14/6 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  14-6TECK90

SKU :  14-6TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Wire Size 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter 0.80 in. / 20.32 mm
Conductor Count 6
Voltage Rating 600V
Ampacity Rating 20
Weight per Foot 0.316 lb

Get Product Details

Get Product Details

A heavy-duty, multi-conductor armored control cable engineered for industrial processing facilities, chemical plants, pulp and paper mills, steel manufacturing, mines, power generating stations, and commercial installations. Featuring six 14 AWG bare copper circuit conductors (Black with printed numbers) alongside an uninsulated bare copper grounding conductor, this cable is protected by a flexible Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and extreme thermal spans from -40°C to +90°C, it delivers superior physical protection, crush resistance, and environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running multi-device control circuits, push-button stations, and interlock loops through corrosive atmospheres, physical abuse zones, or sub-zero northern climates, structural reliability ensures continuous plant uptime. The 14/6 TECK90 Cable eliminates the high material cost, rigid bending limitations, and pull-labor of traditional conduit-and-wire installations. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands heavy mechanical impact, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous mechanical shielding and impact protection while preserving cable flexibility for complex routing around structural steel and machine frames.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC jacket under the armor and a heavy-duty -40°C outer PVC jacket that defends against water ingress, chemical washdowns, sunlight (UV), and outer abrasion.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation maintains dielectric strength up to 90°C and eliminates conductor deformation or insulation flow during thermal spikes.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, allowing cold-weather installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame tests (70,000 BTU/hr), preventing vertical fire propagation along industrial tray runs.

Technical Specifications

  • Conductor Size: 14 AWG

  • Number of Conductors: 6 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black conductors with printed numbers (1 to 6)

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.72 inches (18.29 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.80 inches (20.32 mm)

  • Approximate Net Weight: 316 lbs / kft (470 kg/km)

  • Ampacity: 20 Amps (Based on CE Code Part 1, Table 2; derated per Table 5C for 5 or more conductors)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 14/6C W/GND AIA TECK90 600V HL RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Complex Industrial Control Loops: Wiring multi-conductor signaling loops between local control stations, selector switches, pilot lights, and PLC I/O cabinets.

  • Multi-Function Motor Stations: Providing power, start/stop signaling, auxiliary run-status interlocks, and fault feedback to localized motor starter stations.

  • Chemical & Processing Plants: Multi-point discrete signaling, interlocks, and auxiliary feeds routed through corrosive processing floors and pump rooms.

  • Direct Burial & Trench Feeds: Running underground control circuits directly into outbuildings, valve actuator skids, and outdoor process equipment without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.80 in. / 20.32 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 6
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 20
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.316 lb

Real World Applications

Real World Applications

  • Multi-Button Push-Button Stations: Connecting local start, stop, jog, and forward/reverse operator stations with status illumination back to motor control centers.
  • Automated Valve Actuators: Supplying power alongside multiple limit switch feedback lines to motorized quarter-turn valves in water treatment and process plants.
  • Conveyor Safety & E-Stop Systems: Daisy-chaining continuous emergency-stop pull-cords, trip indicators, and slack-cable safety switches along material handling lines.
  • Packaging Machine Interlocks: Linking multiple safety gate switches, photoelectric eye sensors, and localized beacon stacks on automated packaging machinery.
  • Mining Skid Instrumentation: Routing multi-conductor control feeds across high-vibration portable crushing and screening units exposed to rocks and moisture.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

14/6 TECK 90 Cable with Ground, Aluminum Interlocked Armor (AIA) 600V

Parent SKU :  14-6TECK90

SKU :  14-6TECK90-250

ALUMINUM INTERLOCKED ARMOR • DOUBLE PVC JACKETED • DIRECT BURIAL RATED
Contact us for price
Ships in 1-2 days

Parent SKU :  14-6TECK90

SKU :  14-6TECK90-250

$700/ea.
$1,392/ea.
$2,769/ea.
$6,887/ea.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

A heavy-duty, multi-conductor armored control cable engineered for industrial processing facilities, chemical plants, pulp and paper mills, steel manufacturing, mines, power generating stations, and commercial installations. Featuring six 14 AWG bare copper circuit conductors (Black with printed numbers) alongside an uninsulated bare copper grounding conductor, this cable is protected by a flexible Aluminum Interlocked Armor (AIA) and dual protective PVC jackets. Rated for 600V and extreme thermal spans from -40°C to +90°C, it delivers superior physical protection, crush resistance, and environmental sealing for direct burial, cable troughs, and open ladder tray runs without requiring rigid conduit.

Engineered for Severe Environments, Direct Trenching, and Industrial Trays

When running multi-device control circuits, push-button stations, and interlock loops through corrosive atmospheres, physical abuse zones, or sub-zero northern climates, structural reliability ensures continuous plant uptime. The 14/6 TECK90 Cable eliminates the high material cost, rigid bending limitations, and pull-labor of traditional conduit-and-wire installations. Constructed with moisture-resistant XLPE (RW90) insulation, an inner PVC bedding jacket, flexible interlocked aluminum armor, and a rugged -40°C outer PVC jacket, it withstands heavy mechanical impact, chemical washdowns, and continuous ground moisture.

  • Aluminum Interlocked Armor (AIA): Provides continuous mechanical shielding and impact protection while preserving cable flexibility for complex routing around structural steel and machine frames.

  • Dual-Jacket Environmental Barrier: Built with a lead-free, flame-retardant inner PVC jacket under the armor and a heavy-duty -40°C outer PVC jacket that defends against water ingress, chemical washdowns, sunlight (UV), and outer abrasion.

  • Thermoset RW90 XLPE Insulation: Cross-linked polyethylene insulation maintains dielectric strength up to 90°C and eliminates conductor deformation or insulation flow during thermal spikes.

  • Extreme Cold-Bend Certified: Outer jacket is rated down to -40°C, allowing cold-weather installation, sub-zero pull handling, and winter-grade direct burial without jacket fracturing.

  • Severe Flame-Spread Compliance: Certified to rigorous IEEE 1202, CSA FT4, IEEE 383, and ICEA vertical-tray flame tests (70,000 BTU/hr), preventing vertical fire propagation along industrial tray runs.

Technical Specifications

  • Conductor Size: 14 AWG

  • Number of Conductors: 6 Conductors + 1 Ground

  • Grounding Conductor: 14 AWG uninsulated bare stranded soft drawn copper

  • Conductor Color Code: Black conductors with printed numbers (1 to 6)

  • Conductor Material: Class B stranded bare copper compressed concentric round per ASTM B8

  • Insulation Material: Cross-Linked Polyethylene (XLPE), Type RW90

  • Insulation Thickness: 0.030 inches (0.76 mm)

  • Inner Jacket Material: Lead-free, flame-retardant, moisture- and sunlight-resistant black Polyvinyl Chloride (PVC)

  • Armor Type: Aluminum Interlocked Armor (AIA)

  • Diameter Over Armor: 0.72 inches (18.29 mm)

  • Outer Jacket Material: Black Polyvinyl Chloride (PVC), water, chemical, sunlight, and abrasion resistant (-40°C rated)

  • Nominal Overall Diameter (OD): 0.80 inches (20.32 mm)

  • Approximate Net Weight: 316 lbs / kft (470 kg/km)

  • Ampacity: 20 Amps (Based on CE Code Part 1, Table 2; derated per Table 5C for 5 or more conductors)

  • Voltage Rating: 600 Volts

  • Operating Temperature Range: -40°C to +90°C (-40°F to 194°F)

  • Industry Designation: 14/6C W/GND AIA TECK90 600V HL RW90 PVC -40C/+90C FT4

  • Industry Standards & Approvals: CSA C22.2 No. 131, CSA C22.2 No. 174, CSA FT1 & FT4, IEEE 383 (70,000 BTU/hr), UL 1581 (70,000 BTU/hr), IEEE 1202 (70,000 BTU/hr), ICEA T-30-520 (70,000 BTU/hr), RoHS Compliant

Common Applications

  • Complex Industrial Control Loops: Wiring multi-conductor signaling loops between local control stations, selector switches, pilot lights, and PLC I/O cabinets.

  • Multi-Function Motor Stations: Providing power, start/stop signaling, auxiliary run-status interlocks, and fault feedback to localized motor starter stations.

  • Chemical & Processing Plants: Multi-point discrete signaling, interlocks, and auxiliary feeds routed through corrosive processing floors and pump rooms.

  • Direct Burial & Trench Feeds: Running underground control circuits directly into outbuildings, valve actuator skids, and outdoor process equipment without conduit.

Disclaimer: All values are nominal and subject to standard manufacturing tolerances and manufacturer corrections. Always verify local AHJ, electrical code (CEC / NEC), and engineering guidelines prior to installation.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.80 in. / 20.32 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 6
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 20
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.316 lb

Real World Applications

Real World Applications

  • Multi-Button Push-Button Stations: Connecting local start, stop, jog, and forward/reverse operator stations with status illumination back to motor control centers.
  • Automated Valve Actuators: Supplying power alongside multiple limit switch feedback lines to motorized quarter-turn valves in water treatment and process plants.
  • Conveyor Safety & E-Stop Systems: Daisy-chaining continuous emergency-stop pull-cords, trip indicators, and slack-cable safety switches along material handling lines.
  • Packaging Machine Interlocks: Linking multiple safety gate switches, photoelectric eye sensors, and localized beacon stacks on automated packaging machinery.
  • Mining Skid Instrumentation: Routing multi-conductor control feeds across high-vibration portable crushing and screening units exposed to rocks and moisture.

Disclaimer: Application examples are for planning purposes only. Verify exact job specifications, local AHJ regulations, and code requirements with a licensed engineer or electrician prior to installation.

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 1 PM Central typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. A restocking fee of up to 30% may apply.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 14 AWG
Conductor Material Copper
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 0.80 in. / 20.32 mm
Jacket Type Polyvinyl Chloride (PVC)
Conductor Count 6
Shield Unshielded
Insulation Type Cross-Linked Polyethylene (XLPE)
UL Listing Numbers UL 1581

Technical Specifications

Voltage Rating 600V
Ampacity Rating 20
Direct Burial Rating Yes
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating -40°C to +90°C
Standards CSA C22.2, No. 131
CSA C22.2, No. 174
CSA FT1 and FT4 flame test
IEEE 383 (70, 000 BTU/hr)
UL 1581 (70, 000 BTU/hr)
IEEE 1202 (70, 000 BTU/hr) CSA FT4
ICEA T-30-520 (70, 000 BTU/hr)
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsPower, Control, Lighting Circuits

Packaging & Dimensions:

Weight per Foot 0.316 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

TECK90 cable originated in the Teck mining district of Ontario, Canada, where engineers required an armored, waterproof cable capable of withstanding the punishing mechanical and wet subterranean conditions of deep gold mines. The "90" refers to its 90°C maximum continuous dry/wet operating temperature rating governed by its RW90 cross-linked polyethylene insulation.

It consists of six 14 AWG Class B stranded bare copper conductors insulated with thermoset RW90 XLPE (Black with printed numbers 1–6) alongside an uninsulated 14 AWG bare copper grounding conductor. These conductors are cabled together and bound inside a lead-free, flame-retardant inner PVC bedding jacket, wrapped in Aluminum Interlocked Armor (0.72" diameter), and encased in an abrasion-, chemical-, UV-, and water-resistant black outer PVC jacket (0.80" overall diameter) rated down to -40°C.

A 6-conductor configuration is commonly specified for multi-function machinery drops and dual-actuator control setups. Standard applications include wiring reversing motor starters (forward, reverse, stop, common, and run/fault status lamps), automated motorized valves requiring separate power feeds and open/closed limit feedback switches, and machine safety interlock networks linking multiple e-stops and status beacons to a central control cabinet.

Yes. TECK90 is fully code-certified for direct earth burial. Its dual PVC jackets protect against moisture ingress and soil acids, while the internal Aluminum Interlocked Armor shields the electrical conductors against rocks, soil compaction, and accidental impact from trenching tools.

Standard commercial MC cable typically lacks an inner PVC bedding jacket and often comes without an outer PVC jacket, leaving the bare metal armor exposed to moisture, salts, and corrosive soils. TECK90 features two distinct PVC jackets—one inside the armor and one over the armor—providing a water-tight, chemical-resistant barrier rated down to -40°C that permits direct burial, tray runs, and high-pressure chemical washdowns.

Yes. The outer jacket is rated for installation down to -40°C (-40°F). This ensures the PVC jacket remains pliable during unspooling, pulling, and bending in sub-zero winter conditions without jacket embrittlement or cracking.

Wire America supplies TECK90 by the foot and in standard spools. Whether your project requires an 85-foot run to an automated packaging unit or several thousand feet for an entire plant-wide tray network, we ship exact job-ready lengths to eliminate reel scrap and surplus material costs.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us