4-4-4 Triplex Aluminum Overhead Service Drop Cable (Periwinkle)

Parent SKU :  PER-3SDP

SKU :  PER-3SDP-250

600 VOLT SUNLIGHT RESISTANT XLPE JACKET WITH BARE NEUTRAL MESSENGER.
Wire Size 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 0.67 in.
Conductor Count 2
Voltage Rating 600
Ampacity Rating 115

Get Product Details

Get Product Details

"The industry standard for 120/240V single-phase overhead utility drops, residential main power feeds, and temporary jobsite distribution. Engineered for dependable 600V aerial power delivery from utility lines to building weatherheads, this 3-conductor triplex cable features two insulated aluminum phase conductors, weather-resistant XLP insulation, and a heavy-duty bare steel-reinforced ACSR neutral messenger built to withstand environmental strain."

Key Features & Benefits: 4-4-4 Triplex Overhead Service Drop Cable

The 4-4-4 Periwinkle Triplex Cable is the go-to choice for overhead single-phase 120/240V secondary power distribution requiring higher current capacity than standard #6 wire. Designed to span overhead gaps from utility pole transformers to residential weatherheads and service masts, it provides a balanced, sag-resistant solution for main service drops and temporary construction power feeds.

By pairing two 7-strand 1350-H19 series aluminum phase conductors with a high-tensile ACSR neutral messenger, Periwinkle triplex provides lightweight, low-maintenance power delivery with exceptional physical strength. The cross-linked polyethylene (XLP) insulation offers superior protection against sunlight, freezing rain, and severe atmospheric wear.

  • 600V Aerial Reliability: Rated for continuous 120/240V aerial service (up to 600V max phase-to-phase) at conductor temperatures up to 90°C with XLP insulation.

  • High-Tensile ACSR Messenger: Features a 6/1 steel-reinforced ACSR neutral messenger delivering 1,860 lbs of breaking strength to prevent sag and withstand heavy ice and wind loads.

  • Sunlight & Weather-Resistant XLP: Heavy-duty black cross-linked polyethylene insulation prevents UV degradation, cracking, and moisture damage in outdoor environments.

  • Cut to Length by the Foot: Order only the exact span length needed for your project, eliminating jobsite waste and unused spools.

Technical Specifications: 4-4-4 Triplex Overhead Cable

  • Application: Overhead secondary power drops (120/240V single-phase) from utility pole to weatherhead, temporary jobsite power, and outbuilding service feeds.

  • Code Word: Periwinkle.

  • Voltage Rating: 600 Volts Maximum (Phase-to-Phase).

  • Phase Conductors Size & Stranding: Two (2) #4 AWG (7-strand 1350-H19 Series Aluminum).

  • Neutral Messenger Size & Stranding: One (1) #4 AWG ACSR (6 Aluminum / 1 Steel Strand).

  • Messenger Breaking Strength: 1,860 lbs.

  • Insulation Material: Black Cross-Linked Polyethylene (XLP).

  • Insulation Thickness: 0.045 inches (1.14 mm).

  • Nominal Outer Diameter: 0.67 inches.

  • Approximate Cable Weight: 172 lbs per 1,000 ft.

  • Ampacity (90°C XLP Conductor): 115 Amps.

  • Ampacity (75°C Poly Conductor): 90 Amps.

  • Compliance & Standards: ASTM B-230, ASTM B-231, ASTM B-232, ICEA S-76-474, RUS Accepted.

Common 4-4-4 Triplex Overhead Cable Applications

  • Residential Overhead Service Drops: 120/240V single-phase power runs from utility pole transformers to residential weatherheads or outbuilding subpanels.

  • Temporary Construction Power: Heavy-duty overhead power delivery for temporary service poles and main jobsite power distribution panels.

  • Agricultural & Detached Buildings: Aerial power supply to workshops, barns, and detached garages requiring up to 115A capacity.



Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity Reference: Based on conductor temperature of 90°C for XLP (75°C for Poly), 40°C ambient temperature, 0.9 emissivity, and 2 ft/sec wind in full sun. Reference applicable NEC articles for site-specific installation guidelines.

 

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.67 in.
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 115
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350–H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399 Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors
ICEA S-76-474 Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction *Designated sizes are ACSR 6/1, diameter, equivalent resistivity per ASTM B399 for 6201. **Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC, emissivity 0.9; 2ft/sec. wind in sun.

Usage & Installation

Primary ApplicationsOverhead Electrical Service
Common Uses
  • Residential Power Supply
  • Commercial and Industrial Power Supply
  • Temporary Service for Construction Sites
  • Outdoor Lighting
  • Secondary Distribution Between Poles.

Packaging & Dimensions:

Weight per Foot 0.172 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Aluminum Triplex Service Drop Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 6 AWG Voluta Aluminum Triplex Service Drop Cable.

4-4-4 Triplex Aluminum Overhead Service Drop Cable (Periwinkle)

Parent SKU :  PER-3SDP

SKU :  PER-3SDP-250

600 VOLT SUNLIGHT RESISTANT XLPE JACKET WITH BARE NEUTRAL MESSENGER.
In Stock
Ships in 1-2 days

Parent SKU :  PER-3SDP

SKU :  PER-3SDP-250

$276/ea.
$549/ea.
$1,092/ea.
$1.12/ft.
Please select an option
Min: 100 ft., Max: 10,000 ft.
Spool (250 ft.)
$276.00
Please select an option
Maximum reached, contact us for custom orders
Contact Us
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

"The industry standard for 120/240V single-phase overhead utility drops, residential main power feeds, and temporary jobsite distribution. Engineered for dependable 600V aerial power delivery from utility lines to building weatherheads, this 3-conductor triplex cable features two insulated aluminum phase conductors, weather-resistant XLP insulation, and a heavy-duty bare steel-reinforced ACSR neutral messenger built to withstand environmental strain."

Key Features & Benefits: 4-4-4 Triplex Overhead Service Drop Cable

The 4-4-4 Periwinkle Triplex Cable is the go-to choice for overhead single-phase 120/240V secondary power distribution requiring higher current capacity than standard #6 wire. Designed to span overhead gaps from utility pole transformers to residential weatherheads and service masts, it provides a balanced, sag-resistant solution for main service drops and temporary construction power feeds.

By pairing two 7-strand 1350-H19 series aluminum phase conductors with a high-tensile ACSR neutral messenger, Periwinkle triplex provides lightweight, low-maintenance power delivery with exceptional physical strength. The cross-linked polyethylene (XLP) insulation offers superior protection against sunlight, freezing rain, and severe atmospheric wear.

  • 600V Aerial Reliability: Rated for continuous 120/240V aerial service (up to 600V max phase-to-phase) at conductor temperatures up to 90°C with XLP insulation.

  • High-Tensile ACSR Messenger: Features a 6/1 steel-reinforced ACSR neutral messenger delivering 1,860 lbs of breaking strength to prevent sag and withstand heavy ice and wind loads.

  • Sunlight & Weather-Resistant XLP: Heavy-duty black cross-linked polyethylene insulation prevents UV degradation, cracking, and moisture damage in outdoor environments.

  • Cut to Length by the Foot: Order only the exact span length needed for your project, eliminating jobsite waste and unused spools.

Technical Specifications: 4-4-4 Triplex Overhead Cable

  • Application: Overhead secondary power drops (120/240V single-phase) from utility pole to weatherhead, temporary jobsite power, and outbuilding service feeds.

  • Code Word: Periwinkle.

  • Voltage Rating: 600 Volts Maximum (Phase-to-Phase).

  • Phase Conductors Size & Stranding: Two (2) #4 AWG (7-strand 1350-H19 Series Aluminum).

  • Neutral Messenger Size & Stranding: One (1) #4 AWG ACSR (6 Aluminum / 1 Steel Strand).

  • Messenger Breaking Strength: 1,860 lbs.

  • Insulation Material: Black Cross-Linked Polyethylene (XLP).

  • Insulation Thickness: 0.045 inches (1.14 mm).

  • Nominal Outer Diameter: 0.67 inches.

  • Approximate Cable Weight: 172 lbs per 1,000 ft.

  • Ampacity (90°C XLP Conductor): 115 Amps.

  • Ampacity (75°C Poly Conductor): 90 Amps.

  • Compliance & Standards: ASTM B-230, ASTM B-231, ASTM B-232, ICEA S-76-474, RUS Accepted.

Common 4-4-4 Triplex Overhead Cable Applications

  • Residential Overhead Service Drops: 120/240V single-phase power runs from utility pole transformers to residential weatherheads or outbuilding subpanels.

  • Temporary Construction Power: Heavy-duty overhead power delivery for temporary service poles and main jobsite power distribution panels.

  • Agricultural & Detached Buildings: Aerial power supply to workshops, barns, and detached garages requiring up to 115A capacity.



Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

Ampacity Reference: Based on conductor temperature of 90°C for XLP (75°C for Poly), 40°C ambient temperature, 0.9 emissivity, and 2 ft/sec wind in full sun. Reference applicable NEC articles for site-specific installation guidelines.

 

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.67 in.
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 115
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350–H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399 Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors
ICEA S-76-474 Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction *Designated sizes are ACSR 6/1, diameter, equivalent resistivity per ASTM B399 for 6201. **Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC, emissivity 0.9; 2ft/sec. wind in sun.

Usage & Installation

Primary ApplicationsOverhead Electrical Service
Common Uses
  • Residential Power Supply
  • Commercial and Industrial Power Supply
  • Temporary Service for Construction Sites
  • Outdoor Lighting
  • Secondary Distribution Between Poles.

Packaging & Dimensions:

Weight per Foot 0.172 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Video thumbnail
Aluminum Triplex Service Drop Cable

Wire America | Wire Flexibility Series

This video shows the flexibility, size, jacket detail, conductor material and stranding of the 6 AWG Voluta Aluminum Triplex Service Drop Cable.

Physical Specifications

Wire Size (AWG/MCM) 4 AWG
Conductor Material Aluminum
Conductor Type Stranded
Strand Count 7
Outer Diameter (OD) (in/mm) 0.67 in.
Conductor Count 2
Shield Unshielded
Insulation Type (XLPE) Cross-Linked Polyethylene

Technical Specifications

Voltage Rating 600
Ampacity Rating 115
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards ASTM B-230 Aluminum 1350–H19 Wire for Electrical Purposes
ASTM B-231 Concentric-Lay-Stranded Aluminum 1350 Conductors
ASTM B-232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
ASTM B-399 Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors
ICEA S-76-474 Neutral-Supported Power Cable Assemblies with Weather-Resistant Extruded Insulation Rated 600 Volts
RUS Accepted
Miscellaneous Information All values are nominal and subject to correction *Designated sizes are ACSR 6/1, diameter, equivalent resistivity per ASTM B399 for 6201. **Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC, emissivity 0.9; 2ft/sec. wind in sun.

Usage & Installation:

Primary ApplicationsOverhead Electrical Service
Common Uses
  • Residential Power Supply
  • Commercial and Industrial Power Supply
  • Temporary Service for Construction Sites
  • Outdoor Lighting
  • Secondary Distribution Between Poles.

Packaging & Dimensions:

Weight per Foot 0.172 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

4-4-4 Triplex cable is designed for 120/240V single-phase aerial power delivery. It features two insulated phase wires and one bare neutral messenger, making it the standard choice for running overhead service drops from utility poles to building weatherheads and powering temporary jobsite meter main poles.

Triplex contains 3 conductors (2 insulated phase wires + 1 bare neutral) for single-phase 120/240V power delivery. Duplex contains only 2 conductors (1 insulated phase wire + 1 bare neutral) for single 120V circuits or outdoor lighting.

No. Triplex service drop wire is engineered strictly for overhead aerial applications. Its XLP insulation is weather- and sunlight-resistant for outdoor exposure, but it is not rated for direct burial or underground conduit installation. For underground service runs, use URD (Underground Residential Distribution) cable or USE-2 wire.

#4 AWG Triplex with XLPE insulation is rated for up to 115 Amps in free-air overhead installations at a 90°C conductor rating. Always consult NEC Table 310.17 / local code requirements and equipment terminal ratings to ensure proper sizing for your project.

Yes! At Wire America, we cut #4 Triplex Overhead Cable to your exact required footage. Simply enter the length you need, and we’ll cut and dispatch it directly to your shop or job-site.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us