8/3 w/ Ground VNTC Tray Cable Type TC-ER (THHN PVC 600V)

Parent SKU :  TCTHN8-3

SKU :  TCTHN8-3-250

VNTC TYPE TC-ER. SUNIGHT RESISTANT & DIRECT BURIAL RATED.
Wire Size 8 AWG
Conductor Type Stranded
Outer Diameter 0.61 in.
Conductor Count 3
Voltage Rating 600V
Ampacity Rating 55
Direct Burial Yes

Get Product Details

Get Product Details

This heavy-duty 8 AWG 3-conductor Copper VNTC tray cable delivers reliable 600V power across industrial cable trays, commercial wireways, and direct-buried facility feeders. Engineered with Class B stranded bare copper phase conductors and dual-layer THHN/THWN-2 insulation, it includes a dedicated 10 AWG bare copper equipment ground wire in a compact, balanced assembly. Protected by a sunlight-, oil-, and moisture-resistant black Polyvinyl Chloride (PVC) outer jacket, it provides contractors with a versatile wiring solution rated for up to 50 Amps (75°C terminals) / 55 Amps (90°C rating) power distribution.

Built for Exposed Runs, Cable Trays & Trenching

Routing high-amperage machinery circuits or primary branch lines requires wiring that balances physical flexibility with extreme environmental defense. Type TC/TC-ER 8 AWG 3-conductor copper tray cable slashes field labor by eliminating the need to pull individual conductors through continuous metal conduit in industrial environments. It is fully code-approved for open-air ladder trays, underground duct banks, outdoor direct burial, and hazardous chemical or utility environments.

  • Exposed Run Certified (TC-ER): Approved for open-air runs between cable trays and machinery or equipment disconnects per NEC Article 336, cutting installation hardware and labor costs.

  • 3-Conductor Assembly with Ground: Features 3 black phase conductors marked with ICEA Method 4 identification ("1-One", "2-Two", "3-Three") alongside a dedicated 10 AWG bare copper ground wire.

  • THHN / THWN-2 Insulation: High-dielectric PVC with a tough nylon outer skin that protects against oils, chemicals, moisture, and pulling friction.

  • Rugged Environmental PVC Jacket: Thick black outer sheath forms a durable shield against UV sunlight exposure, direct burial earth pressures, and flame migration.

  • Hazardous Location Rated: Fully certified under IEEE 1202 / CSA FT4 vertical tray flame tests and approved for Class 1, Division 2 hazardous industrial locations.

Technical Specifications

  • Conductor Size: 8 AWG

  • Number of Conductors: 3 Conductors

  • Conductor Stranding: 7 Strands Class B Bare Copper

  • Ground Wire Size: 10 AWG Bare Copper

  • Conductor Material: Soft or Annealed Bare Copper (ASTM B3/B8)

  • Insulation Material: Polyvinylchloride (PVC) with Nylon Skin (THHN/THWN-2 per UL 83)

  • Insulation Thickness: 0.030" (0.76 mm)

  • Nylon Thickness: 0.005" (0.13 mm)

  • Jacket Material: Flame and sunlight-resistant Black PVC per UL 1277

  • Jacket Thickness: 0.060" (1.52 mm)

  • Nominal Overall Diameter: 0.61" (15.49 mm)

  • Net Weight: 303 lbs / kft

  • Ampacity: 40 Amps @ 60°C / 50 Amps @ 75°C / 55 Amps @ 90°C (NEC Table 310.16)

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C Wet or Dry Continuous Operating

  • Color Code: ICEA Method 4 (All Black Conductors with printed numbers "1-One", "2-Two", "3-Three" and Bare Ground)

  • Industry Designation: 8/3 W/G CU TC-ER THHN/PVC 600V Tray Cable

  • UL Listings & Code Approvals: UL Standard 1277 (Type TC / TC-ER), UL 83 (THHN/THWN-2), NEC Article 336, IEEE 1202/CSA FT4 70,000 BTU Flame Test, UL 1685 Vertical Tray Fire Test, Direct Burial, Sunlight Resistant, Class 1, Division 2 Hazardous Locations

Common Applications

  • Industrial Cable Trays & Raceways: Continuous power feeder and branch line routing across open ladder trays, wireways, and structural raceways.

  • 3-Phase Motor Power Supplies: Feeding uninterrupted power directly to industrial pump motors, commercial ventilation systems, and assembly line drives.

  • Direct Burial Commercial/Utility Trenching: Underground direct-buried feeders for commercial buildings, facility outbuildings, exterior lighting networks, and equipment pads.

  • Class 1, Division 2 Hazardous Environments: Compliant for harsh industrial chemical plants, refinery yards, and manufacturing facilities.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, NEC, and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 8 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.61 in.
Jacket Type PVC with a Nylon Jacket
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers Type TC/TC-ER, UL 83, UL 1277, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 83, UL1277
UL 1685 Vertical-Tray Fire-Propagation and Smoke-Release Test
Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
ICEA S-95-658
UL Listed as Type TC or TC-ER, Sunlight Resistant, Direct Burial
UL Listed to IEEE1202 and CSA FT4 70, 000 BTU Flame Test
ASTM B3, ASTM B8
NEC Article 336, Article 501, Article 725 for class 1 circuits
Miscellaneous Information All values are nominal and subject to correction *Ampacities for not more than three current-carrying conductors in raceway, cable, or earth (directly buried) at ambient temperature of 30°C per NEC table 310.16. Refer to the NEC for deratings due to different conditions.
Other Certifications UL 66, UL 83, UL1277, UL 1685

Usage & Installation

Primary ApplicationsIndustrial Power and Control Systems, Building Automation and Energy Management, Utility and Substation Wiring, Instrumentation and Process Control, Cable Tray Installations, Outdoor and Direct Burial.
Common Uses
  • Control circuits for motors
  • machinery
  • automated equipment
  • connecting sensors
  • actuators
  • and controllers for HVAC
  • lighting
  • and security systems.

Packaging & Dimensions:

Weight per Foot 0.303 lb

Real World Applications

Real World Applications

  • 3-Phase 3-Wire Industrial Feeder Lines: Supplying 208V, 480V, or 600V 3-phase power directly to distribution subpanels, disconnect switches, transformers, and motor control centers (MCCs) where a neutral conductor is not required.
  • Industrial Machinery Drops: Supplying continuous 50-amp power drops to complex automated machinery, industrial HVAC chillers, commercial processing equipment, and manufacturing drives directly from overhead cable trays.
  • Direct Burial Facility Subpanels: Direct-burying high-reliability 50A underground 3-wire power feeders to commercial utility structures, detached storage facilities, and outdoor equipment pads.
  • Refining & Chemical Processing Yards: Running multi-conductor power distribution through aggressive processing environments requiring gas, oil, chemical, UV, and flame protection.

Disclaimer: Application examples are for planning purposes only. Always verify exact load calculations, local AHJ regulations, and NEC guidelines with a licensed electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

THHN/PVC Tray Cable Flexibility

Wire America | Wire Flexibility Series

This video shows the construction, jacket, and flexibility of the 12 AWG-5C, 10 AWG-19C and 1/0-4C THHN/PVC 600V VNTC Tray Cables

8/3 w/ Ground VNTC Tray Cable Type TC-ER (THHN PVC 600V)

Parent SKU :  TCTHN8-3

SKU :  TCTHN8-3-250

VNTC TYPE TC-ER. SUNIGHT RESISTANT & DIRECT BURIAL RATED.
In Stock
Ships in 1-2 days

Parent SKU :  TCTHN8-3

SKU :  TCTHN8-3-250

$811/ea.
$1,613/ea.
$3,208/ea.
$7,979/ea.
$15,875/ea.
$3.29/ft.
Please select an option
Min: 250 ft., Max: 20,000 ft.
Spool (250 ft.)
$811.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

This heavy-duty 8 AWG 3-conductor Copper VNTC tray cable delivers reliable 600V power across industrial cable trays, commercial wireways, and direct-buried facility feeders. Engineered with Class B stranded bare copper phase conductors and dual-layer THHN/THWN-2 insulation, it includes a dedicated 10 AWG bare copper equipment ground wire in a compact, balanced assembly. Protected by a sunlight-, oil-, and moisture-resistant black Polyvinyl Chloride (PVC) outer jacket, it provides contractors with a versatile wiring solution rated for up to 50 Amps (75°C terminals) / 55 Amps (90°C rating) power distribution.

Built for Exposed Runs, Cable Trays & Trenching

Routing high-amperage machinery circuits or primary branch lines requires wiring that balances physical flexibility with extreme environmental defense. Type TC/TC-ER 8 AWG 3-conductor copper tray cable slashes field labor by eliminating the need to pull individual conductors through continuous metal conduit in industrial environments. It is fully code-approved for open-air ladder trays, underground duct banks, outdoor direct burial, and hazardous chemical or utility environments.

  • Exposed Run Certified (TC-ER): Approved for open-air runs between cable trays and machinery or equipment disconnects per NEC Article 336, cutting installation hardware and labor costs.

  • 3-Conductor Assembly with Ground: Features 3 black phase conductors marked with ICEA Method 4 identification ("1-One", "2-Two", "3-Three") alongside a dedicated 10 AWG bare copper ground wire.

  • THHN / THWN-2 Insulation: High-dielectric PVC with a tough nylon outer skin that protects against oils, chemicals, moisture, and pulling friction.

  • Rugged Environmental PVC Jacket: Thick black outer sheath forms a durable shield against UV sunlight exposure, direct burial earth pressures, and flame migration.

  • Hazardous Location Rated: Fully certified under IEEE 1202 / CSA FT4 vertical tray flame tests and approved for Class 1, Division 2 hazardous industrial locations.

Technical Specifications

  • Conductor Size: 8 AWG

  • Number of Conductors: 3 Conductors

  • Conductor Stranding: 7 Strands Class B Bare Copper

  • Ground Wire Size: 10 AWG Bare Copper

  • Conductor Material: Soft or Annealed Bare Copper (ASTM B3/B8)

  • Insulation Material: Polyvinylchloride (PVC) with Nylon Skin (THHN/THWN-2 per UL 83)

  • Insulation Thickness: 0.030" (0.76 mm)

  • Nylon Thickness: 0.005" (0.13 mm)

  • Jacket Material: Flame and sunlight-resistant Black PVC per UL 1277

  • Jacket Thickness: 0.060" (1.52 mm)

  • Nominal Overall Diameter: 0.61" (15.49 mm)

  • Net Weight: 303 lbs / kft

  • Ampacity: 40 Amps @ 60°C / 50 Amps @ 75°C / 55 Amps @ 90°C (NEC Table 310.16)

  • Voltage Rating: 600 Volts

  • Temperature Rating: 90°C Wet or Dry Continuous Operating

  • Color Code: ICEA Method 4 (All Black Conductors with printed numbers "1-One", "2-Two", "3-Three" and Bare Ground)

  • Industry Designation: 8/3 W/G CU TC-ER THHN/PVC 600V Tray Cable

  • UL Listings & Code Approvals: UL Standard 1277 (Type TC / TC-ER), UL 83 (THHN/THWN-2), NEC Article 336, IEEE 1202/CSA FT4 70,000 BTU Flame Test, UL 1685 Vertical Tray Fire Test, Direct Burial, Sunlight Resistant, Class 1, Division 2 Hazardous Locations

Common Applications

  • Industrial Cable Trays & Raceways: Continuous power feeder and branch line routing across open ladder trays, wireways, and structural raceways.

  • 3-Phase Motor Power Supplies: Feeding uninterrupted power directly to industrial pump motors, commercial ventilation systems, and assembly line drives.

  • Direct Burial Commercial/Utility Trenching: Underground direct-buried feeders for commercial buildings, facility outbuildings, exterior lighting networks, and equipment pads.

  • Class 1, Division 2 Hazardous Environments: Compliant for harsh industrial chemical plants, refinery yards, and manufacturing facilities.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, NEC, and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 8 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.61 in.
Jacket Type PVC with a Nylon Jacket
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers Type TC/TC-ER, UL 83, UL 1277, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 83, UL1277
UL 1685 Vertical-Tray Fire-Propagation and Smoke-Release Test
Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
ICEA S-95-658
UL Listed as Type TC or TC-ER, Sunlight Resistant, Direct Burial
UL Listed to IEEE1202 and CSA FT4 70, 000 BTU Flame Test
ASTM B3, ASTM B8
NEC Article 336, Article 501, Article 725 for class 1 circuits
Miscellaneous Information All values are nominal and subject to correction *Ampacities for not more than three current-carrying conductors in raceway, cable, or earth (directly buried) at ambient temperature of 30°C per NEC table 310.16. Refer to the NEC for deratings due to different conditions.
Other Certifications UL 66, UL 83, UL1277, UL 1685

Usage & Installation

Primary ApplicationsIndustrial Power and Control Systems, Building Automation and Energy Management, Utility and Substation Wiring, Instrumentation and Process Control, Cable Tray Installations, Outdoor and Direct Burial.
Common Uses
  • Control circuits for motors
  • machinery
  • automated equipment
  • connecting sensors
  • actuators
  • and controllers for HVAC
  • lighting
  • and security systems.

Packaging & Dimensions:

Weight per Foot 0.303 lb

Real World Applications

Real World Applications

  • 3-Phase 3-Wire Industrial Feeder Lines: Supplying 208V, 480V, or 600V 3-phase power directly to distribution subpanels, disconnect switches, transformers, and motor control centers (MCCs) where a neutral conductor is not required.
  • Industrial Machinery Drops: Supplying continuous 50-amp power drops to complex automated machinery, industrial HVAC chillers, commercial processing equipment, and manufacturing drives directly from overhead cable trays.
  • Direct Burial Facility Subpanels: Direct-burying high-reliability 50A underground 3-wire power feeders to commercial utility structures, detached storage facilities, and outdoor equipment pads.
  • Refining & Chemical Processing Yards: Running multi-conductor power distribution through aggressive processing environments requiring gas, oil, chemical, UV, and flame protection.

Disclaimer: Application examples are for planning purposes only. Always verify exact load calculations, local AHJ regulations, and NEC guidelines with a licensed electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
THHN/PVC Tray Cable Flexibility

Wire America | Wire Flexibility Series

This video shows the construction, jacket, and flexibility of the 12 AWG-5C, 10 AWG-19C and 1/0-4C THHN/PVC 600V VNTC Tray Cables

Physical Specifications

Wire Size (AWG/MCM) 8 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.61 in.
Jacket Type PVC with a Nylon Jacket
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers Type TC/TC-ER, UL 83, UL 1277, UL 1685

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 83, UL1277
UL 1685 Vertical-Tray Fire-Propagation and Smoke-Release Test
Approved for Class 1 or 2, Division 2 industrial hazardous locations per NEC
ICEA S-95-658
UL Listed as Type TC or TC-ER, Sunlight Resistant, Direct Burial
UL Listed to IEEE1202 and CSA FT4 70, 000 BTU Flame Test
ASTM B3, ASTM B8
NEC Article 336, Article 501, Article 725 for class 1 circuits
Miscellaneous Information All values are nominal and subject to correction *Ampacities for not more than three current-carrying conductors in raceway, cable, or earth (directly buried) at ambient temperature of 30°C per NEC table 310.16. Refer to the NEC for deratings due to different conditions.
Other Certifications UL 66, UL 83, UL1277, UL 1685

Usage & Installation:

Primary ApplicationsIndustrial Power and Control Systems, Building Automation and Energy Management, Utility and Substation Wiring, Instrumentation and Process Control, Cable Tray Installations, Outdoor and Direct Burial.
Common Uses
  • Control circuits for motors
  • machinery
  • automated equipment
  • connecting sensors
  • actuators
  • and controllers for HVAC
  • lighting
  • and security systems.

Packaging & Dimensions:

Weight per Foot 0.303 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

8 AWG 3-Conductor Copper Tray Cable (Type TC/TC-ER) is engineered for 40A to 50A primary power distribution, motor branch circuits, control networks, and direct-buried commercial or industrial facility feeders. It contains three 8 AWG insulated copper phase conductors and a 10 AWG bare copper equipment ground wire, making it ideal for 3-phase 3-wire power applications or single-phase 240V industrial loads without a neutral conductor.

TC-ER stands for Tray Cable - Exposed Run under UL 1277 standards. Under NEC Article 336, cables carrying this rating pass rigorous crush and impact tests, permitting them to be installed as exposed wiring outside of cable trays (between the tray and equipment disconnects) without requiring metal armor or continuous conduit.

Yes, absolutely. This cable is UL-listed for Direct Burial. Its heavy PVC outer jacket forms an impermeable barrier against soil pressure, groundwater, and earth corrosion without requiring a continuous conduit sleeve.

Yes. It is UL-approved for use in Class 1, Division 2 industrial hazardous locations per National Electrical Code guidelines. Its outer jacket passes the IEEE 1202 / CSA FT4 flame test and resists oils, UV sunlight, and harsh chemical exposure.

Yes, absolutely. The extruded black PVC outer jacket is explicitly UL-listed and sunlight-resistant per UL 1277 standards. It features built-in UV inhibitors that prevent jacket degradation, cracking, or color fading from long-term exposure to direct sunlight in open-air cable trays, rooftop runs, and outdoor facility raceways.

Wire America supplies commercial and industrial electrical contractors with premium tray cable directly from strategic regional distribution centers throughout the USA. When you order through us, you get:

  • Direct Technical & Order Support: Speak directly with wire and cable specialists to assist with project specs, tray fill sizing, ampacity ratings, and bulk order logistics.
  • Fast Job-Site Shipping: Strategic distribution dispatch delivers material directly to your shop, facility, or job site on schedule.
  • Cut-by-The-Foot Lengths: Order the exact footage needed for your job site to eliminate material waste, scrap, and extra reel handling costs.
  • Master Reels & Bulk Cuts Available: Full factory reels are in stock for large commercial installations, utility builds, and plant maintenance projects.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us