6/3 NM-B Copper Building Wire with Ground, 600V (Black Jacket)

Parent SKU :  NMB6-3

SKU :  NMB6-3-250

STRANDED COPPER • 600V • NON-METALLIC SHEATHED CABLE
Wire Size 6 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter 0.575 in.
Conductor Count 3
Voltage Rating 600V
Ampacity Rating 55
Weight per Foot 0.342 lb

Get Product Details

Get Product Details

A staple for modern residential electrical infrastructure, this 6 AWG NM-B Copper Building Wire is the professional’s choice for intermediate high-load circuits. Featuring two insulated current-carrying copper conductors and a dedicated bare ground, this cable provides a reliable, high-integrity power path for heavy household equipment while remaining flexible enough for easy routing through interior wood-frame construction.

Why Choose 6/3 NM-B Copper Building Wire?

This 2-conductor (plus ground) configuration is engineered specifically for indoor dry-location wiring. The Type NM-B classification allows for installation without conduit, saving significant labor time and material costs in residential settings. The use of premium annealed copper ensures low electrical resistance and minimal heat buildup, even during peak demand.

  • Optimized Copper Performance: Soft-drawn copper conductors deliver maximum conductivity and are easy to terminate in panel lugs and heavy-duty receptacles.

  • Simplified Installation Profile: The slick, black PVC outer jacket is designed to minimize drag when pulling through studs, joists, and tight attic spaces.

  • Integrated Safety Ground: Includes a full-sized bare copper grounding wire, ensuring a continuous low-impedance path for fault currents.

  • THHN-Grade Insulation: Each conductor is wrapped in heat-resistant PVC and finished with a clear nylon jacket, offering superior protection against nicks and abrasions during the pull.

Technical Specifications: 6/3 NM-B Copper

  • Conductor Size: 6 AWG

  • Number of Conductors: 2 (plus Ground)

  • Color Code: Black, White, Bare Ground

  • Ampacity: 55 Amps at 60°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Polyvinyl Chloride (PVC) with Nylon Covering (Type THHN)

  • Max Temp: 90°C (Dry locations only)

  • Conductor Material: Annealed (Soft) Copper

  • Standards: UL Standard 83, UL Standard 719, ASTM B-3, B-8, Federal Spec A-A-59544

Common Applications

  • Electric Clothes Dryers: The preferred gauge for high-efficiency residential drying units requiring dedicated 30A to 50A circuits.

  • Small HVAC Systems: Ideal for powering mini-split systems, medium-sized air conditioning units, and specialized air handling equipment.

  • Kitchen Range Branch Circuits: Frequently used for standard electric ovens and cooktops in modern kitchen remodels.

  • Hot Tub and Spa Feeders: Often utilized for the interior portion of the run feeding hot tub disconnects or small indoor sauna heaters.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. NM-B is for dry, indoor use only.

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) 60°C column for NM-B cable, regardless of the conductor temperature rating.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.575 in.
Jacket Type PVC
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.342 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

6/3 NM-B Copper Building Wire with Ground, 600V (Black Jacket)

Parent SKU :  NMB6-3

SKU :  NMB6-3-250

STRANDED COPPER • 600V • NON-METALLIC SHEATHED CABLE
In Stock
Ships in 1-2 days

Parent SKU :  NMB6-3

SKU :  NMB6-3-250

$1,375/ea.
$2,735/ea.
$5,441/ea.
$13,532/ea.
$5.58/ft.
Please select an option
Min: 250 ft., Max: 10,000 ft.
Spool (250 ft.)
$1,375.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A staple for modern residential electrical infrastructure, this 6 AWG NM-B Copper Building Wire is the professional’s choice for intermediate high-load circuits. Featuring two insulated current-carrying copper conductors and a dedicated bare ground, this cable provides a reliable, high-integrity power path for heavy household equipment while remaining flexible enough for easy routing through interior wood-frame construction.

Why Choose 6/3 NM-B Copper Building Wire?

This 2-conductor (plus ground) configuration is engineered specifically for indoor dry-location wiring. The Type NM-B classification allows for installation without conduit, saving significant labor time and material costs in residential settings. The use of premium annealed copper ensures low electrical resistance and minimal heat buildup, even during peak demand.

  • Optimized Copper Performance: Soft-drawn copper conductors deliver maximum conductivity and are easy to terminate in panel lugs and heavy-duty receptacles.

  • Simplified Installation Profile: The slick, black PVC outer jacket is designed to minimize drag when pulling through studs, joists, and tight attic spaces.

  • Integrated Safety Ground: Includes a full-sized bare copper grounding wire, ensuring a continuous low-impedance path for fault currents.

  • THHN-Grade Insulation: Each conductor is wrapped in heat-resistant PVC and finished with a clear nylon jacket, offering superior protection against nicks and abrasions during the pull.

Technical Specifications: 6/3 NM-B Copper

  • Conductor Size: 6 AWG

  • Number of Conductors: 2 (plus Ground)

  • Color Code: Black, White, Bare Ground

  • Ampacity: 55 Amps at 60°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Polyvinyl Chloride (PVC) with Nylon Covering (Type THHN)

  • Max Temp: 90°C (Dry locations only)

  • Conductor Material: Annealed (Soft) Copper

  • Standards: UL Standard 83, UL Standard 719, ASTM B-3, B-8, Federal Spec A-A-59544

Common Applications

  • Electric Clothes Dryers: The preferred gauge for high-efficiency residential drying units requiring dedicated 30A to 50A circuits.

  • Small HVAC Systems: Ideal for powering mini-split systems, medium-sized air conditioning units, and specialized air handling equipment.

  • Kitchen Range Branch Circuits: Frequently used for standard electric ovens and cooktops in modern kitchen remodels.

  • Hot Tub and Spa Feeders: Often utilized for the interior portion of the run feeding hot tub disconnects or small indoor sauna heaters.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. NM-B is for dry, indoor use only.

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) 60°C column for NM-B cable, regardless of the conductor temperature rating.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.575 in.
Jacket Type PVC
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.342 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.575 in.
Jacket Type PVC
Conductor Count 3
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.342 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

This 6 AWG, 3-conductor Non-Metallic Sheathed Cable is the industry standard for high-power residential branch circuits. It is most commonly used for heavy-duty appliances that require a 120/240V connection with a neutral and a ground. Typical applications include electric ranges, ovens, large hot tubs, and 50A to 60A sub-panels. It is also a popular choice for Level 2 EV Chargers that require a 50-amp circuit.

At the 6 AWG size, copper provides excellent conductivity and thermal stability, making it ideal for continuous high-load applications.

  • Integrated Ground: The cable contains three insulated conductors and one bare equipment grounding conductor, providing a complete and code-compliant path for fault current.
  • Cost-Effective Installation: NM-B (Non-Metallic) cable allows for rapid installation through bored holes in wood framing without the need for a separate conduit system, provided it is installed in a "dry" interior location.
  • Durable Construction: The conductors feature a PVC insulation with a thin nylon coating (often referred to as THHN/THWN-2 internals), which reduces friction during installation and increases resistance to abrasion.

Per NEC Article 334.80, NM-B cable must be sized using the 60°C temperature column of Table 310.16. While the internal conductors are rated for 90°C, the overall cable assembly is limited to the 60°C rating to account for heat dissipation within thermal insulation and wood framing.

  • 60°C Rating: 55 Amps
  • 75°C/90°C Rating (For Derating Only): 65A / 75A

⚠️ PRO TIP: Because 55 Amps is not a standard circuit breaker size, NEC 240.4(B) (the "Next Standard Size Up" rule) often allows this cable to be protected by a 60 Amp breaker, provided the actual load does not exceed 55 Amps.

This cable follows the standard color-coding used for 120/240V circuits in North America:

  1. Black: Hot (Line 1)
  2. Red: Hot (Line 2)
  3. White: Neutral
  4. Bare Copper: Ground

While 14, 12, and 10 AWG NM-B cables use color-coded jackets (White, Yellow, and Orange respectively), heavy-gauge 6 AWG NM-B typically features a Black outer jacket. The jacket is a flame-retardant, heat-resistant PVC.

To maintain code compliance and safety, 6/3 NM-B has strict environmental requirements:

  • Dry Locations Only: NM-B is not rated for wet or damp locations. It must never be installed outdoors, even if it is inside a conduit, as moisture can accumulate and cause the cable to fail.
  • Physical Protection: If the cable is run in an area where it could be hit (such as an unfinished basement wall), it must be protected by a sleeve or conduit.
  • Bending Radius: You must maintain a bending radius of at least 5 times the cable's diameter to ensure the copper strands and insulation are not compromised by excessive stress.