16-4 Pair MC-HL Armored Cable, Individual & Overall Shield, PVC-Nylon/PVC, 600V

Parent SKU :  MCHL16-4P-SPOS

SKU :  MCHL16-4P-SPOS-250

CCW ALUMINUM ARMOR • CLASS I, DIV 1 RATED • DIRECT BURIAL
Wire Size 16 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter 0.91 in. / 23.11 mm
Conductor Count 8
Voltage Rating 600V
Weight per Foot 0.335 lb

Get Product Details

Get Product Details

A heavy-duty, dual-shielded 600V instrumentation and control cable engineered for reliable signal transmission in Class I, II, and III Division 1 and 2 hazardous locations. Manufactured with stranded soft-drawn annealed copper conductors and PVC/Nylon insulation, this 16-4 Pair Type MC-HL Armored Cable pairs individual aluminum/polyester pair shields with an overall cable shield, a continuously welded impervious corrugated aluminum armor sheath, and a black PVC outer jacket rated for sunlight, oil, and direct burial resistance—delivering maximum EMI/RFI noise rejection and mechanical protection without rigid conduit.

Engineered for Hazardous Location Instrumentation, Process Control & Cable Tray Systems

UL 2225 Listed and compliant with NEC Articles 501–505 for Class I, II, and III Division 1 and 2 hazardous locations, this Type MC-HL Class 1 instrumentation cable combines multi-layer shielding with gas- and vapor-tight corrugated aluminum armor.

  • 600V Hazardous Location Rated Performance: UL Listed as Type MC-HL for Class I, II, and III Division 1 and 2 hazardous locations, as well as indoors or outdoors in wet or dry environments, cable trays, and direct burial.

  • Individual & Overall Shielding (SP-OS) for Maximum Noise Immunity: Each of the four twisted pairs features an overlapping aluminum/polyester foil shield with a 7-strand tinned copper drain wire to eliminate pair-to-pair crosstalk, wrapped beneath an overall overlapping aluminum/polyester shield and an additional 7-strand tinned copper drain wire to block external electromagnetic interference.

  • Continuously Welded, Impervious Corrugated Aluminum Armor: Gas- and vapor-tight corrugated aluminum sheath provides crush resistance, flexibility during tray or conduit-free routing, and exceeds the equipment grounding requirements of NEC 250.122.

  • Dual PVC Jackets with Rip Cord: A 50-mil black PVC inner bedding jacket with an integrated rip cord simplifies stripping and armor termination, while a 50-mil black PVC outer jacket provides sunlight, oil, and direct burial resistance.

  • Code-Compliant Industrial Construction: Fully listed to UL 83, UL 1581, UL 1569, UL 2225, and compliant with NEC Articles 250-118, 501, 502, 503, 504, 505, and 725.

Technical Specifications: 16-4 Pair Type MC-HL Armored Cable 

  • Conductor Size: 16 AWG (4 Twisted Pairs / 8 Total Conductors)

  • Conductor Material: Stranded Soft-Drawn Annealed Bare Copper

  • Conductor Insulation: Polyvinyl Chloride (PVC), 15 mils, plus Nylon Jacket, 4 mils

  • Pair Color Code: Pairs 1–4: Black and White (numbered/identified per pair)

  • Shielding Construction: Individual & Overall Shield (SP-OS) — Overlapping aluminum/polyester foil shield with 7-strand tinned copper drain wire per pair, plus overall overlapping aluminum/polyester foil shield with 7-strand tinned copper drain wire

  • Core Assembly: Left-hand lay twisted pairs with non-wicking fillers for a round core finish (0.56" Nominal Core O.D.)

  • Inner Jacket: Black Polyvinyl Chloride (PVC), 50 mils thick, with rip cord for easy removal

  • Armor: Continuously Welded, Impervious, Corrugated Aluminum Armor (0.80" Armor O.D.) — Exceeds NEC 250.122 grounding requirements

  • Outer Jacket: Black Polyvinyl Chloride (PVC), 50 mils thick (rated for sunlight, oil, and direct burial resistance)

  • Nominal Outside Diameter (O.D.): 0.91 inches

  • Cross-Sectional Area: 0.65 sq. in.

  • Approximate Net Weight: 335 lbs / kft

  • Voltage Rating: 600 Volts

  • Environmental Ratings: Wet or Dry Locations, Sunlight Resistant, Direct Burial, Oil Resistant, UL Listed for Cable Tray Use

  • Industry Standards & Listings: UL Listed MC Cable, UL Listed Type MC-HL, UL 83, UL 1581, UL 1569, UL 2225; Meets NEC Articles 250-118, 501, 502, 503, 504, 505, and 725 

Common Applications

  • Hazardous Location Process Control & Instrumentation: Transmits 600V remote-control signaling and low-level analog/digital instrumentation signals above 100 millivolts in Class I, II, and III Division 1 and 2 environments.

  • Industrial Cable Tray & Exposed Plant Runs: Installs directly in ventilated, ladder, or solid-bottom cable trays without requiring rigid metal conduit.

  • Outdoor, Wet & Direct-Burial Runs: Routes continuously from indoor control rooms through outdoor pipe racks, wet process areas, or direct-burial trenches into field junction boxes.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances. Buyers must verify project specifications and local electrical code compliance prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 16 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.91 in. / 23.11 mm
Jacket Type (PVC) Polyvinyl Chloride
Conductor Count 8
Shield Coverage % 1
Shield Type Aluminum Polyester
Shield Individual and Overall Shield
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL83, UL1581, UL1569, UL2225

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL Listed MC Cable
UL Listed as Type MC-HL
UL Listed for cable tray use
UL83, UL1581, UL1569, UL2225
Meets NEC Articles 250-118, 501, 502, 503, 504, 505, and 725 for hazardous locations
Sunlight Resistant, Direct Burial, Oil Resistant

Usage & Installation

Primary ApplicationsPetrochemical or oil & gas processing plants, food processing, metals,mining, power generation, pulp & paper, transportation, and other industrial plant settings.

Packaging & Dimensions:

Weight per Foot 0.335 lb

Real World Applications

Real World Applications

  • Refineries, Petrochemical & Chemical Processing Plants: Consolidating four independent 4–20 mA transmitter or RTD loops from Class I Division 1/2 process units back to marshalling cabinets in a single armored run where individual pair shields prevent signal bleed between adjacent loops.
  • Oil & Gas Compression, Pipeline & Power Generation Facilities: Routing 0.91" O.D. multi-pair instrumentation cable across outdoor cable trays and hazardous skids exposed to oil, UV sunlight, and mechanical vibration.
  • Mining, Metals, Pulp & Paper, and Food Processing Plants: Deploying crush-resistant, impervious corrugated aluminum armored cable in harsh washdown, heavy industrial, and direct-burial plant corridors.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, hazardous area classifications, and local AHJ regulations with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

16-4 Pair MC-HL Armored Cable, Individual & Overall Shield, PVC-Nylon/PVC, 600V

Parent SKU :  MCHL16-4P-SPOS

SKU :  MCHL16-4P-SPOS-250

CCW ALUMINUM ARMOR • CLASS I, DIV 1 RATED • DIRECT BURIAL
Contact us for price
Ships in 1-2 days

Parent SKU :  MCHL16-4P-SPOS

SKU :  MCHL16-4P-SPOS-250

$1,929/ea.
$3,837/ea.
$7,635/ea.
$18,988/ea.
$37,780/ea.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A heavy-duty, dual-shielded 600V instrumentation and control cable engineered for reliable signal transmission in Class I, II, and III Division 1 and 2 hazardous locations. Manufactured with stranded soft-drawn annealed copper conductors and PVC/Nylon insulation, this 16-4 Pair Type MC-HL Armored Cable pairs individual aluminum/polyester pair shields with an overall cable shield, a continuously welded impervious corrugated aluminum armor sheath, and a black PVC outer jacket rated for sunlight, oil, and direct burial resistance—delivering maximum EMI/RFI noise rejection and mechanical protection without rigid conduit.

Engineered for Hazardous Location Instrumentation, Process Control & Cable Tray Systems

UL 2225 Listed and compliant with NEC Articles 501–505 for Class I, II, and III Division 1 and 2 hazardous locations, this Type MC-HL Class 1 instrumentation cable combines multi-layer shielding with gas- and vapor-tight corrugated aluminum armor.

  • 600V Hazardous Location Rated Performance: UL Listed as Type MC-HL for Class I, II, and III Division 1 and 2 hazardous locations, as well as indoors or outdoors in wet or dry environments, cable trays, and direct burial.

  • Individual & Overall Shielding (SP-OS) for Maximum Noise Immunity: Each of the four twisted pairs features an overlapping aluminum/polyester foil shield with a 7-strand tinned copper drain wire to eliminate pair-to-pair crosstalk, wrapped beneath an overall overlapping aluminum/polyester shield and an additional 7-strand tinned copper drain wire to block external electromagnetic interference.

  • Continuously Welded, Impervious Corrugated Aluminum Armor: Gas- and vapor-tight corrugated aluminum sheath provides crush resistance, flexibility during tray or conduit-free routing, and exceeds the equipment grounding requirements of NEC 250.122.

  • Dual PVC Jackets with Rip Cord: A 50-mil black PVC inner bedding jacket with an integrated rip cord simplifies stripping and armor termination, while a 50-mil black PVC outer jacket provides sunlight, oil, and direct burial resistance.

  • Code-Compliant Industrial Construction: Fully listed to UL 83, UL 1581, UL 1569, UL 2225, and compliant with NEC Articles 250-118, 501, 502, 503, 504, 505, and 725.

Technical Specifications: 16-4 Pair Type MC-HL Armored Cable 

  • Conductor Size: 16 AWG (4 Twisted Pairs / 8 Total Conductors)

  • Conductor Material: Stranded Soft-Drawn Annealed Bare Copper

  • Conductor Insulation: Polyvinyl Chloride (PVC), 15 mils, plus Nylon Jacket, 4 mils

  • Pair Color Code: Pairs 1–4: Black and White (numbered/identified per pair)

  • Shielding Construction: Individual & Overall Shield (SP-OS) — Overlapping aluminum/polyester foil shield with 7-strand tinned copper drain wire per pair, plus overall overlapping aluminum/polyester foil shield with 7-strand tinned copper drain wire

  • Core Assembly: Left-hand lay twisted pairs with non-wicking fillers for a round core finish (0.56" Nominal Core O.D.)

  • Inner Jacket: Black Polyvinyl Chloride (PVC), 50 mils thick, with rip cord for easy removal

  • Armor: Continuously Welded, Impervious, Corrugated Aluminum Armor (0.80" Armor O.D.) — Exceeds NEC 250.122 grounding requirements

  • Outer Jacket: Black Polyvinyl Chloride (PVC), 50 mils thick (rated for sunlight, oil, and direct burial resistance)

  • Nominal Outside Diameter (O.D.): 0.91 inches

  • Cross-Sectional Area: 0.65 sq. in.

  • Approximate Net Weight: 335 lbs / kft

  • Voltage Rating: 600 Volts

  • Environmental Ratings: Wet or Dry Locations, Sunlight Resistant, Direct Burial, Oil Resistant, UL Listed for Cable Tray Use

  • Industry Standards & Listings: UL Listed MC Cable, UL Listed Type MC-HL, UL 83, UL 1581, UL 1569, UL 2225; Meets NEC Articles 250-118, 501, 502, 503, 504, 505, and 725 

Common Applications

  • Hazardous Location Process Control & Instrumentation: Transmits 600V remote-control signaling and low-level analog/digital instrumentation signals above 100 millivolts in Class I, II, and III Division 1 and 2 environments.

  • Industrial Cable Tray & Exposed Plant Runs: Installs directly in ventilated, ladder, or solid-bottom cable trays without requiring rigid metal conduit.

  • Outdoor, Wet & Direct-Burial Runs: Routes continuously from indoor control rooms through outdoor pipe racks, wet process areas, or direct-burial trenches into field junction boxes.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances. Buyers must verify project specifications and local electrical code compliance prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 16 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.91 in. / 23.11 mm
Jacket Type (PVC) Polyvinyl Chloride
Conductor Count 8
Shield Coverage % 1
Shield Type Aluminum Polyester
Shield Individual and Overall Shield
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL83, UL1581, UL1569, UL2225

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL Listed MC Cable
UL Listed as Type MC-HL
UL Listed for cable tray use
UL83, UL1581, UL1569, UL2225
Meets NEC Articles 250-118, 501, 502, 503, 504, 505, and 725 for hazardous locations
Sunlight Resistant, Direct Burial, Oil Resistant

Usage & Installation

Primary ApplicationsPetrochemical or oil & gas processing plants, food processing, metals, mining, power generation, pulp & paper, transportation, and other industrial plant settings.

Packaging & Dimensions:

Weight per Foot 0.335 lb

Real World Applications

Real World Applications

  • Refineries, Petrochemical & Chemical Processing Plants: Consolidating four independent 4–20 mA transmitter or RTD loops from Class I Division 1/2 process units back to marshalling cabinets in a single armored run where individual pair shields prevent signal bleed between adjacent loops.
  • Oil & Gas Compression, Pipeline & Power Generation Facilities: Routing 0.91" O.D. multi-pair instrumentation cable across outdoor cable trays and hazardous skids exposed to oil, UV sunlight, and mechanical vibration.
  • Mining, Metals, Pulp & Paper, and Food Processing Plants: Deploying crush-resistant, impervious corrugated aluminum armored cable in harsh washdown, heavy industrial, and direct-burial plant corridors.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, hazardous area classifications, and local AHJ regulations with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 16 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.91 in. / 23.11 mm
Jacket Type (PVC) Polyvinyl Chloride
Conductor Count 8
Shield Coverage % 1
Shield Type Aluminum Polyester
Shield Individual and Overall Shield
Insulation Type (PVC) Polyvinyl Chloride
UL Listing Numbers UL83, UL1581, UL1569, UL2225

Technical Specifications

Voltage Rating 600V
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL Listed MC Cable
UL Listed as Type MC-HL
UL Listed for cable tray use
UL83, UL1581, UL1569, UL2225
Meets NEC Articles 250-118, 501, 502, 503, 504, 505, and 725 for hazardous locations
Sunlight Resistant, Direct Burial, Oil Resistant

Usage & Installation:

Primary ApplicationsPetrochemical or oil & gas processing plants, food processing, metals, mining, power generation, pulp & paper, transportation, and other industrial plant settings.

Packaging & Dimensions:

Weight per Foot 0.335 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

16-4 Pair Type MC-HL (Metal-Clad Hazardous Location) cable is a 600V dual-shielded multi-pair instrumentation and control cable built for Class I, II, and III Division 1 and 2 hazardous locations. Combining four 16 AWG PVC/Nylon insulated twisted pairs, individual and overall aluminum/polyester foil shields with tinned copper drain wires, and a continuously welded corrugated aluminum sheath, it delivers low-noise signal transmission for multi-loop process control, remote signaling, and instrumentation circuits operating above 100 millivolts.

SP-OS (Shielded Pairs with Overall Shield) provides two layers of electromagnetic and electrostatic interference protection. Each 16 AWG twisted pair is wrapped in its own aluminum/polyester foil shield with a dedicated 7-strand tinned copper drain wire to eliminate crosstalk between pairs, while an overall aluminum/polyester foil shield and an additional 7-strand tinned copper drain wire enclose the entire core to block external EMI/RFI noise from nearby motors, VFDs, and power feeders.

Unlike standard interlocked MC cable, Type MC-HL features a continuously welded, impervious corrugated aluminum sheath (often referred to as CCW armor) that forms a gas- and vapor-tight barrier. Under UL 2225 and NEC Articles 501–505, this impervious armor prevents hazardous gases, vapors, or combustible dusts from migrating through the cable core when terminated with listed MC-HL explosion-proof glands, and its low-impedance sheath exceeds the equipment grounding requirements of NEC 250.122.

Yes. This cable is UL Listed for cable tray use, sunlight resistant, oil resistant, and rated for wet or dry locations as well as direct burial. Its 50-mil black PVC outer jacket protects the corrugated aluminum armor against soil corrosion, moisture, UV exposure, and industrial oils in both above-ground tray systems and underground trenches.

This UL 2225, UL 1569, UL 1581, and UL 83 listed cable complies with NEC Article 250-118 (equipment grounding via the impervious aluminum sheath), Articles 501, 502, 503, 504, and 505 (Class I, II, III and Zone hazardous locations), and Article 725 (Class 1 remote-control and signaling circuits). Always confirm fitting selection (such as TMCX or Class I Div 1/2 MC-HL connectors) with your plant electrical engineer or local AHJ.

Wire America stocks Type MC-HL Cable and industrial instrumentation armored cables ready for rapid turnaround on capital projects, turnarounds, and MRO orders:

  • Custom Cut-to-Length Spools: Order the exact footage required for your instrument loop schedule or tray pull to eliminate costly armored cable scrap.
  • Fast Nationwide Shipping: Rapid dispatch from regional distribution hubs to keep plant shutdowns, refinery turnarounds, and industrial builds on schedule.
  • Expert Technical/Sales Support: Direct access to knowledgeable wire and cable specialists for instant quotes, UL 2225 / MC-HL submittal verification, and project takeoff requirements.
Call Us. Icon

Call Us.

(833) 268-8644

Email Us