600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
Wire Size 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 1.81 in. / 45.974 mm
Conductor Count 4
Voltage Rating 600
Ampacity Rating 320

Get Product Details

Get Product Details

"The industry standard for high-capacity secondary power distribution. Rated for 600V and designed for both direct burial and conduit applications, the Rust Quadruplex features rugged XLP insulation for superior moisture resistance and long-term durability in the most demanding underground environments."

Why Engineers Choose Rust 250-250-250-3/0 Aluminum URD Cable

The Rust 250 MCM Quadruplex is engineered for large-scale power distribution where high ampacity and cost-efficiency are critical. This 250 MCM Aluminum cable utilizes high-conductivity 1350-H19 aluminum. Its XLPE (Cross-Linked Polyethylene) insulation provides a massive advantage over standard PVC, offering superior resistance to heat, chemicals, and mechanical stress, ensuring your infrastructure remains stable for decades.

  • High-Ampacity Power: Designed for major secondary distribution where smaller gauges would suffer from excessive voltage drop or overheating.

  • Sunlight-Resistant XLPE: Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points.

  • Easy-Identify Neutral: For faster installation and safer maintenance, the 3/0 AWG neutral conductor features three extruded yellow stripes.

  • Direct Burial Ready: Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit systems.

Technical Specifications: 250 MCM Aluminum URD

ENGINEERING OVERVIEW: 250 250 250 3/0 Quadruplex URD 

  • Application: Secondary distribution circuits, underground service entrances, and high-amp sub-panels.

  • Voltage Rating: 600 Volts.

  • UL Listing: UL 854 (Service-Entrance Cable).

  • Conductor Material: Concentric stranded 1350-H19 series aluminum.

  • Phase Insulation: Black sunlight-resistant XLP (Cross-Linked Polyethylene).

  • Neutral Insulation: Black XLP with 3 extruded yellow stripes for easy identification.

  • Temperature Rating: 90°C (Wet or Dry).

  • Phase Conductor Size: 250 MCM (kcmil).

  • Neutral Conductor Size: 3/0 AWG (Reduced Neutral).

  • Outside Diameter (OD): 1.81 inches (45.974 mm)

  • Ampacity (Direct Burial): 320 Amps.

  • Ampacity (In Duct/Conduit): 250 Amps.

  • Weight: 1.215 lbs/ft

  • Compliance Standards: UL 854; Type USE-2; ASTM B-231, B-609, B-901.

Common Rust 250 MCM URD Applications

  • Multi-Family Residential Main Feeders: The primary choice for running underground power from a utility transformer to the main distribution centers of apartment complexes and condominium buildings.

  • Commercial Building Service Entrances: Ideal for medium-to-large retail centers, office buildings, and restaurants.

  • Industrial Sub-Panels: Frequently used as a feeder to provide secondary power to heavy machinery clusters, large air compressor banks, or specialized manufacturing zones within an industrial plant.

  • Large Agricultural Distribution: The standard for high-capacity farm infrastructure, such as powering large grain dryers, irrigation pumping stations, and climate-controlled livestock facilities.

  • Data Centers & Server Rooms: Reliable for secondary power distribution in tech facilities where high-load, continuous operation is the baseline.

  • Community Infrastructure: Perfect for powering shared amenities like community clubhouses, large public pool facilities, and sports field lighting complexes.



Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

 

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 1.81 in. / 45.974 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 320
Direct Burial Rating Yes
Submersible No
Flexibility Rating Low
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 1.215 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum Quadruplex Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Dyke 2 Gauge, 4 Conductor Quadruplex URD, Aluminum Direct Burial Cable.

250-250-250-3/0 Quadruplex Aluminum Direct Burial Cable, Rust URD

Parent SKU :  RST-4URD

SKU :  RST-4URD-100

600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
In Stock
Ships in 1-2 days

Parent SKU :  RST-4URD

SKU :  RST-4URD-100

$649/ea.
$1,599/ea.
$3,181/ea.
$6,328/ea.
$6.49/ft.
Please select an option
Min: 100 ft., Max: 20,000 ft.
Spool (100 ft.)
$649.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

"The industry standard for high-capacity secondary power distribution. Rated for 600V and designed for both direct burial and conduit applications, the Rust Quadruplex features rugged XLP insulation for superior moisture resistance and long-term durability in the most demanding underground environments."

Why Engineers Choose Rust 250-250-250-3/0 Aluminum URD Cable

The Rust 250 MCM Quadruplex is engineered for large-scale power distribution where high ampacity and cost-efficiency are critical. This 250 MCM Aluminum cable utilizes high-conductivity 1350-H19 aluminum. Its XLPE (Cross-Linked Polyethylene) insulation provides a massive advantage over standard PVC, offering superior resistance to heat, chemicals, and mechanical stress, ensuring your infrastructure remains stable for decades.

  • High-Ampacity Power: Designed for major secondary distribution where smaller gauges would suffer from excessive voltage drop or overheating.

  • Sunlight-Resistant XLPE: Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points.

  • Easy-Identify Neutral: For faster installation and safer maintenance, the 3/0 AWG neutral conductor features three extruded yellow stripes.

  • Direct Burial Ready: Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit systems.

Technical Specifications: 250 MCM Aluminum URD

ENGINEERING OVERVIEW: 250 250 250 3/0 Quadruplex URD 

  • Application: Secondary distribution circuits, underground service entrances, and high-amp sub-panels.

  • Voltage Rating: 600 Volts.

  • UL Listing: UL 854 (Service-Entrance Cable).

  • Conductor Material: Concentric stranded 1350-H19 series aluminum.

  • Phase Insulation: Black sunlight-resistant XLP (Cross-Linked Polyethylene).

  • Neutral Insulation: Black XLP with 3 extruded yellow stripes for easy identification.

  • Temperature Rating: 90°C (Wet or Dry).

  • Phase Conductor Size: 250 MCM (kcmil).

  • Neutral Conductor Size: 3/0 AWG (Reduced Neutral).

  • Outside Diameter (OD): 1.81 inches (45.974 mm)

  • Ampacity (Direct Burial): 320 Amps.

  • Ampacity (In Duct/Conduit): 250 Amps.

  • Weight: 1.215 lbs/ft

  • Compliance Standards: UL 854; Type USE-2; ASTM B-231, B-609, B-901.

Common Rust 250 MCM URD Applications

  • Multi-Family Residential Main Feeders: The primary choice for running underground power from a utility transformer to the main distribution centers of apartment complexes and condominium buildings.

  • Commercial Building Service Entrances: Ideal for medium-to-large retail centers, office buildings, and restaurants.

  • Industrial Sub-Panels: Frequently used as a feeder to provide secondary power to heavy machinery clusters, large air compressor banks, or specialized manufacturing zones within an industrial plant.

  • Large Agricultural Distribution: The standard for high-capacity farm infrastructure, such as powering large grain dryers, irrigation pumping stations, and climate-controlled livestock facilities.

  • Data Centers & Server Rooms: Reliable for secondary power distribution in tech facilities where high-load, continuous operation is the baseline.

  • Community Infrastructure: Perfect for powering shared amenities like community clubhouses, large public pool facilities, and sports field lighting complexes.



Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

 

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 1.81 in. / 45.974 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 320
Direct Burial Rating Yes
Submersible No
Flexibility Rating Low
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 1.215 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum Quadruplex Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Dyke 2 Gauge, 4 Conductor Quadruplex URD, Aluminum Direct Burial Cable.

Physical Specifications

Wire Size (AWG/MCM) 250 MCM
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 19
Outer Diameter (OD) (in/mm) 1.81 in. / 45.974 mm
Jacket Type XLPE
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 320
Direct Burial Rating Yes
Submersible No
Flexibility Rating Low
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
ASTM B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
ICEA S-105-692 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables
Federal Specification A-A-59544A
UL 854 Service-Entrance Cables
Sunlight Resistant
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction. *Not RUS accepted size **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.

Usage & Installation:

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 1.215 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us
  • Direct Burial: Approximately 320 Amps
  • In Duct/Conduit: Approximately 250 Amps

Note: These ratings are based on 90°C conductor temperature and standard ambient conditions. Always consult with a licensed electrical engineer and reference NEC Article 310.15 for project-specific calculations.

URD stands for Underground Residential Distribution. It is a category of electrical cable specifically engineered for direct burial in the earth. Unlike standard indoor wire, URD is built with rugged XLPE (Cross-Linked Polyethylene) insulation that is chemically designed to resist moisture, soil acids, and mechanical pressure without needing a protective outer jacket or conduit.

Yes. 250 MCM Quadruplex is a Type USE-2 cable specifically designed for direct burial. The XLPE insulation is formulated to resist moisture, soil chemicals, and mechanical stress, though conduit is often preferred at this size for added physical protection and ease of future maintenance.

Yes. While designed for underground use, the insulation is UV-rated. This is vital for the portions of the cable that emerge from the ground to enter a meter socket or transformer cabinet.

Absolutely. 250 MCM URD is the industry standard for secondary feeders in apartment complexes and large residential developments. It provides the necessary amperage to feed multiple meter banks from a central utility transformer.

By using a 3/0 neutral instead of a full 250 MCM neutral, the cable becomes slightly smaller, lighter, and more cost-effective. This is ideal for 3-phase systems where the load is relatively balanced, as the neutral only carries the unbalanced portion of the current.

Aluminum URD is the industry standard for underground utility feeds because it is significantly more cost-effective and lighter than copper. At the 250 MCM size, aluminum provides the necessary ampacity for large residential and commercial feeds at a fraction of the cost of copper.

With a nominal OD of 1.81 inches, this cable requires significant space for a safe pull:

  • Minimum Requirement: A 3-inch conduit is generally the code minimum for 40% fill.
  • Recommended: We strongly suggest a 3.5-inch or 4-inch conduit.
    At 250 MCM, the cable is extremely heavy and stiff. Using a larger conduit (4-inch) is common practice to minimize pulling tension and prevent insulation damage around bends. Always refer to a conduit fill chart and consult a licensed installer.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us