2/0 RG Flex List 2 Central Office Power Cable - 600V

Parent SKU :  RG2/0-L2

SKU :  RG2/0-L2-250-RD

EXCELLENT FLEXIBILITY. LOW SMOKE ZERO HALOGEN (LSZH) INSULATION. DESIGNED FOR TELCO POWER APPLICATIONS.
Wire Size 2/0
Conductor Material Tinned Copper
Strand Count 342
Outer Diameter 0.630 in. / 16.00 mm
Weight per Foot 0.516 lb

Product Details

Product Details

APPLICATION:
The RG Flex Family of telecommunications power products has been tested and certified by Telcordia and meets the functional performance requirements of GR-347 Issue 3, TPR.9212 and ATIS-0600017.2020. Telcordia affirms that L2, L3 and L4 power cables are suitable for use in all telecommunications facilities including central offices, remote terminal applications and outside plant remote cabinets that house electronics equipment.

CONDUCTORS:
Class I annealed stranded tinned copper

COLOR CODE:
Red, Blue, Gray, Green or Black

INSULATION:
Thermosetting LSZH, lead-free, silicone-free

SEPARATOR:
Mylar tape over conductor

Max DC Resistance @20C:
0.087 ohms/kft

Flame Test:
VW-1 and FT4



Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. AWG 18 and 16 comply with UL 66.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 342
Outer Diameter (OD) (in/mm) 0.630 in. / 16.00 mm
Conductor Count 1
Shield Unshielded
Insulation Type Thermosetting LSZH
UL Listing Numbers UL 44, UL 66, UL 758, UL 2731

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 105°C
Standards Telcordia GR-347-CORE Compliant
ATIS 0600017.2020 Compliant
TPR.9212 Compliant
UL 2731 Telecommunications Central Office Power Cable
UL Listed Standard 44: Thermoset Insulated Type RHH/RHW/ST1
UL Listed Standard 66: Thermoset Insulated Type RFHH-2
UL Listed: For Tray Cable Use (1/0 & Larger)
FT-4 Flame Test Compliant
VW-1 Flame Test Compliant
CSA AWM 1 B 105C
Zero Halogen
IEC 60754 and IEC 60332 Compliant
RoHS / Reach Compliant
Miscellaneous Information Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. AWG 18 and 16 comply with UL 66.
Industry Standards Met List 2
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsAccess Network Equipment, Edge Routing and Switching, Customer-Facing Services (Non-Core Criticality), Support and Monitoring Systems.
Common Uses
  • DSLAMs (Digital Subscriber Line Access Multiplexers)
  • Optical Line Terminals (OLTs)
  • Cell Site Baseband Units (BBUs)
  • Passive Optical Network (PON) Equipment
  • Edge Routers/Switches
  • Voice over IP (VoIP) Gateways
  • Local Network Monitoring Stations
  • Building Management Systems (BMS).

Packaging & Dimensions:

Weight per Foot 0.516 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

RG Flex Central Office Power Cable, L2

Wire America | Wire Featured Product Series

This video breaks down the technical specs of the Red 12 AWG RG Flex List 2. This cable is engineered for power distribution in central offices and high-density computing environments.

2/0 RG Flex List 2 Central Office Power Cable - 600V

Parent SKU :  RG2/0-L2

SKU :  RG2/0-L2-250-RD

EXCELLENT FLEXIBILITY. LOW SMOKE ZERO HALOGEN (LSZH) INSULATION. DESIGNED FOR TELCO POWER APPLICATIONS.
In Stock
Ships in 1-2 days

Parent SKU :  RG2/0-L2

SKU :  RG2/0-L2-250-RD

Please select
Please select an option
$2,148/ea.
$4,273/ea.
$8,502/ea.
$21,146/ea.
$42,074/ea.
$8.72/ft.
Please select an option
Min: 250 ft., Max: 10,000 ft.
Select Color
Spool (250 ft.)
$2,148.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Product Details

Product Details

APPLICATION:
The RG Flex Family of telecommunications power products has been tested and certified by Telcordia and meets the functional performance requirements of GR-347 Issue 3, TPR.9212 and ATIS-0600017.2020. Telcordia affirms that L2, L3 and L4 power cables are suitable for use in all telecommunications facilities including central offices, remote terminal applications and outside plant remote cabinets that house electronics equipment.

CONDUCTORS:
Class I annealed stranded tinned copper

COLOR CODE:
Red, Blue, Gray, Green or Black

INSULATION:
Thermosetting LSZH, lead-free, silicone-free

SEPARATOR:
Mylar tape over conductor

Max DC Resistance @20C:
0.087 ohms/kft

Flame Test:
VW-1 and FT4



Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. AWG 18 and 16 comply with UL 66.

Full Specifications

Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 342
Outer Diameter (OD) (in/mm) 0.630 in. / 16.00 mm
Conductor Count 1
Shield Unshielded
Insulation Type Thermosetting LSZH
UL Listing Numbers UL 44, UL 66, UL 758, UL 2731

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 105°C
Standards Telcordia GR-347-CORE Compliant
ATIS 0600017.2020 Compliant
TPR.9212 Compliant
UL 2731 Telecommunications Central Office Power Cable
UL Listed Standard 44: Thermoset Insulated Type RHH/RHW/ST1
UL Listed Standard 66: Thermoset Insulated Type RFHH-2
UL Listed: For Tray Cable Use (1/0 & Larger)
FT-4 Flame Test Compliant
VW-1 Flame Test Compliant
CSA AWM 1 B 105C
Zero Halogen
IEC 60754 and IEC 60332 Compliant
RoHS / Reach Compliant
Miscellaneous Information Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. AWG 18 and 16 comply with UL 66.
Industry Standards Met List 2
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsAccess Network Equipment, Edge Routing and Switching, Customer-Facing Services (Non-Core Criticality), Support and Monitoring Systems.
Common Uses
  • DSLAMs (Digital Subscriber Line Access Multiplexers)
  • Optical Line Terminals (OLTs)
  • Cell Site Baseband Units (BBUs)
  • Passive Optical Network (PON) Equipment
  • Edge Routers/Switches
  • Voice over IP (VoIP) Gateways
  • Local Network Monitoring Stations
  • Building Management Systems (BMS).

Packaging & Dimensions:

Weight per Foot 0.516 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
RG Flex Central Office Power Cable, L2

Wire America | Wire Featured Product Series

This video breaks down the technical specs of the Red 12 AWG RG Flex List 2. This cable is engineered for power distribution in central offices and high-density computing environments.

Physical Specifications

Wire Size (AWG/MCM) 2/0
Conductor Material Tinned Copper
Conductor Type Stranded
Strand Count 342
Outer Diameter (OD) (in/mm) 0.630 in. / 16.00 mm
Conductor Count 1
Shield Unshielded
Insulation Type Thermosetting LSZH
UL Listing Numbers UL 44, UL 66, UL 758, UL 2731

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 105°C
Standards Telcordia GR-347-CORE Compliant
ATIS 0600017.2020 Compliant
TPR.9212 Compliant
UL 2731 Telecommunications Central Office Power Cable
UL Listed Standard 44: Thermoset Insulated Type RHH/RHW/ST1
UL Listed Standard 66: Thermoset Insulated Type RFHH-2
UL Listed: For Tray Cable Use (1/0 & Larger)
FT-4 Flame Test Compliant
VW-1 Flame Test Compliant
CSA AWM 1 B 105C
Zero Halogen
IEC 60754 and IEC 60332 Compliant
RoHS / Reach Compliant
Miscellaneous Information Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. AWG 18 and 16 comply with UL 66.
Industry Standards Met List 2
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsAccess Network Equipment, Edge Routing and Switching, Customer-Facing Services (Non-Core Criticality), Support and Monitoring Systems.
Common Uses
  • DSLAMs (Digital Subscriber Line Access Multiplexers)
  • Optical Line Terminals (OLTs)
  • Cell Site Baseband Units (BBUs)
  • Passive Optical Network (PON) Equipment
  • Edge Routers/Switches
  • Voice over IP (VoIP) Gateways
  • Local Network Monitoring Stations
  • Building Management Systems (BMS).

Packaging & Dimensions:

Weight per Foot 0.516 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us
AWG, or American Wire Gauge, is the standard system used primarily in North America to measure the diameter of electrical conductors. This system is critical because a wire's size directly impacts its electrical resistance and how much current (ampacity) it can safely carry. A key principle is that the smaller the AWG number, the larger the wire's diameter; for instance, 12 AWG is thicker and can carry more current than 14 AWG. Sizes beyond 0 AWG are referred to as "aught" (e.g., 1/0, 2/0). Selecting the correct AWG is essential for safe electrical installations, preventing overheating, and minimizing voltage drop.
Voltage drop is the natural reduction in electrical potential that occurs as current travels through a circuit, from the power source to a device. This happens because all wires inherently have resistance, which converts some electrical energy into heat, leading to a loss of voltage. While minor voltage drop is normal, excessive amounts can cause problems like dimming lights, slow or overheating motors, and erratic electronic behavior. It can also lead to higher energy consumption and, in severe cases, create safety hazards due to overheating wires. Key factors influencing voltage drop include the wire's length and thickness (gauge), the amount of current flowing through it, and the quality of electrical connections.
In electrical wiring, amps (amperes) measure the rate of electrical current flow. Think of it as the volume of electricity moving through the wire at any given time. Crucially, every electrical wire has an ampacity rating, which is the maximum current it can safely carry continuously without overheating. Exceeding a wire's ampacity can lead to insulation damage and fire hazards, highlighting why proper wire sizing based on expected amperage is vital for safe electrical systems.
A wire's ampacity, or its safe current-carrying capacity, changes with temperature primarily because of two factors. First, the electrical resistance of copper and aluminum wires increases as they get hotter, causing them to generate more heat when current flows. Second, every wire's insulation has a maximum temperature limit; exceeding this can cause degradation and safety hazards. Therefore, in hotter environments, a wire must carry less current to avoid exceeding its insulation's temperature rating. This ensures the wire remains safe and functional, preventing overheating and potential failures.
We aim to provide authentic, precise images of each wire; however, with various product variations, it can be challenging. In such instances, we focus on showcasing the fundamental design. Always refer to the product specifications rather than relying solely on images.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us