250 MCM Aluminum XLP/USE-2 RHW-2/RHH Direct Burial Wire

Parent SKU :  XUSEAL250

SKU :  XUSEAL250-250

600V • XLP INSULATION • SUNLIGHT RESISTANT • CUT TO LENGTH
Wire Size 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 0.713 in. / 18.110 mm
Conductor Count 1
Voltage Rating 600V
Ampacity Rating 230
Weight per Foot 0.326 lb

Get Product Details

Get Product Details

A heavy-duty 250 MCM single-conductor aluminum building wire engineered for underground service entrance feeds, direct burial power distribution, raceways, and branch circuits. Constructed with compact 8000 series aluminum alloy and wrapped in rugged cross-linked polyethylene (XLP) insulation, this 600V triple-rated cable (Direct Burial, Sunlight Resistant & Oil/Gas Resistant) provides extreme resistance to mechanical abrasion, moisture, and chemical exposure in harsh wet or dry environments.

Engineered for Direct Burial, Underground Service Entrance, and Conduit Runs

When routing power below grade, into main service panels, or through exterior raceways, long-term environmental protection is essential. 250 kcmil USE-2 aluminum wire balances high current-carrying capacity with lightweight, flexible handling compared to equivalent copper conductors. Featuring compact Class B stranding and heavy-duty XLP insulation, it pulls smoothly through conduits and survives direct earth trenching without requiring a protective outer jacket.

  • Triple-Rated Versatility (RHH/RHW-2/USE-2): Multi-listed for underground service entrance (USE-2), wet-location thermal endurance (RHW-2), and dry-location high-heat applications (RHH).

  • Direct Burial Certified: Heavy XLP insulation permits direct underground trenching for commercial service feeds, agricultural infrastructure, and subterranean subpanel runs without conduit.

  • Compact 8000 Series Aluminum: Formulated with AA-8000 series aluminum alloy for maximum electrical conductivity, improved terminal connection reliability, and lightweight installation compared to copper.

  • Environmental Resistance: Fully rated as sunlight resistant, oil resistant (PRI/PRII), and gas/oil resistant (GRI/GRII) for industrial and petroleum-exposed environments.

Technical Specifications

  • Conductor Size: 250 kcmil (MCM)

  • Conductor Material: Class B Stranded Compact Bare 8000 Series Aluminum Alloy

  • Conductor Diameter: 0.520" (13.21 mm)

  • Insulation Material: Abrasion, heat, and moisture-resistant Cross-Linked Polyethylene (XLP)

  • Insulation Thickness: 0.095" (2.41 mm)

  • Nominal Overall Diameter: 0.713" (18.11 mm)

  • Net Weight: 326 lbs / kft

  • Ampacity: 230 Amps @ 90°C (NEC Table 310.16; 205 Amps @ 75°C termination rating)

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C Wet or Dry

  • Industry Designation: 250 kcmil 1C AL RHH/RHW-2/USE-2 600V XLP

  • UL Listings & Code Approvals: UL 44, UL 854, NEMA WC 70/ICEA S-95-658, ASTM B800, ASTM B801, ASTM B836, NEC Requirements, RUS Accepted, Sunlight Resistant, Oil Resistant PRI/PRII, Gas & Oil Resistant GRI/GRII

Common Applications

  • Underground Service Entrance (USE-2): Approved for underground service utility feeds running directly from transformers or pedestals to main service equipment.

  • Direct Burial & Trenching: Certified for direct earth burial without protective conduit for subpanel feeds, commercial outbuildings, and heavy power distribution equipment.

  • Conduit & Raceway Wiring: Suitable for installation in underground and above-ground rigid conduit, PVC, and raceways per National Electrical Code guidelines.

  • Agricultural & Industrial Feeds: RUS Accepted and oil/gas resistant for agricultural facilities, livestock barns, fuel yards, and industrial plant infrastructure.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, NEC, and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.713 in. / 18.110 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 230
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 854
NEMA WC 70/ICEA S-95-658
Requirements of the NEC
ASTM B800, B801, B836
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Ampacities shown are for general use as specified by the National Electrical Code 2023 Edition section 310.16

Usage & Installation

Primary ApplicationsUnderground Service Entrance, General Purpose Building Wire, Raceways and Conduits, Wet or Dry Locations, Aerial Installations, Photovoltaic (Solar) Systems, Demanding Conditions.

Packaging & Dimensions:

Weight per Foot 0.326 lb

Real World Applications

Real World Applications

  • 200A Commercial & High-Capacity Service Entrances: Serving as high-capacity direct-buried service lateral feeders for 200A commercial disconnects where long runs require sizing up to minimize voltage drop.
  • Main Commercial Subpanel & Feeder Runs: Supplying underground power distribution to large 200A or 225A main subpanels across commercial properties, industrial parks, and multi-building complexes.
  • Commercial DC Fast-Charging Infrastructure: Routing direct-buried underground power feeds or conduit runs to high-output EV fast-charging pedestals and fleet hub distribution centers.
  • Heavy Industrial & Agricultural Machinery: Feeding primary power disconnects for large grain elevator networks, heavy processing machinery, and primary agricultural disconnect switches.
  • Utility Meter & Service Drops: Routing underground service conductors from utility pedestals to building disconnect switches where permitted by local AHJ.

Disclaimer: Application examples are for planning purposes only. Always verify exact load calculations, local AHJ regulations, and NEC guidelines with a licensed electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum XLP/USE-2/RHH/RHW-2 Building Wire

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 4/0 XLP/USE-2/RHH/RHW-2 Aluminum Building Wire.

250 MCM Aluminum XLP/USE-2 RHW-2/RHH Direct Burial Wire

Parent SKU :  XUSEAL250

SKU :  XUSEAL250-250

600V • XLP INSULATION • SUNLIGHT RESISTANT • CUT TO LENGTH
In Stock
Ships in 1-2 days

Parent SKU :  XUSEAL250

SKU :  XUSEAL250-250

$481/ea.
$956/ea.
$1,902/ea.
$2.15/ft.
Please select an option
Min: 250 ft., Max: 20,000 ft.
Spool (250 ft.)
$481.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A heavy-duty 250 MCM single-conductor aluminum building wire engineered for underground service entrance feeds, direct burial power distribution, raceways, and branch circuits. Constructed with compact 8000 series aluminum alloy and wrapped in rugged cross-linked polyethylene (XLP) insulation, this 600V triple-rated cable (Direct Burial, Sunlight Resistant & Oil/Gas Resistant) provides extreme resistance to mechanical abrasion, moisture, and chemical exposure in harsh wet or dry environments.

Engineered for Direct Burial, Underground Service Entrance, and Conduit Runs

When routing power below grade, into main service panels, or through exterior raceways, long-term environmental protection is essential. 250 kcmil USE-2 aluminum wire balances high current-carrying capacity with lightweight, flexible handling compared to equivalent copper conductors. Featuring compact Class B stranding and heavy-duty XLP insulation, it pulls smoothly through conduits and survives direct earth trenching without requiring a protective outer jacket.

  • Triple-Rated Versatility (RHH/RHW-2/USE-2): Multi-listed for underground service entrance (USE-2), wet-location thermal endurance (RHW-2), and dry-location high-heat applications (RHH).

  • Direct Burial Certified: Heavy XLP insulation permits direct underground trenching for commercial service feeds, agricultural infrastructure, and subterranean subpanel runs without conduit.

  • Compact 8000 Series Aluminum: Formulated with AA-8000 series aluminum alloy for maximum electrical conductivity, improved terminal connection reliability, and lightweight installation compared to copper.

  • Environmental Resistance: Fully rated as sunlight resistant, oil resistant (PRI/PRII), and gas/oil resistant (GRI/GRII) for industrial and petroleum-exposed environments.

Technical Specifications

  • Conductor Size: 250 kcmil (MCM)

  • Conductor Material: Class B Stranded Compact Bare 8000 Series Aluminum Alloy

  • Conductor Diameter: 0.520" (13.21 mm)

  • Insulation Material: Abrasion, heat, and moisture-resistant Cross-Linked Polyethylene (XLP)

  • Insulation Thickness: 0.095" (2.41 mm)

  • Nominal Overall Diameter: 0.713" (18.11 mm)

  • Net Weight: 326 lbs / kft

  • Ampacity: 230 Amps @ 90°C (NEC Table 310.16; 205 Amps @ 75°C termination rating)

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C Wet or Dry

  • Industry Designation: 250 kcmil 1C AL RHH/RHW-2/USE-2 600V XLP

  • UL Listings & Code Approvals: UL 44, UL 854, NEMA WC 70/ICEA S-95-658, ASTM B800, ASTM B801, ASTM B836, NEC Requirements, RUS Accepted, Sunlight Resistant, Oil Resistant PRI/PRII, Gas & Oil Resistant GRI/GRII

Common Applications

  • Underground Service Entrance (USE-2): Approved for underground service utility feeds running directly from transformers or pedestals to main service equipment.

  • Direct Burial & Trenching: Certified for direct earth burial without protective conduit for subpanel feeds, commercial outbuildings, and heavy power distribution equipment.

  • Conduit & Raceway Wiring: Suitable for installation in underground and above-ground rigid conduit, PVC, and raceways per National Electrical Code guidelines.

  • Agricultural & Industrial Feeds: RUS Accepted and oil/gas resistant for agricultural facilities, livestock barns, fuel yards, and industrial plant infrastructure.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, NEC, and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.713 in. / 18.110 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 230
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 854
NEMA WC 70/ICEA S-95-658
Requirements of the NEC
ASTM B800, B801, B836
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Ampacities shown are for general use as specified by the National Electrical Code 2023 Edition section 310.16

Usage & Installation

Primary ApplicationsUnderground Service Entrance, General Purpose Building Wire, Raceways and Conduits, Wet or Dry Locations, Aerial Installations, Photovoltaic (Solar) Systems, Demanding Conditions.

Packaging & Dimensions:

Weight per Foot 0.326 lb

Real World Applications

Real World Applications

  • 200A Commercial & High-Capacity Service Entrances: Serving as high-capacity direct-buried service lateral feeders for 200A commercial disconnects where long runs require sizing up to minimize voltage drop.
  • Main Commercial Subpanel & Feeder Runs: Supplying underground power distribution to large 200A or 225A main subpanels across commercial properties, industrial parks, and multi-building complexes.
  • Commercial DC Fast-Charging Infrastructure: Routing direct-buried underground power feeds or conduit runs to high-output EV fast-charging pedestals and fleet hub distribution centers.
  • Heavy Industrial & Agricultural Machinery: Feeding primary power disconnects for large grain elevator networks, heavy processing machinery, and primary agricultural disconnect switches.
  • Utility Meter & Service Drops: Routing underground service conductors from utility pedestals to building disconnect switches where permitted by local AHJ.

Disclaimer: Application examples are for planning purposes only. Always verify exact load calculations, local AHJ regulations, and NEC guidelines with a licensed electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum XLP/USE-2/RHH/RHW-2 Building Wire

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 4/0 XLP/USE-2/RHH/RHW-2 Aluminum Building Wire.

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.713 in. / 18.110 mm
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 854

Technical Specifications

Voltage Rating 600V
Ampacity Rating 230
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44
UL 854
NEMA WC 70/ICEA S-95-658
Requirements of the NEC
ASTM B800, B801, B836
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Ampacities shown are for general use as specified by the National Electrical Code 2023 Edition section 310.16

Usage & Installation:

Primary ApplicationsUnderground Service Entrance, General Purpose Building Wire, Raceways and Conduits, Wet or Dry Locations, Aerial Installations, Photovoltaic (Solar) Systems, Demanding Conditions.

Packaging & Dimensions:

Weight per Foot 0.326 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

250 MCM (kcmil) Aluminum USE-2 / RHW-2 building wire is designed for direct burial power distribution, underground service entrance feeds, and branch circuits running through conduit. It is commonly used to supply main electrical service to residential panels, large subpanels, agricultural operations, and commercial infrastructure.

This wire carries three distinct UL listings for maximum versatility:

  • USE-2: Rated for direct burial and underground utility feeds (90°C wet/dry).
  • RHW-2: Rated for installation in conduit and wet locations up to 90°C.
  • RHH: Rated for installation in raceways in dry locations at high temperatures (90°C).

Yes, absolutely. The rugged cross-linked polyethylene (XLP/XLPE) insulation is engineered to withstand soil moisture, earth pressure, abrasion, and direct chemical exposure without requiring a conduit sleeve.

Yes. The black XLP insulation compound is explicitly listed as Sunlight Resistant, preventing UV degradation, cracking, or breakdown when exposed to direct sunlight above ground.

No. Per the National Electrical Code and UL standards, single-conductor USE-2 wire is explicitly not rated for use in cable trays. If your installation requires a multi-conductor cable approved for tray installations, raceways, or direct burial overhead feeds, view our 250-3C Aluminum Tray Cable (XLP/PVC).

Yes. When terminating 8000 series aluminum wire, always clean the bare conductor strands, apply a listed antioxidant joint compound (de-ox) to prevent oxidation, and tighten lugs to the manufacturer's specified torque rating using AL7CU or AL9CU dual-rated connectors.

Yes. If your electrical panel terminals or equipment disconnects are rated for copper conductors only, or if you need higher current-carrying capacity (290A @ 90°C) in a 250 kcmil size, view our 250 kcmil Copper USE-2 / RHW-2 / RHH Building Wire. Copper conductors provide higher conductivity and smaller conduit fill footprints compared to aluminum.

Wire America supplies premium aluminum building wire directly to electrical contractors, utilities, agricultural operations, and industrial builders. When you source through us, you get:

  • Direct Technical & Order Support: Real wire and cable specialists ready to assist with product specifications, ampacity data, conduit fill sizing, and custom quotes.
  • Fast Job-Site Shipping: Direct dispatch from strategic distribution hubs gets material directly to your shop, facility, or job site on schedule.
  • Cut-by-The-Foot Lengths: Order the exact footage required for your underground runs to eliminate job-site scrap, unnecessary material costs, and spool waste.
  • Bulk Master Spools Available: Full factory spools and master reels in stock for utility builds, commercial projects, and large facility distribution.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us