350 MCM 4C Direct Burial Aluminum MC Cable with Bare Ground (PVC Jacketed)

Parent SKU :  MCA350-4JKT

SKU :  MCA350-4JKT-250

4 CONDUCTOR + GROUND • ALUMINUM INTERLOCKED ARMOR • PVC JACKET • 600V
Wire Size 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 2.35 in.
Conductor Count 4
Voltage Rating 600V
Ampacity Rating 280
Weight per Foot 2.391 lb

Get Product Details

Get Product Details

"Engineered for maximum power capacity and tough underground environments, 350 MCM 4-Conductor Direct Burial Aluminum MC Cable delivers complete feeder protection without the added labor or expense of installing underground conduit.

This heavy-duty cable features four 350 MCM compact-stranded aluminum conductors (three phase legs + one full-size neutral) and one 1/0 aluminum bare ground conductor, protected by an interlocked aluminum armor and covered in a rugged, moisture-proof, UV-resistant PVC outer jacket. Fully approved per NEC Article 330 for direct earth burial, wet locations, and cable tray applications, it is the ultimate cost-effective solution for 250A three-phase 4-wire commercial distribution, industrial subpanels, and utility power runs."

Key Features & Benefits: 350 MCM-4C Direct Burial Alum MC Cable + Ground

  • Direct Burial Approved (No Conduit Required): The extruded PVC outer jacket isolates the interlocked aluminum armor from moisture, soil chemicals, and ground rot, allowing you to lay cable directly into open trenches.

  • 4-Conductor Commercial Layout: Features three phase conductors and one dedicated full-sized neutral—ideal for 3-phase 4-wire systems  or applications requiring separate insulated neutrals.

  • Compact Stranded AA-8000 Aluminum: Built with lightweight AA-8000 series aluminum alloy that reduces overall cable diameter, making it easier to pull through tight bends without sacrificing ampacity.

  • Superior Mechanical Armor: The flexible interlocked aluminum armor shields internal wires from soil shifts, sharp rocks, crushed backfill, and physical impacts during installation.

  • Sunlight & Flame Resistant: Designed to handle direct exposure to sunlight, wet locations, and indoor/outdoor transitions seamlessly.

Technical Specifications: 350 MCM 4 Conductor Direct Burial Alum MC Cable

  • Conductor Size: 350 MCM (kcmil)

  • Number of Power Conductors: 4

  • Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy

  • Ground Wire Size: 1/0 Bare Aluminum

  • Phase Colors: Black, White, Red, Blue 

  • Insulation Type: XLPE / XHHW-2

  • Armor Type: AIA (Aluminum Interlocked Armor)

  • Protective Outer Jacket: PVC - Black (Sunlight & Moisture Resistant)

  • Voltage Rating: 600 Volts

  • Temperature Rating: -40°C to 90°C

  • Amp Rating (@ 75°C - NEC): 250 Amps

  • Amp Rating (@ 90°C - NEC): 280 Amps

  • Insulation Thickness: 0.065 inches

  • Jacket Thickness: 0.070 inches

  • Approximate Nominal Outer Diameter: 2.35 inches

  • Approximate Net Weight: 2,391 lbs per 1,000 ft

  • Minimum Bending Radius: 16.45 inches (Calculated as 7x Diameter Over Jacket)

  • Compliance Standards: UL 44, UL 1569 (Type MC), NEMA WC70 / ICEA S-95-658, IEEE 1202, ASTM B800 & B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22.

Common 350 MCM-4 Alum MC Cable PVC Jacket Applications

  • Primary Service Entrances: Feeding heavy underground main power from utility-side transformers or outdoor meter banks to 250A–300A main breaker panels requiring a full-capacity neutral.

  • Industrial Feeder Networks: Supplying 3-phase power to manufacturing equipment, high-horsepower industrial water pumps, and primary distribution switchboards.

  • Commercial Building Feeder Runs: Routing dedicated 4-wire lines for high-output commercial HVAC chillers, backup generator networks, and large institutional complexes.

  • Concrete Structural Encasement: Laying primary electrical circuits directly within poured concrete foundations, parking garages, and shipping docks.

Ordering & Fulfillment

  • Cut to Length: Sold by the foot or in master reels to match your exact trench footprint and minimize scrap.

  • Fast Processing: Ships directly from closest regional distribution hubs to guarantee minimal transit times and reduced freight costs.

  • Submittal Assistance: Need cut sheets or manufacturer technical data sheets for engineering approval? Call our sales team directly at 833-268-8644 for immediate jobsite support.



Technical Note: To prevent structural degradation from galvanic corrosion, installers must utilize dual-rated AL7CU or AL9CU mechanical compression lugs or mechanical split-bolts when joining this aluminum cable to copper busbars or breaker terminals. Penetrox or similar antioxidant joint compound must be thoroughly applied to all bare aluminum conductors before final structural torquing. While the PVC jacket isolates the interior armor against direct soil or chemical contact, minimum trench depth profiles must strictly comply with NEC Article 300.5 tables (typically requiring 24 inches of earth cover for direct-buried cables not under concrete paths, or 18 inches beneath standard structural landscapes).

DISCLAIMER: The technical information provided is for general reference only. Large-scale high-voltage feeder systems and underground distribution paths must strictly adhere to the National Electrical Code (NEC), local electrical building enforcement, and relevant safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing structural configurations or executing structural cuts.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 2.35 in.
Jacket Type PVC
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1569

Technical Specifications

Voltage Rating 600V
Ampacity Rating 280
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambient temperature of 30°C (86°F).

Usage & Installation

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 2.391 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

350 MCM 4C Direct Burial Aluminum MC Cable with Bare Ground (PVC Jacketed)

Parent SKU :  MCA350-4JKT

SKU :  MCA350-4JKT-250

4 CONDUCTOR + GROUND • ALUMINUM INTERLOCKED ARMOR • PVC JACKET • 600V
Contact us for price
Ships in 1-2 days

Parent SKU :  MCA350-4JKT

SKU :  MCA350-4JKT-250

$4,263/ea.
$8,482/ea.
$16,878/ea.
$17.31/ft.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

"Engineered for maximum power capacity and tough underground environments, 350 MCM 4-Conductor Direct Burial Aluminum MC Cable delivers complete feeder protection without the added labor or expense of installing underground conduit.

This heavy-duty cable features four 350 MCM compact-stranded aluminum conductors (three phase legs + one full-size neutral) and one 1/0 aluminum bare ground conductor, protected by an interlocked aluminum armor and covered in a rugged, moisture-proof, UV-resistant PVC outer jacket. Fully approved per NEC Article 330 for direct earth burial, wet locations, and cable tray applications, it is the ultimate cost-effective solution for 250A three-phase 4-wire commercial distribution, industrial subpanels, and utility power runs."

Key Features & Benefits: 350 MCM-4C Direct Burial Alum MC Cable + Ground

  • Direct Burial Approved (No Conduit Required): The extruded PVC outer jacket isolates the interlocked aluminum armor from moisture, soil chemicals, and ground rot, allowing you to lay cable directly into open trenches.

  • 4-Conductor Commercial Layout: Features three phase conductors and one dedicated full-sized neutral—ideal for 3-phase 4-wire systems  or applications requiring separate insulated neutrals.

  • Compact Stranded AA-8000 Aluminum: Built with lightweight AA-8000 series aluminum alloy that reduces overall cable diameter, making it easier to pull through tight bends without sacrificing ampacity.

  • Superior Mechanical Armor: The flexible interlocked aluminum armor shields internal wires from soil shifts, sharp rocks, crushed backfill, and physical impacts during installation.

  • Sunlight & Flame Resistant: Designed to handle direct exposure to sunlight, wet locations, and indoor/outdoor transitions seamlessly.

Technical Specifications: 350 MCM 4 Conductor Direct Burial Alum MC Cable

  • Conductor Size: 350 MCM (kcmil)

  • Number of Power Conductors: 4

  • Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy

  • Ground Wire Size: 1/0 Bare Aluminum

  • Phase Colors: Black, White, Red, Blue 

  • Insulation Type: XLPE / XHHW-2

  • Armor Type: AIA (Aluminum Interlocked Armor)

  • Protective Outer Jacket: PVC - Black (Sunlight & Moisture Resistant)

  • Voltage Rating: 600 Volts

  • Temperature Rating: -40°C to 90°C

  • Amp Rating (@ 75°C - NEC): 250 Amps

  • Amp Rating (@ 90°C - NEC): 280 Amps

  • Insulation Thickness: 0.065 inches

  • Jacket Thickness: 0.070 inches

  • Approximate Nominal Outer Diameter: 2.35 inches

  • Approximate Net Weight: 2,391 lbs per 1,000 ft

  • Minimum Bending Radius: 16.45 inches (Calculated as 7x Diameter Over Jacket)

  • Compliance Standards: UL 44, UL 1569 (Type MC), NEMA WC70 / ICEA S-95-658, IEEE 1202, ASTM B800 & B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22.

Common 350 MCM-4 Alum MC Cable PVC Jacket Applications

  • Primary Service Entrances: Feeding heavy underground main power from utility-side transformers or outdoor meter banks to 250A–300A main breaker panels requiring a full-capacity neutral.

  • Industrial Feeder Networks: Supplying 3-phase power to manufacturing equipment, high-horsepower industrial water pumps, and primary distribution switchboards.

  • Commercial Building Feeder Runs: Routing dedicated 4-wire lines for high-output commercial HVAC chillers, backup generator networks, and large institutional complexes.

  • Concrete Structural Encasement: Laying primary electrical circuits directly within poured concrete foundations, parking garages, and shipping docks.

Ordering & Fulfillment

  • Cut to Length: Sold by the foot or in master reels to match your exact trench footprint and minimize scrap.

  • Fast Processing: Ships directly from closest regional distribution hubs to guarantee minimal transit times and reduced freight costs.

  • Submittal Assistance: Need cut sheets or manufacturer technical data sheets for engineering approval? Call our sales team directly at 833-268-8644 for immediate jobsite support.



Technical Note: To prevent structural degradation from galvanic corrosion, installers must utilize dual-rated AL7CU or AL9CU mechanical compression lugs or mechanical split-bolts when joining this aluminum cable to copper busbars or breaker terminals. Penetrox or similar antioxidant joint compound must be thoroughly applied to all bare aluminum conductors before final structural torquing. While the PVC jacket isolates the interior armor against direct soil or chemical contact, minimum trench depth profiles must strictly comply with NEC Article 300.5 tables (typically requiring 24 inches of earth cover for direct-buried cables not under concrete paths, or 18 inches beneath standard structural landscapes).

DISCLAIMER: The technical information provided is for general reference only. Large-scale high-voltage feeder systems and underground distribution paths must strictly adhere to the National Electrical Code (NEC), local electrical building enforcement, and relevant safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing structural configurations or executing structural cuts.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 2.35 in.
Jacket Type PVC
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1569

Technical Specifications

Voltage Rating 600V
Ampacity Rating 280
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambient temperature of 30°C (86°F).

Usage & Installation

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 2.391 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 2.35 in.
Jacket Type PVC
Conductor Count 4
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene
UL Listing Numbers UL 44, UL 1569

Technical Specifications

Voltage Rating 600V
Ampacity Rating 280
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL 44, 83, 1569 for Type MC Cable for CT Use
NEMA WC-70/ICEA S-95-658
IEEEE 1202 70, 000 BTU/HR Vertical Tray Flame Test
ASTM B800 & B801
NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22 for environmental air-handling spaces.
Miscellaneous Information All values are nominal and subject to correction. **Ampacities are based on NEC Table 310.15(B)(16), and show the allowable Ampacities of three current carrying insulated conductors, in a raceway, cable, or earth based on ambient temperature of 30°C (86°F).

Usage & Installation:

Primary ApplicationsService entrance conductors, Feeders, Branch circuits, Power, lighting, control, and signal circuits
Common Uses
  • Branch
  • feeder and service power distribution in commercial
  • industrial
  • and multi-residential buildings
  • power
  • lighting
  • control and signal circuits.

Packaging & Dimensions:

Weight per Foot 2.391 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

This high-capacity, jacketed armor cable is optimized for permanent installations requiring exceptional ampacity and structural protection without the labor of running rigid pipe conduits. Common uses include:

  • Industrial 3-Phase Power Distribution: Delivering reliable main power directly to massive manufacturing equipment, heavy-duty industrial motors, and master distribution switchboards.
  • Primary Service Entrances: Connecting utility-side transformers or high-output outdoor meter banks to large commercial building panels.
  • Commercial & Infrastructure Feeder Routes: Routing dedicated lines for heavy HVAC chiller systems, data center back-up generators, and large institutional complexes.
  • Concrete and Structural Encasement: Laying primary electrical circuits directly within poured concrete foundations, loading docks, and multi-story parking garages.

The most searched question regarding this heavy-gauge cable collection is why a 4-conductor setup is required instead of a 3-conductor line. The answer comes down to 3-Phase Power with a Dedicated Neutral. A 350 MCM 4C cable gives you four insulated wires (typically Black, Red, Blue, and White) plus a bare ground. This allows you to run full 3-phase industrial power with a completely independent neutral leg, which is absolutely essential for safely handling unbalanced building loads and protecting sensitive electronics from stray harmonic currents.

Wire America ships all of our Direct Burial Aluminum MC Cable directly from our centralized fulfillment centers throughout the United States. We are able to cut to length, process, and ship your order within 1–2 business days and ship straight to your job site, commercial, or residential property. Most standard orders arrive at your doorstep within 2 to 4 business days, with expedited shipping options available at checkout.

Stepping up to a massive 350 MCM conductor requires an engineered metallurgy that prioritizes system longevity, safety, and field handling:

  • Substantial Cost Savings: Aluminum delivers equivalent high-power transmission at a fraction of the cost of copper, making large-scale infrastructure and subpanel runs highly economical.
  • Reduced Weight: Aluminum's low density drastically reduces the total weight of the assembly, making it far easier for crews to handle, drop into trenches, and guide through tight entry bends.
  • Advanced Alloy Pliability: The 8000 series alloy is specifically processed to resist work-hardening, allowing this thick cable to bend smoothly and hold its shape without stressing the inner conductor strands.

No, you should never hitch this cable to a vehicle to pull it. Heavy 350 MCM cables have a Maximum Pulling Tension limit. Vehicles exert uncontrollable force that can stretch the internal aluminum conductors, thin out the insulation, or snap the interlocking metal armor. Always pull the cable by hand, or use a specialized electrical cable tugger equipped with a safety slip-clutch or tension gauge to avoid hidden internal damage.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us