2 Gauge Aluminum Direct Burial Wire, Clemson URD

Parent SKU :  CLE-URD

SKU :  CLE-URD-250

600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
Wire Size 2 AWG
Conductor Material Stranded Aluminum
Strand Count 7
Outer Diameter 0.418 in. / 10.617 mm
Conductor Count 1
Voltage Rating 600V
Ampacity Rating 155

Product Details

Product Details

"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds."

Why Choose 2 AWG Aluminum URD?

This cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.

  • 600V Power Rating: Consistent performance in wet or dry locations up to 90°C.

  • Direct Burial Rated: Specifically designed to be buried directly in the earth without protective conduit.

  • Sunlight Resistant: XLP insulation prevents UV-driven degradation.

  • Versatile Installation: Optimized for direct-trench or conduit/duct applications.

Technical Specifications: 2 AWG URD

  • Conductor Size: 2 AWG 

  • Voltage: 600V

  • Insulation: Black Sunlight-Resistant XLP

  • Max Temp: 90°C (Wet/Dry)

  • Overall Diameter: 0.418 inches

  • Ampacity (Direct Burial): 155 Amps

  • Ampacity (In Duct): 115 Amps

  • Standards: UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted

Common Applications

  • Secondary Underground Distribution: Power feed from transformer to service entrance.

  • Residential & Farm Power: Reliable sub-panel feeds and outbuilding power.

  • Underground Routing: Ideal for direct-trenching or pull-through conduit.

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.


Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Stranded Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.418 in. / 10.617 mm
Jacket Type XLPE
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
Insulation Thickness 0.06 in.

Technical Specifications

Voltage Rating 600V
Ampacity Rating 155
Direct Burial Rating Yes
Submersible No
Flexibility Rating Good
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, 231
ASTM B901
UL 854
ICEA S-105-692
RUS ACCEPTED
Miscellaneous Information All values are nominal and subject to correction. Ampacity: 90ºC conductor temperature, 20ºC ambient temperature, RHO 90, 100% load factor. Neutral carries unbalanced load only.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.093 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum Single Conductor Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Princeton 6 Gauge Aluminum Single Conductor URD Direct Burial Cable.

2 Gauge Aluminum Direct Burial Wire, Clemson URD

Parent SKU :  CLE-URD

SKU :  CLE-URD-250

600 VOLT XLPE JACKET, SUNLIGHT RESISTANT. URD.
In Stock
Ships in 1-2 days

Parent SKU :  CLE-URD

SKU :  CLE-URD-250

$168/ea.
$334/ea.
$663/ea.
$0.68/ft.
Please select an option
Min: 250 ft., Max: 10,000 ft.
Spool (250 ft.)
$168.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds."

Why Choose 2 AWG Aluminum URD?

This cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.

  • 600V Power Rating: Consistent performance in wet or dry locations up to 90°C.

  • Direct Burial Rated: Specifically designed to be buried directly in the earth without protective conduit.

  • Sunlight Resistant: XLP insulation prevents UV-driven degradation.

  • Versatile Installation: Optimized for direct-trench or conduit/duct applications.

Technical Specifications: 2 AWG URD

  • Conductor Size: 2 AWG 

  • Voltage: 600V

  • Insulation: Black Sunlight-Resistant XLP

  • Max Temp: 90°C (Wet/Dry)

  • Overall Diameter: 0.418 inches

  • Ampacity (Direct Burial): 155 Amps

  • Ampacity (In Duct): 115 Amps

  • Standards: UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted

Common Applications

  • Secondary Underground Distribution: Power feed from transformer to service entrance.

  • Residential & Farm Power: Reliable sub-panel feeds and outbuilding power.

  • Underground Routing: Ideal for direct-trenching or pull-through conduit.

 


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.


Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Stranded Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.418 in. / 10.617 mm
Jacket Type XLPE
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
Insulation Thickness 0.06 in.

Technical Specifications

Voltage Rating 600V
Ampacity Rating 155
Direct Burial Rating Yes
Submersible No
Flexibility Rating Good
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, 231
ASTM B901
UL 854
ICEA S-105-692
RUS ACCEPTED
Miscellaneous Information All values are nominal and subject to correction. Ampacity: 90ºC conductor temperature, 20ºC ambient temperature, RHO 90, 100% load factor. Neutral carries unbalanced load only.

Usage & Installation

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.093 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum Single Conductor Direct Burial URD

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the Princeton 6 Gauge Aluminum Single Conductor URD Direct Burial Cable.

Physical Specifications

Wire Size (AWG/MCM) 2 AWG
Conductor Material Stranded Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.418 in. / 10.617 mm
Jacket Type XLPE
Conductor Count 1
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
Insulation Thickness 0.06 in.

Technical Specifications

Voltage Rating 600V
Ampacity Rating 155
Direct Burial Rating Yes
Submersible No
Flexibility Rating Good
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B230, 231
ASTM B901
UL 854
ICEA S-105-692
RUS ACCEPTED
Miscellaneous Information All values are nominal and subject to correction. Ampacity: 90ºC conductor temperature, 20ºC ambient temperature, RHO 90, 100% load factor. Neutral carries unbalanced load only.

Usage & Installation:

Primary ApplicationsUnderground Secondary Power Distribution
Common Uses
  • Single-family homes
  • Apartment complexes
  • Farms
  • Smaller commercial buildings.

Packaging & Dimensions:

Weight per Foot 0.093 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

The 2 AWG URD is a heavy-duty choice for secondary underground distribution from transformer to service entrance, powering high-demand residential or farm sub-panels, and as a flexible option for custom underground power routing in both direct-burial and conduit applications.

Single conductor URD is the best choice when your project requires independent conductor management, such as custom underground routing, specific phase-pulling in tight conduits, or replacing a single damaged lead in an existing distribution run.

Yes. The 2 AWG URD Aluminum Cable is designed for direct burial. The XLP insulation is specifically formulated to resist moisture and soil-based stressors without the need for additional protective conduit.

For 2 AWG URD Clemson, the ampacity is 155 Amps for direct burial and 115 Amps when installed in a duct or conduit. Always refer to NEC 310.15 or consult a licensed electrician to verify derating requirements for your specific installation environment.

No. This cable is strictly designed for underground utility distribution (direct burial or conduit). It does not meet the flame-retardant standards needed for residential branch circuits or interior wiring. Always use NEC-compliant interior wiring (like NM-B or MC cable) for interior runs.

We stock a full range of single conductor, duplex, triplex & quadruplex URD cables including 1 AWG URD, 1/0 URD, 2/0 URD, & 4/0 URD, You can browse our complete inventory and view detailed specifications for each size in our Full Aluminum URD Collection here.

URD Cable stands for Underground Residential Distribution. This cable is specifically engineered for direct burial, meaning you can place it in a trench without conduit (provided you follow local burial depth codes). It is rated for 600 Volts and is rugged enough to withstand the chemical and physical stresses of being surrounded by soil and moisture.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us