12/2 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  12-2TECK90

SKU :  12-2TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Wire Size 12 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter 0.70 in. / 17.78 mm
Conductor Count 2
Voltage Rating 600V
Ampacity Rating 30
Weight per Foot 0.228 lb

Get Product Details

Get Product Details

A rugged, two-conductor armored power, lighting, and control cable engineered for industrial processing plants, chemical facilities, pulp and paper mills, steel mills, mining operations, power generating stations, and commercial complexes. Featuring two 12 AWG bare copper circuit conductors (color-coded Black and White) alongside an uninsulated 14 AWG bare copper grounding conductor, this cable is shielded by a continuous Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and wide temperature extremes from -40°C to +90°C, it provides outstanding crush defense, impact resistance, and complete environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running single-phase power, 20-amp lighting branch circuits, or discrete 2-wire control loops across high-impact mechanical zones, chemical washdowns, or sub-zero climates, long-term durability determines plant uptime. The 12/2 TECK90 Cable eliminates the substantial labor, expense, and bending constraints associated with rigid conduit pipe systems. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands physical impacts, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous physical protection and mechanical crush defense while retaining superior flexibility for routing around structural steel and machine bases.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC bedding jacket under the armor and an abrasion-resistant, -40°C outer PVC jacket that repels moisture ingress, chemical washdowns, and ultraviolet rays.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation retains dielectric integrity up to 90°C and eliminates conductor deformation or insulation flow during sudden overload conditions.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, ensuring flexible installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing or splitting.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame standards (70,000 BTU/hr), preventing vertical fire propagation along dense cable tray banks.

Technical Specifications

  • Conductor Size: 12 AWG

  • Number of Conductors: 2 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black, White

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.62 inches (15.75 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.70 inches (17.78 mm)

  • Approximate Net Weight: 228 lbs / kft (339 kg/km)

  • Ampacity: 30 Amps (Based on CE Code Part 1, Table 2 for raceway/cable)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 12/2C W/GND AIA TECK90 600V HL RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Industrial Lighting Branch Circuits: Supplying 120V or 277V single-phase industrial plant lighting fixtures, high-bay luminaires, and perimeter floodlights.

  • Single-Phase Power Drops: Supplying 120V convenience power, industrial utility outlets, and localized control power feeds.

  • Chemical & Processing Plants: Single-phase power and control circuits routed through corrosive process areas, compressor sheds, and pump galleries.

  • Direct Burial & Trench Runs: Installing power runs directly underground between facility outbuildings, exterior lighting arrays, and outdoor equipment without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 12 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.70 in. / 17.78 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 30
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.228 lb

Real World Applications

Real World Applications

  • Plant Lighting Feeds: Connecting high-bay industrial lighting fixtures in pulp mills, steel plants, and mining crushers where ambient dust and physical vibration compromise unarmored cables.
  • Field Solenoid & Actuator Drops: Powering 120V AC discrete pneumatic solenoid valves, flow switches, and electric valve actuators in processing skids.
  • Outdoor Perimeter & Site Power: Direct-burial feeds running from main facility breaker panels to remote gate operators, outdoor light poles, and security systems.
  • Conveyor Safety & Stop Switches: Wiring continuous emergency-stop pull-cords, trip switches, and belt misalignment interlocks along outdoor bulk-handling conveyor lines.
  • Wastewater Treatment Basins: Routing single-phase auxiliary circuits through damp galleries and wet wells where high moisture and corrosive fumes quickly pit metallic conduit.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

12/2 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  12-2TECK90

SKU :  12-2TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Contact us for price
Ships in 1-2 days

Parent SKU :  12-2TECK90

SKU :  12-2TECK90-250

$550/ea.
$1,093/ea.
$2,175/ea.
$5,408/ea.
$10,760/ea.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A rugged, two-conductor armored power, lighting, and control cable engineered for industrial processing plants, chemical facilities, pulp and paper mills, steel mills, mining operations, power generating stations, and commercial complexes. Featuring two 12 AWG bare copper circuit conductors (color-coded Black and White) alongside an uninsulated 14 AWG bare copper grounding conductor, this cable is shielded by a continuous Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and wide temperature extremes from -40°C to +90°C, it provides outstanding crush defense, impact resistance, and complete environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running single-phase power, 20-amp lighting branch circuits, or discrete 2-wire control loops across high-impact mechanical zones, chemical washdowns, or sub-zero climates, long-term durability determines plant uptime. The 12/2 TECK90 Cable eliminates the substantial labor, expense, and bending constraints associated with rigid conduit pipe systems. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands physical impacts, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous physical protection and mechanical crush defense while retaining superior flexibility for routing around structural steel and machine bases.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC bedding jacket under the armor and an abrasion-resistant, -40°C outer PVC jacket that repels moisture ingress, chemical washdowns, and ultraviolet rays.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation retains dielectric integrity up to 90°C and eliminates conductor deformation or insulation flow during sudden overload conditions.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, ensuring flexible installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing or splitting.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame standards (70,000 BTU/hr), preventing vertical fire propagation along dense cable tray banks.

Technical Specifications

  • Conductor Size: 12 AWG

  • Number of Conductors: 2 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black, White

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.62 inches (15.75 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.70 inches (17.78 mm)

  • Approximate Net Weight: 228 lbs / kft (339 kg/km)

  • Ampacity: 30 Amps (Based on CE Code Part 1, Table 2 for raceway/cable)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 12/2C W/GND AIA TECK90 600V HL RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Industrial Lighting Branch Circuits: Supplying 120V or 277V single-phase industrial plant lighting fixtures, high-bay luminaires, and perimeter floodlights.

  • Single-Phase Power Drops: Supplying 120V convenience power, industrial utility outlets, and localized control power feeds.

  • Chemical & Processing Plants: Single-phase power and control circuits routed through corrosive process areas, compressor sheds, and pump galleries.

  • Direct Burial & Trench Runs: Installing power runs directly underground between facility outbuildings, exterior lighting arrays, and outdoor equipment without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 12 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.70 in. / 17.78 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 30
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.228 lb

Real World Applications

Real World Applications

  • Plant Lighting Feeds: Connecting high-bay industrial lighting fixtures in pulp mills, steel plants, and mining crushers where ambient dust and physical vibration compromise unarmored cables.
  • Field Solenoid & Actuator Drops: Powering 120V AC discrete pneumatic solenoid valves, flow switches, and electric valve actuators in processing skids.
  • Outdoor Perimeter & Site Power: Direct-burial feeds running from main facility breaker panels to remote gate operators, outdoor light poles, and security systems.
  • Conveyor Safety & Stop Switches: Wiring continuous emergency-stop pull-cords, trip switches, and belt misalignment interlocks along outdoor bulk-handling conveyor lines.
  • Wastewater Treatment Basins: Routing single-phase auxiliary circuits through damp galleries and wet wells where high moisture and corrosive fumes quickly pit metallic conduit.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 12 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.70 in. / 17.78 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 2
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 30
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.228 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

TECK90 cable originated in the Teck mining district of Ontario, Canada, where engineers required an armored, waterproof cable capable of withstanding the punishing mechanical and wet subterranean conditions of deep gold mines. The "90" refers to its 90°C maximum continuous dry/wet operating temperature rating governed by its RW90 cross-linked polyethylene insulation.

It consists of two 12 AWG Class B stranded bare copper conductors insulated with thermoset RW90 XLPE (color-coded Black and White) alongside an uninsulated 14 AWG bare copper grounding conductor. These conductors are cabled together and enclosed inside a lead-free, flame-retardant inner PVC bedding jacket, wrapped in Aluminum Interlocked Armor (0.62" diameter), and encased in an abrasion-, chemical-, UV-, and water-resistant black outer PVC jacket (0.70" overall diameter) rated down to -40°C.

A 12/2 configuration is typically selected for 20A branch circuits, 120V convenience power, single-phase 277V high-bay lighting networks, solenoid valves, unit heaters, and discrete 2-wire machinery safety interlocks across heavy commercial and industrial facilities.

Yes. TECK90 is fully code-certified for direct earth burial. Its dual PVC jackets protect against moisture ingress and soil acids, while the internal Aluminum Interlocked Armor shields the conductors against rocks, soil compaction, and accidental impact from trenching tools.

Standard commercial MC cable typically lacks an inner PVC bedding jacket and often comes without an outer PVC jacket, leaving the bare metal armor exposed to moisture, salts, and corrosive soils. TECK90 features two distinct PVC jackets—one inside the armor and one over the armor—providing a water-tight, chemical-resistant barrier rated down to -40°C that permits direct burial, tray runs, and high-pressure chemical washdowns.

Yes. The outer jacket is rated for installation down to -40°C (-40°F). This ensures the PVC jacket remains pliable during unspooling, pulling, and bending in sub-zero winter conditions without jacket embrittlement or cracking.

Wire America supplies TECK90 by the foot and in standard spools. Whether your project requires an 85-foot run to an automated packaging unit or several thousand feet for an entire plant-wide tray network, we ship exact job-ready lengths to eliminate reel scrap and surplus material costs.

Call Us. Icon

Call Us.

(833) 268-8644