350 MCM 3C Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Black, Red, White)

Parent SKU :  PPLEX350-3-BRW

SKU :  PPLEX350-3-BRW-250

XLPE INSULATED • 600/1000V • SUNLIGHT RESISTANT • FACTORY-TWISTED
Wire Size 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter 1.63 in. / 41.40 mm
Conductor Count 3
Voltage Rating 600/1000V
Ampacity Rating 280
Weight per Foot 1.199 lb

Get Product Details

Get Product Details

For projects where massive electrical loads meet challenging job site logistics, this 350 MCM Priority-Plex® assembly provides a high-capacity power solution with a streamlined installation profile. This factory-synchronized twist of three large-gauge conductors eliminates the chaotic management of individual reels and prevents the uneven tensioning often seen when paralleling 350 MCM leads manually, ensuring a balanced and safer pull.

Why Choose 350 MCM 3C Twisted XHHW-2 Aluminum Feeder?

Navigating 350 MCM conductors through tight bends and long conduit runs requires a cable that works with the installer, not against them. The Priority-Plex® system reduces the internal friction within the raceway, while the aluminum construction offers a significant weight reduction that prevents equipment strain and crew fatigue on high-amperage industrial installs.

  • Friction-Reducing Geometry: The twisted design minimizes the total surface area in contact with the conduit, facilitating a much smoother glide than loose, parallel conductors.

  • Rapid Circuit Termination: Equipped with color-coded Black and Red phases and a dedicated White neutral, this assembly removes the guesswork during final panel landing and commissioning.

  • High-Integrity XLP Shielding: The XHHW-2 cross-linked polyethylene insulation is specifically formulated to resist the heat generated by heavy continuous loads and the moisture of underground ducts.

  • Cost-Efficient Power Delivery: Utilizes AA-8000 series aluminum to provide the high ampacity required for large infrastructure at a fraction of the cost and weight of copper.

Technical Specifications: 350 MCM 3C XHHW-2

  • Conductor Size: 350 MCM (kcmil)

  • Number of Conductors: 3 (Twisted)

  • Color Code: Black, Red, White

  • Ampacity: 250 Amps at 75°C / 280 Amps at 90°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Cross-linked Polyethylene (XLP), Type XHHW-2

  • Max Temp: 90°C (Wet/Dry)

  • Conductor Material: AA-8000 Series Aluminum Alloy

  • Standards: UL 44, UL 854, ASTM B800, B801, Federal Spec A-A-59544

Common Applications

  • Commercial Power Hubs: Ideally suited for feeding main distribution switchboards in shopping centers, large retail outlets, and office towers.

  • Industrial Motor Feeds: A preferred choice for supplying high-horsepower industrial equipment and manufacturing assembly lines.

  • Infrastructure Upgrades: Perfect for replacing aged feeder systems in municipal buildings or utility substations where space within existing conduits is limited.

  • Data Center Power Strips: Reliable for the high-density power requirements of server farms and telecommunications hubs requiring consistent neutral support.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

 

PRIORITY PART#: 350-03PPLEX-BRW

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) for conductors in raceway or earth, adjusted for specific ambient conditions and fill factors as applicable.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.63 in. / 41.40 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 280
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 1.199 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

350 MCM 3C Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Black, Red, White)

Parent SKU :  PPLEX350-3-BRW

SKU :  PPLEX350-3-BRW-250

XLPE INSULATED • 600/1000V • SUNLIGHT RESISTANT • FACTORY-TWISTED
Contact us for price
Ships in 1-2 days

Parent SKU :  PPLEX350-3-BRW

SKU :  PPLEX350-3-BRW-250

$0/ea.
$0/ea.
$0/ea.
$0/ea.
$0/ft.
Please select an option
Get A Fast Quote
  • Fast Shipping
  • Competitive Pricing
  • Phone Support

Get Product Details

Get Product Details

For projects where massive electrical loads meet challenging job site logistics, this 350 MCM Priority-Plex® assembly provides a high-capacity power solution with a streamlined installation profile. This factory-synchronized twist of three large-gauge conductors eliminates the chaotic management of individual reels and prevents the uneven tensioning often seen when paralleling 350 MCM leads manually, ensuring a balanced and safer pull.

Why Choose 350 MCM 3C Twisted XHHW-2 Aluminum Feeder?

Navigating 350 MCM conductors through tight bends and long conduit runs requires a cable that works with the installer, not against them. The Priority-Plex® system reduces the internal friction within the raceway, while the aluminum construction offers a significant weight reduction that prevents equipment strain and crew fatigue on high-amperage industrial installs.

  • Friction-Reducing Geometry: The twisted design minimizes the total surface area in contact with the conduit, facilitating a much smoother glide than loose, parallel conductors.

  • Rapid Circuit Termination: Equipped with color-coded Black and Red phases and a dedicated White neutral, this assembly removes the guesswork during final panel landing and commissioning.

  • High-Integrity XLP Shielding: The XHHW-2 cross-linked polyethylene insulation is specifically formulated to resist the heat generated by heavy continuous loads and the moisture of underground ducts.

  • Cost-Efficient Power Delivery: Utilizes AA-8000 series aluminum to provide the high ampacity required for large infrastructure at a fraction of the cost and weight of copper.

Technical Specifications: 350 MCM 3C XHHW-2

  • Conductor Size: 350 MCM (kcmil)

  • Number of Conductors: 3 (Twisted)

  • Color Code: Black, Red, White

  • Ampacity: 250 Amps at 75°C / 280 Amps at 90°C (NEC Table 310.16)

  • Voltage: 600V

  • Insulation: Cross-linked Polyethylene (XLP), Type XHHW-2

  • Max Temp: 90°C (Wet/Dry)

  • Conductor Material: AA-8000 Series Aluminum Alloy

  • Standards: UL 44, UL 854, ASTM B800, B801, Federal Spec A-A-59544

Common Applications

  • Commercial Power Hubs: Ideally suited for feeding main distribution switchboards in shopping centers, large retail outlets, and office towers.

  • Industrial Motor Feeds: A preferred choice for supplying high-horsepower industrial equipment and manufacturing assembly lines.

  • Infrastructure Upgrades: Perfect for replacing aged feeder systems in municipal buildings or utility substations where space within existing conduits is limited.

  • Data Center Power Strips: Reliable for the high-density power requirements of server farms and telecommunications hubs requiring consistent neutral support.


Technical Note: All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.

 

PRIORITY PART#: 350-03PPLEX-BRW

 

*All values are nominal and subject to correction. Ampacity is based on the National Electrical Code (NEC) for conductors in raceway or earth, adjusted for specific ambient conditions and fill factors as applicable.

See Full Specifications

See Full Specifications

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.63 in. / 41.40 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 280
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 1.199 lb

Shipping and Returns

Shipping and Returns

General Shipping Information

In-stock orders placed before 3pm EST typically ship within 1-2 business days. Our business days are Monday through Friday; we do not process orders on Saturday, Sunday, or major US Holidays.

You will receive an e-mail with a tracking number within 1-2 business days from the time its shipped. You will also be able to view your order status and tracking numbers in your account order history.

Expedited Shipping

Expedited shipments are delivered Monday-Friday except on US Holidays. The order must be placed before 12pm CST to ship same day ( Mon-Fri Only).

Returns

You have 30 days from the day you receive the item to contact us for a return. Returns are subject to a 30% Restocking Fee.

Please contact us at help@wireamerica.com to request a return authorization. Have your order number or name the order was placed with ready and we will email you an RMA (return) number and instructions for return. Currently, we do not offer exchanges. A new order must be placed if you need a different item. If you provide the new order number at the time of your return request, the restocking fee may be lowered.

Orders on any items with a material value of $50 or less are non-returnable.

Physical Specifications

Wire Size (AWG/MCM) 350 MCM
Conductor Material Aluminum
Conductor Type Stranded
Outer Diameter (OD) (in/mm) 1.63 in. / 41.40 mm
Conductor Count 3
Shield Unshielded
Insulation Type XLPE
UL Listing Numbers UL 44, UL 1685, UL 2557

Technical Specifications

Voltage Rating 600/1000V
Ampacity Rating 280
Submersible No
Sunlight Resistance Rating Yes
Temperature Rating 90ºC
Standards UL44/C22.2 No.38
UL 1685
UL 2556
ASTM B800
ASTM B801
Miscellaneous Information All values are nominal and subject to correction. Ampacities for aluminum conductors in raceway or cable based on an ambient temperature of 30°C per NEC Table 310.16 for 3 current carrying conductors

Usage & Installation:

Primary ApplicationsPower Distribution, Feeder and Branch Circuits
Common Uses
  • Power Distribution
  • Feeder and Branch Circuits

Packaging & Dimensions:

Weight per Foot 1.199 lb

Have Questions?

Call Us. Icon

Call Us.

(833) 268-8644

Email Us

350 MCM Aluminum is typically specified for 300-amp to 350-amp circuits. While smaller gauges are sufficient for standard residential services, 350 MCM is the workhorse for industrial motor control centers, large commercial HVAC chillers, and high-density apartment sub-panels. It is also the preferred "upsize" for 200A or 250A runs that span long distances (over 250 feet) to counteract the voltage drop that would occur with smaller conductors.

Large-gauge conductors like 350 MCM have significant "memory"—they tend to resist bending and try to spring back to their original shape, which can make managing cable in large junction boxes a nightmare. The Priority-Plex® factory twist helps neutralize this internal tension. Because the conductors are already cabled in a helical formation, the bundle stays together more naturally, making it easier to train into lugs and preventing the "sprawl" that occurs with parallel-laid heavy wires.

At the 300A+ power level, heat dissipation is a major concern. Standard PVC-based wires (like THHN) can become soft or brittle over decades of thermal cycling. This cable uses XLPE (Cross-Linked Polyethylene) insulation, which is a thermoset material. It maintains its structural integrity and dielectric strength even during emergency overloads or high-ambient-temperature conditions, ensuring that your critical industrial power feeds remain stable and safe for the long term.

Since this 3-conductor assembly includes two hots (Black/Red) and a neutral (White), a separate equipment grounding conductor (EGC) is almost always required. According to NEC Table 250.122:

  • For a 300-amp circuit, a #4 AWG copper or #2 AWG aluminum ground is typically required.
  • For a 350-amp circuit, a #3 AWG copper or #1 AWG aluminum ground is required.
    Because this cable is Priority-Plex® twisted, it leaves more room in the conduit to pull that necessary ground wire compared to loose, messy conductors.

While NEC calculations might suggest a 2.5-inch conduit is sufficient for 40% fill, 350 MCM is a very "thick" pull. For a 3-conductor twisted bundle of this size, most professional installers recommend 3-inch or 3.5-inch conduit. This extra space is vital for navigating multiple 90-degree bends and allows the pull to be completed using standard mechanical tuggers without exceeding the cable's maximum sideways pressure limit.

Call Us. Icon

Call Us.

(833) 268-8644

Email Us