14/2 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  14-2TECK90

SKU :  14-2TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Wire Size 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter 0.67 in. / 17.02 mm
Conductor Count 2
Voltage Rating 600V
Ampacity Rating 25
Weight per Foot 0.195 lb

Get Product Details

Get Product Details

A rugged, two-conductor armored power, lighting, and control cable engineered for heavy industrial facilities, chemical plants, pulp and paper mills, steel mills, mines, power generating stations, and commercial centers. Featuring two 14 AWG bare copper circuit conductors and an uninsulated bare copper grounding conductor, this cable is protected by a continuous Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and operating temperatures from -40°C to +90°C, it provides exceptional crush resistance, physical defense, and full environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running single-phase power, lighting branch circuits, or discrete 2-wire control loops through corrosive atmospheres, physical abuse zones, or sub-zero northern climates, structural reliability ensures continuous uptime. The 14/2 TECK90 Cable eliminates the high material cost, rigid bending limitations, and pull-labor of traditional conduit-and-wire installations. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands heavy mechanical impact, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous mechanical shielding and impact protection while preserving cable flexibility for complex routing around structural steel and machinery frames.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC jacket under the armor and a heavy-duty -40°C outer PVC jacket that defends against water ingress, chemical washdowns, sunlight (UV), and outer abrasion.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation maintains dielectric strength up to 90°C and eliminates conductor deformation or insulation flow during thermal spikes.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, allowing cold-weather installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame tests (70,000 BTU/hr), preventing vertical fire propagation along industrial tray runs.

Technical Specifications

  • Conductor Size: 14 AWG

  • Number of Conductors: 2 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black, White

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.58 inches (14.73 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.67 inches (17.02 mm)

  • Approximate Net Weight: 195 lbs / kft (290 kg/km)

  • Ampacity: 25 Amps (Based on CE Code Part 1, Table 2 for raceway/cable)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 14/2C W/GND AIA TECK90 600V RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Industrial Lighting Circuits: Supplying 120V or 277V single-phase industrial plant lighting fixtures, high-bay luminaires, and perimeter floodlights.

  • Control & Interlock Loops: 2-wire discrete control runs between pushbuttons, limit switches, solenoids, and PLC input cards.

  • Chemical & Processing Plants: Single-phase power and control circuits routed through corrosive process areas, compressor sheds, and pump galleries.

  • Direct Burial & Trench Runs: Installing power runs directly underground between buildings, outbuildings, outdoor gate operators, and perimeter bollards without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.


See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.67 in. / 17.02 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 25
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.195 lb

Real World Applications

Real World Applications

  • Plant Lighting Feeds: Connecting high-bay industrial lighting fixtures in pulp mills, steel plants, and mining crushers where ambient dust and physical vibration compromise unarmored cables.
  • Field Solenoid & Actuator Drops: Powering 120V AC or 24V DC discrete pneumatic solenoid valves, flow switches, and electric valve actuators in processing skids.
  • Outdoor Perimeter & Site Power: Direct-burial feeds running from main facility breaker panels to remote gate operators, outdoor light poles, and cathodic protection units.
  • Conveyor Interlock & Pull-Cord Switches: Wiring emergency stop pull cords and alignment switches along open-air bulk material handling conveyors.
  • Wastewater Wet Wells & Basins: Routing auxiliary 120V circuits in damp, hydrogen-sulfide-rich environments where standard metallic conduit quickly corrodes.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

14/2 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  14-2TECK90

SKU :  14-2TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Contact us for price
Ships in 1-2 days

Parent SKU :  14-2TECK90

SKU :  14-2TECK90-250

$412/ea.
$819/ea.
$1,629/ea.
$4,050/ea.
$8,058/ea.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A rugged, two-conductor armored power, lighting, and control cable engineered for heavy industrial facilities, chemical plants, pulp and paper mills, steel mills, mines, power generating stations, and commercial centers. Featuring two 14 AWG bare copper circuit conductors and an uninsulated bare copper grounding conductor, this cable is protected by a continuous Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and operating temperatures from -40°C to +90°C, it provides exceptional crush resistance, physical defense, and full environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running single-phase power, lighting branch circuits, or discrete 2-wire control loops through corrosive atmospheres, physical abuse zones, or sub-zero northern climates, structural reliability ensures continuous uptime. The 14/2 TECK90 Cable eliminates the high material cost, rigid bending limitations, and pull-labor of traditional conduit-and-wire installations. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands heavy mechanical impact, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous mechanical shielding and impact protection while preserving cable flexibility for complex routing around structural steel and machinery frames.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC jacket under the armor and a heavy-duty -40°C outer PVC jacket that defends against water ingress, chemical washdowns, sunlight (UV), and outer abrasion.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation maintains dielectric strength up to 90°C and eliminates conductor deformation or insulation flow during thermal spikes.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, allowing cold-weather installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame tests (70,000 BTU/hr), preventing vertical fire propagation along industrial tray runs.

Technical Specifications

  • Conductor Size: 14 AWG

  • Number of Conductors: 2 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black, White

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.58 inches (14.73 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.67 inches (17.02 mm)

  • Approximate Net Weight: 195 lbs / kft (290 kg/km)

  • Ampacity: 25 Amps (Based on CE Code Part 1, Table 2 for raceway/cable)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 14/2C W/GND AIA TECK90 600V RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Industrial Lighting Circuits: Supplying 120V or 277V single-phase industrial plant lighting fixtures, high-bay luminaires, and perimeter floodlights.

  • Control & Interlock Loops: 2-wire discrete control runs between pushbuttons, limit switches, solenoids, and PLC input cards.

  • Chemical & Processing Plants: Single-phase power and control circuits routed through corrosive process areas, compressor sheds, and pump galleries.

  • Direct Burial & Trench Runs: Installing power runs directly underground between buildings, outbuildings, outdoor gate operators, and perimeter bollards without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.


See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.67 in. / 17.02 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 25
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.195 lb

Real World Applications

Real World Applications

  • Plant Lighting Feeds: Connecting high-bay industrial lighting fixtures in pulp mills, steel plants, and mining crushers where ambient dust and physical vibration compromise unarmored cables.
  • Field Solenoid & Actuator Drops: Powering 120V AC or 24V DC discrete pneumatic solenoid valves, flow switches, and electric valve actuators in processing skids.
  • Outdoor Perimeter & Site Power: Direct-burial feeds running from main facility breaker panels to remote gate operators, outdoor light poles, and cathodic protection units.
  • Conveyor Interlock & Pull-Cord Switches: Wiring emergency stop pull cords and alignment switches along open-air bulk material handling conveyors.
  • Wastewater Wet Wells & Basins: Routing auxiliary 120V circuits in damp, hydrogen-sulfide-rich environments where standard metallic conduit quickly corrodes.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.67 in. / 17.02 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 25
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.195 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

TECK90 cable originated in the Teck mining district of Ontario, Canada, where engineers required an armored, waterproof cable capable of withstanding the punishing mechanical and wet subterranean conditions of deep gold mines. The "90" refers to its 90°C maximum continuous dry/wet operating temperature rating governed by its RW90 cross-linked polyethylene insulation.

It consists of two 14 AWG Class B stranded bare copper conductors insulated with thermoset RW90 XLPE (color-coded Black and White) and an uninsulated 14 AWG bare copper grounding conductor. These conductors are cabled together and bound inside a lead-free, flame-retardant inner PVC bedding jacket, wrapped in Aluminum Interlocked Armor (0.58" diameter), and protected by an abrasion-, chemical-, UV-, and water-resistant black outer PVC jacket (0.67" overall diameter) rated down to -40°C.

Yes. TECK90 is fully code-certified for direct earth burial. Its dual PVC jackets protect against moisture ingress and soil acids, while the internal Aluminum Interlocked Armor shields the conductors against rocks, soil compaction, and accidental impact from trenching tools.

Standard commercial MC cable typically lacks an inner PVC bedding jacket and often comes without an outer PVC jacket, leaving the raw metal armor exposed to moisture and corrosive soils. TECK90 features two distinct PVC jackets—one inside the armor and one over the armor—providing a water-tight, chemical-resistant barrier rated to -40°C that permits direct burial and high-pressure chemical washdowns.

Yes. The outer jacket is rated for installation down to -40°C (-40°F). This ensures the PVC sheath remains pliable during pulling, spooling, and bending in sub-zero winter conditions without jacket embrittlement or cracking.

Wire America cuts 14/2 TECK90 custom by the foot. Whether your project requires a 60-foot whip to a remote solenoid or several thousand feet for a facility-wide lighting upgrade, we provide exact job-ready lengths to eliminate reel scrap and surplus material costs.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us