6/2 NM-B Copper Building Wire with Ground, 600V (Black Jacket)

Parent SKU :  NMB6-2

SKU :  NMB6-2-250

STRANDED COPPER • 600V • NON-METALLIC SHEATHED CABLE
Wire Size 6 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter .350 x .710 in.
Conductor Count 2
Voltage Rating 600V
Ampacity Rating 55
Weight per Foot 0.271 lb

Product Details

Product Details

A versatile staple for residential power, this 6 AWG NM-B Copper Building Wire is specifically engineered for high-demand interior branch circuits. Featuring two high-conductivity copper conductors and a dedicated bare grounding wire, this assembly provides a reliable, high-performance solution for powering the essential heavy-duty appliances in modern homes.

Why Choose 6/2 NM-B Copper Building Wire?

This 2-conductor (with ground) cable is designed for ease of use in dry-location residential wiring. The Type NM-B construction allows for direct routing through wooden framing members without the added complexity of conduit, while the solid annealed copper ensures minimal voltage drop and superior electrical efficiency for sustained loads.

  • High-Purity Copper Conductors: Soft-drawn copper provides maximum electrical throughput and remains flexible for easier termination and routing.

  • Streamlined Pulling Geometry: The flat, low-friction PVC jacket is optimized to glide through bored studs and joists, significantly reducing physical strain during the rough-in phase.

  • Simplified Grounding Path: Includes a full-sized bare copper grounding conductor to ensure immediate fault protection and total code compliance.

  • Advanced Insulation Shielding: Individual conductors are protected with heat-resistant PVC and a smooth nylon outer layer (THHN/THWN-2) to resist nicks and abrasions.

Technical Specifications: 6/2 NM-B Copper

  • Conductor Size: 6 AWG

  • Number of Conductors: 2 (plus Ground)

  • Color Code: Black, White, Bare Ground

  • Ampacity: 55 Amps at 60°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Polyvinyl Chloride (PVC) with Nylon Covering (Type THHN)

  • Max Temp: 90°C (Dry locations only)

  • Conductor Material: Annealed (Soft) Copper

  • Standards: UL Standard 83, UL Standard 719, ASTM B-3, B-8, Federal Spec A-A-59544

Common Applications

  • Electric Water Heaters: The standard gauge for dedicated circuits supplying high-capacity residential water heating units.

  • Mini-Split HVAC Systems: Ideal for powering external condenser units and indoor air handlers requiring 50A circuits.

  • 240V Garage Circuits: Frequently used for heavy-duty power tools, compressors, and welders in home workshops.

  • Large Appliance Feeders: A reliable choice for dedicated circuits for high-wattage equipment where a separate neutral is not required.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. NM-B is for dry, indoor use only.

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) 60°C column for NM-B cable, regardless of the conductor temperature rating.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) .350 x .710 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.271 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

6/2 NM-B Copper Building Wire with Ground, 600V (Black Jacket)

Parent SKU :  NMB6-2

SKU :  NMB6-2-250

STRANDED COPPER • 600V • NON-METALLIC SHEATHED CABLE
In Stock
Ships in 1-2 days

Parent SKU :  NMB6-2

SKU :  NMB6-2-250

$946/ea.
$1,882/ea.
$3,744/ea.
$9,312/ea.
$3.84/ft.
Please select an option
Min: 250 ft., Max: 10,000 ft.
Spool (250 ft.)
$946.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

A versatile staple for residential power, this 6 AWG NM-B Copper Building Wire is specifically engineered for high-demand interior branch circuits. Featuring two high-conductivity copper conductors and a dedicated bare grounding wire, this assembly provides a reliable, high-performance solution for powering the essential heavy-duty appliances in modern homes.

Why Choose 6/2 NM-B Copper Building Wire?

This 2-conductor (with ground) cable is designed for ease of use in dry-location residential wiring. The Type NM-B construction allows for direct routing through wooden framing members without the added complexity of conduit, while the solid annealed copper ensures minimal voltage drop and superior electrical efficiency for sustained loads.

  • High-Purity Copper Conductors: Soft-drawn copper provides maximum electrical throughput and remains flexible for easier termination and routing.

  • Streamlined Pulling Geometry: The flat, low-friction PVC jacket is optimized to glide through bored studs and joists, significantly reducing physical strain during the rough-in phase.

  • Simplified Grounding Path: Includes a full-sized bare copper grounding conductor to ensure immediate fault protection and total code compliance.

  • Advanced Insulation Shielding: Individual conductors are protected with heat-resistant PVC and a smooth nylon outer layer (THHN/THWN-2) to resist nicks and abrasions.

Technical Specifications: 6/2 NM-B Copper

  • Conductor Size: 6 AWG

  • Number of Conductors: 2 (plus Ground)

  • Color Code: Black, White, Bare Ground

  • Ampacity: 55 Amps at 60°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Polyvinyl Chloride (PVC) with Nylon Covering (Type THHN)

  • Max Temp: 90°C (Dry locations only)

  • Conductor Material: Annealed (Soft) Copper

  • Standards: UL Standard 83, UL Standard 719, ASTM B-3, B-8, Federal Spec A-A-59544

Common Applications

  • Electric Water Heaters: The standard gauge for dedicated circuits supplying high-capacity residential water heating units.

  • Mini-Split HVAC Systems: Ideal for powering external condenser units and indoor air handlers requiring 50A circuits.

  • 240V Garage Circuits: Frequently used for heavy-duty power tools, compressors, and welders in home workshops.

  • Large Appliance Feeders: A reliable choice for dedicated circuits for high-wattage equipment where a separate neutral is not required.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. NM-B is for dry, indoor use only.

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) 60°C column for NM-B cable, regardless of the conductor temperature rating.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) .350 x .710 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.271 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 6 AWG
Conductor Material Copper
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) .350 x .710 in.
Jacket Type PVC
Conductor Count 2
Shield Unshielded
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL 83

Technical Specifications

Voltage Rating 600V
Ampacity Rating 55
Submersible No
Temperature Rating 90ºC
Standards US 719
UL 83
ASTM B3 and B8
Miscellaneous Information All values are nominal and subject to correction.
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsWiring outlets, switches, and lighting circuits in residential buildings.

Packaging & Dimensions:

Weight per Foot 0.271 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

This 6 AWG, 2-conductor Non-Metallic Sheathed Cable is a heavy-duty residential power cable designed for high-amperage 240V circuits that do not require a neutral wire. It is the industry standard for dedicated 240V loads such as electric water heaters, baseboard heaters, and certain central air conditioning units. It is also frequently utilized for Level 2 EV chargers that utilize a 2-wire plus ground configuration (such as a NEMA 6-50 plug or hardwired setup).

At the 6 AWG size, copper provides the thermal stability and low resistance required for continuous high-draw equipment.

  • Integrated Ground: The cable contains two insulated conductors and one bare equipment grounding conductor, ensuring a safe path for fault current.
  • Simplified Routing: As an NM-B cable (Non-Metallic), it can be run directly through bored holes in wood studs and joists without the need for conduit, significantly lowering material and labor costs compared to THHN-in-pipe installations.
  • 2-Conductor Efficiency: By omitting the neutral wire required in "3-conductor" versions, the cable has a smaller overall diameter and is more cost-effective for equipment that only requires two "hot" legs.

In accordance with NEC Article 334.80, all NM-B cables must be rated based on the 60°C temperature column of Table 310.16. While the internal copper conductors are insulated with 90°C rated material, the overall assembly is limited to the 60°C rating to account for the heat-retention properties of residential wall cavities.

  • 60°C Rating: 55 Amps
  • 75°C/90°C Rating (For Derating Only): 65A / 75A

⚠️ PRO TIP: Since 55 Amps is not a standard breaker size, NEC 240.4(B) often allows you to move to the "next standard size up," which is a 60 Amp breaker, provided the actual calculated load of the appliance does not exceed 55 Amps.

This cable is designed for 240V branch circuits and follows standard identification:

  1. Black: Hot (Line 1)
  2. White: Typically Hot (Line 2) — Note: In a 240V application, the white wire must be re-identified with black or red tape at both ends to indicate it is a "hot" conductor.
  3. Bare Copper: Ground

While 14, 12, and 10 AWG NM-B use color-coded jackets, heavy-duty 6 AWG NM-B typically uses a Black outer jacket. The jacket is a flame-retardant, moisture-resistant PVC designed for easy pulling through wood framing.

To ensure long-term safety and code compliance, follow these installation rules:

  • Dry Locations Only: NM-B is strictly for indoor, dry environments. It must never be used outdoors, even in conduit, as the paper wrapping inside the jacket can wick moisture and lead to cable failure.
  • Structural Protection: If the cable is exposed in a garage or basement where it might be subject to physical damage, it should be protected by a sleeve of EMT or PVC conduit.
  • Bending Radius: Do not bend the cable to a radius smaller than 5 times its diameter. Sharp bends can stress the copper strands and compromise the insulation's integrity.