Wire Size 14
Conductor Material Copper
Conductor Type Solid
Outer Diameter 0.299 in. / 7.59 mm
Conductor Count 4
Voltage Rating 300V

Get Product Details

Get Product Details

APPLICATION:
NYC Certified Plenum Rated Fire Alarm Cable is used for wiring fire alarms, smoke detectors, voice communications, burglar alarms, and approved for NYC LL39 (formerly LL5) fire protective circuits installed in the City of New York. Applications not to exceed 300 volts, suitable for use up to 200°C.

CONDUCTORS:
Fully annealed solid bare copper per ASTM B3 & B258.

DRAIN WIRE:
Solid 24AWG tinned copper drain wire.

ASSEMBLY:
Insulated conductors cabled together with or without shield under an overall jacket. Ripcord and sequential footage markings to facilitate installation.

CONDUCTOR COLORS:
Pair 1 - Black and Red
Pair 2 - Yellow and Green

JACKET COLOR:
Red

INSULATION:

Premium-grade, color-coded FEP.

The 14/4 Shielded FPLP NYC Appropved Fire Alarm Advantage:

  • LL39 Compliance Guaranteed: Printed with the mandatory NYC-certified legend to ensure your project passes DOB electrical inspections without delays.

  • Heavy-Gauge 4-Conductor Design: The 14 AWG construction provides the power needed for high-output speaker strobes and multi-zone notification appliance circuits (NAC).

  • 100% EMI/RFI Shielding: Features an aluminum/polyester foil shield and tinned copper drain wire to eliminate signal hum and interference from elevator motors and HVAC systems.

  • 200°C FEP Construction: High-performance Fluorinated Ethylene Propylene (FEP) insulation ensures the system remains operational during extreme thermal events, far outperforming standard plenum PVC.

  • Plenum Rated (FPLP): UL-listed for air-handling spaces and high-rise plenums, allowing for a streamlined installation without the need for additional conduit.

Installer’s Note:

"When a project calls for high-output voice evacuation in an NYC mechanical shaft, the 14/4 Shielded FPLP NYC Approved Fire Alarm Cable is the ultimate insurance policy. The 14-gauge copper prevents voltage drop on your longest runs, while the Local Law 39 compliant shield ensures your emergency messages are heard clearly over the building's electrical noise. With a 200°C FEP jacket, you're installing the highest level of survivability available today."


All values are nominal and subject to correction.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14
Conductor Material Copper
Conductor Type Solid
Strand Count 1
Outer Diameter (OD) (in/mm) 0.299 in. / 7.59 mm
Jacket Type Plenum-Rated FEP
Conductor Count 4
Shield Coverage % 1
Shield Type Overall polyester-backed aluminum foil with a solid 24 AWG tinned copper drain wire.
Shield Shielded
Insulation Type (FEP) Fluorinated Ethylene Propylene
UL Listing Numbers UL 13, UL 444, UL1424
Plenum Rating true

Technical Specifications

Voltage Rating 300V
Submersible No
Flexibility Rating Very Good
Temperature Rating 200ºC
Standards NYC Local Law 39 (Formerly LL5)
UL 13 Power-Limited Circuit Cable
UL 444 Communication Cables
UL1424 Cables for Power-Limited Fire-Alarm Circuits
UL Listed Type FPLP, 200°C
NFPA 262 Test for Flame Travel and Smoke of Wires and Cables for Use in Air Handling Spaces
NEC Article 725, 760, 811
Miscellaneous Information All values are nominal and subject to correction.
Other Certifications NYC LL5/LL39
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsNYC LL39 (formerly LL5) fire protective circuits installed in the City of New York.
Common Uses
  • Fire Alarms
  • Smoke Detectors
  • Voice Communications
  • Burglar Alarms

Packaging & Dimensions:

Weight per Foot 0.091 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

PLENUM RATED FIRE ALARM CABLE

Wire America | Wire Flexibility Series

This video shows the construction, jacket and flexibility of the 16-1 Pair and 16-2 Pair Unshielded Plenum Rated Fire Alarm, NY Certified Cables.

14/4 Shielded NYC Approved FPLP Fire Alarm Cable | 200°C LL39

Parent SKU :  FAP-SHDNY14-2P

SKU :  FAP-SHDNY14-2P-500

PLENUM RATED • 200°C HIGH-HEAT • LL39 CERTIFIED • CUT TO LENGTH
In Stock
Ships in 1-2 days

Parent SKU :  FAP-SHDNY14-2P

SKU :  FAP-SHDNY14-2P-500

$829/ea.
$1,649/ea.
Please select an option
Min: 500 ft., Max: 20,000 ft.
Spool (500 ft.)
$829.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

APPLICATION:
NYC Certified Plenum Rated Fire Alarm Cable is used for wiring fire alarms, smoke detectors, voice communications, burglar alarms, and approved for NYC LL39 (formerly LL5) fire protective circuits installed in the City of New York. Applications not to exceed 300 volts, suitable for use up to 200°C.

CONDUCTORS:
Fully annealed solid bare copper per ASTM B3 & B258.

DRAIN WIRE:
Solid 24AWG tinned copper drain wire.

ASSEMBLY:
Insulated conductors cabled together with or without shield under an overall jacket. Ripcord and sequential footage markings to facilitate installation.

CONDUCTOR COLORS:
Pair 1 - Black and Red
Pair 2 - Yellow and Green

JACKET COLOR:
Red

INSULATION:

Premium-grade, color-coded FEP.

The 14/4 Shielded FPLP NYC Appropved Fire Alarm Advantage:

  • LL39 Compliance Guaranteed: Printed with the mandatory NYC-certified legend to ensure your project passes DOB electrical inspections without delays.

  • Heavy-Gauge 4-Conductor Design: The 14 AWG construction provides the power needed for high-output speaker strobes and multi-zone notification appliance circuits (NAC).

  • 100% EMI/RFI Shielding: Features an aluminum/polyester foil shield and tinned copper drain wire to eliminate signal hum and interference from elevator motors and HVAC systems.

  • 200°C FEP Construction: High-performance Fluorinated Ethylene Propylene (FEP) insulation ensures the system remains operational during extreme thermal events, far outperforming standard plenum PVC.

  • Plenum Rated (FPLP): UL-listed for air-handling spaces and high-rise plenums, allowing for a streamlined installation without the need for additional conduit.

Installer’s Note:

"When a project calls for high-output voice evacuation in an NYC mechanical shaft, the 14/4 Shielded FPLP NYC Approved Fire Alarm Cable is the ultimate insurance policy. The 14-gauge copper prevents voltage drop on your longest runs, while the Local Law 39 compliant shield ensures your emergency messages are heard clearly over the building's electrical noise. With a 200°C FEP jacket, you're installing the highest level of survivability available today."


All values are nominal and subject to correction.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 14
Conductor Material Copper
Conductor Type Solid
Strand Count 1
Outer Diameter (OD) (in/mm) 0.299 in. / 7.59 mm
Jacket Type Plenum-Rated FEP
Conductor Count 4
Shield Coverage % 1
Shield Type Overall polyester-backed aluminum foil with a solid 24 AWG tinned copper drain wire.
Shield Shielded
Insulation Type (FEP) Fluorinated Ethylene Propylene
UL Listing Numbers UL 13, UL 444, UL1424
Plenum Rating true

Technical Specifications

Voltage Rating 300V
Submersible No
Flexibility Rating Very Good
Temperature Rating 200ºC
Standards NYC Local Law 39 (Formerly LL5)
UL 13 Power-Limited Circuit Cable
UL 444 Communication Cables
UL1424 Cables for Power-Limited Fire-Alarm Circuits
UL Listed Type FPLP, 200°C
NFPA 262 Test for Flame Travel and Smoke of Wires and Cables for Use in Air Handling Spaces
NEC Article 725, 760, 811
Miscellaneous Information All values are nominal and subject to correction.
Other Certifications NYC LL5/LL39
RoHS Compliance Yes

Usage & Installation

Primary ApplicationsNYC LL39 (formerly LL5) fire protective circuits installed in the City of New York.
Common Uses
  • Fire Alarms
  • Smoke Detectors
  • Voice Communications
  • Burglar Alarms

Packaging & Dimensions:

Weight per Foot 0.091 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
PLENUM RATED FIRE ALARM CABLE

Wire America | Wire Flexibility Series

This video shows the construction, jacket and flexibility of the 16-1 Pair and 16-2 Pair Unshielded Plenum Rated Fire Alarm, NY Certified Cables.

Physical Specifications

Wire Size (AWG/MCM) 14
Conductor Material Copper
Conductor Type Solid
Strand Count 1
Outer Diameter (OD) (in/mm) 0.299 in. / 7.59 mm
Jacket Type Plenum-Rated FEP
Conductor Count 4
Shield Coverage % 1
Shield Type Overall polyester-backed aluminum foil with a solid 24 AWG tinned copper drain wire.
Shield Shielded
Insulation Type (FEP) Fluorinated Ethylene Propylene
UL Listing Numbers UL 13, UL 444, UL1424
Plenum Rating true

Technical Specifications

Voltage Rating 300V
Submersible No
Flexibility Rating Very Good
Temperature Rating 200ºC
Standards NYC Local Law 39 (Formerly LL5)
UL 13 Power-Limited Circuit Cable
UL 444 Communication Cables
UL1424 Cables for Power-Limited Fire-Alarm Circuits
UL Listed Type FPLP, 200°C
NFPA 262 Test for Flame Travel and Smoke of Wires and Cables for Use in Air Handling Spaces
NEC Article 725, 760, 811
Miscellaneous Information All values are nominal and subject to correction.
Other Certifications NYC LL5/LL39
RoHS Compliance Yes

Usage & Installation:

Primary ApplicationsNYC LL39 (formerly LL5) fire protective circuits installed in the City of New York.
Common Uses
  • Fire Alarms
  • Smoke Detectors
  • Voice Communications
  • Burglar Alarms

Packaging & Dimensions:

Weight per Foot 0.091 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

New York City requires fire alarm cables to meet specific standards beyond standard NEC rules, specifically Local Law 39 (LL39) and Local Law 5. This means the cable must feature specialized insulation (like FEP or ECTFE) that is flame-retardant and low-smoke, often with a higher temperature rating (150°C to 200°C) than standard fire alarm wire.

Unshielded: Ideal for most standard notification appliance circuits (NACs) and pull stations where electromagnetic interference (EMI) is not a concern.

Shielded: Required for data communication links (SLC loops) or installations near high-voltage lines, elevator motors, or fluorescent lighting to prevent signal interference and false alarms.

14/4 NYC Approved Fire Alarm Cable is a heavy-duty, four-conductor plenum cable designed for high-current applications and exceptionally long wire runs. In the strict NYC construction environment, 14 AWG is often the mandated minimum for notification circuits in large-scale commercial buildings.

In the NYC market, 14/4 cable is specifically utilized for:

  • High-Output Notification Appliance Circuits (NACs): Used to power large banks of strobes, horns, and speakers. The thicker 14 AWG copper ensures that devices at the very end of a long hallway or on the highest floor of a skyscraper receive full power.
  • Fire Alarm Control Panel (FACP) Power: Frequently used to provide the primary or secondary power connections to fire alarm sub-panels and booster power supplies.
  • Complex Relay and Control Functions: The four conductors (14/4) allow for controlling multiple high-draw functions in one pull, such as large smoke damper actuators, elevator group recall, and high-capacity door release systems.
  • Long-Distance "Class A" Loops: When a project requires a return loop (Class A) over a massive distance, 14/4 provides the lowest resistance, ensuring the system remains fully operational without signal degradation.

Important Note: Consult Your Licensed NYC Electrician
While our cables are NYC Approved and manufactured to meet Local Law 39 standards, fire alarm requirements can vary based on your specific building type, occupancy, and the latest FDNY bulletins.

NYC Approved FPLP (Plenum): Must be used in "plenum" spaces—areas used for air circulation, like above drop ceilings or under raised floors. These have a low-smoke, high-fire-resistance jacket.

NYC Approved FPLR (Riser): Used for vertical runs between floors (risers). In NYC, most commercial specs call for FPLP even in non-plenum areas for maximum safety, but check your specific building code.

14 AWG is typically used for long-distance notification runs or "high-draw" circuits. In large NYC commercial buildings, 14 AWG ensures that sirens and strobes at the end of a long hallway receive the full voltage required to operate during an emergency.

Important Note: Consult Your Licensed NYC Electrician
While our cables are NYC Approved and manufactured to meet Local Law 39 standards, fire alarm requirements can vary based on your specific building type, occupancy, and the latest FDNY bulletins.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us