 permits a 175-Amp rating.

Important NEC Note: Per NEC 338.10(B)(4)(a), interior SEU cable installed in thermal insulation or branch circuits is limited to the 60°C rating (130 Amps), except where permitted for main dwelling feeders under NEC Article 310.12. Always verify breaker sizing and local code compliance with a licensed electrician or AHJ before installation.

3/0-3/0-3/0 SEU is rated for 155 Amps at 75°C and 175 Amps for dwelling main services (623 lbs/kft, 0.826" x 1.358" OD), making it ideal for 150A–175A service upgrades. 4/0-4/0-4/0 SEU steps up to 180 Amps at 75°C and 200 Amps for dwelling main services (764 lbs/kft, 0.878" x 1.462" OD), which is the standard choice for full 200-amp residential service entrances.

SEU (Service Entrance Style U) is a flat-oval cable featuring two insulated conductors wrapped in a bare concentric neutral/ground ribbon, designed primarily for service drops, meter loops, and straight-240V branch circuits. SER (Service Entrance Style R) is a round cable assembly containing insulated conductors cabled around a separate bare equipment grounding conductor, designed for interior panel feeders where an isolated neutral and ground are required.

No. Type SEU Cable is listed under UL 854 for above-ground installation only. While its XHHW-2 internal conductors and gray PVC outer jacket are rated for wet and sunlight-resistant exterior locations, SEU is not rated for direct burial or underground conduit installations. For underground runs, use Aluminum URD or USE-2 / RHH / RHW-2 conductors.

Wire America stocks master reels of AA-8000 Aluminum SEU Cable ready for rapid commercial, multi-family, and residential jobsite fulfillment:

  • Custom Cut-to-Length Spools: Order the exact footage needed for your pull schedule to eliminate costly jobsite scrap.
  • Fast Nationwide Shipping: Rapid shipping from regional distribution hubs to keep service upgrade and residential rough-in schedules on track.
  • Expert Technical Support: Direct access to knowledgeable wire and cable specialists for instant submittal sheets, UL 44 / UL 854 verification, and project takeoff requirements.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us