{"product_id":"belden-9538-24-awg-8-conductor-shielded-cable","title":"Belden 9538 24 AWG 8-Conductor Shielded Computer Cable | 300V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eBelden 9538 is a premium, high-performance 24 AWG, 8-conductor shielded multi-conductor cable engineered specifically for computer interconnections, data transmission, EIA RS-232 serial configurations, and low-voltage control circuits. Utilizing Belden’s proprietary Beldfoil® aluminum-polyester shield, this cable delivers 100% shielding coverage to safeguard critical data pathways from electromagnetic interference (EMI) and radio frequency interference (RFI) in electronically noisy industrial or office environments.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of Belden 9538\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e100% Beldfoil® Shielding:\u003c\/b\u003e Features a patented aluminum foil-polyester tape shield applied with the foil side facing out. This provides complete structural isolation against high-frequency electrostatic noise, ensuring data integrity over extended runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eIntegrated Drain Wire:\u003c\/b\u003e Equipped with a 24 AWG stranded tinned copper drain wire. This configuration allows installers to easily terminate and ground the shield at terminal blocks without needing to manually untwist or comb out a braided layer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003ePremium Conductor Construction:\u003c\/b\u003e Consists of 8 conductors made from high-conductivity, stranded (\u003cspan class=\"math-inline\" data-math=\"7 \\times 32\" data-index-in-node=\"96\"\u003e7 x 32\u003c\/span\u003e) tinned copper. The tinned coating provides excellent corrosion resistance and enhances solderability at connection points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eSemi-Rigid PVC Insulation:\u003c\/b\u003e The conductors are wrapped in a robust, semi-rigid PVC (SR-PVC) layer, balancing precise electrical insulation properties with high physical resistance to crushing and mechanical wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eFlexible Chrome PVC Jacket:\u003c\/b\u003e Enclosed in a sleek, industrial-grade chrome PVC outer jacket that is highly flame-retardant and offers smooth pulling characteristics through conduit, drop ceilings, or dense equipment racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eEIA RS-232 Serial Data:\u003c\/b\u003e The industry standard wire profile for establishing reliable multi-line serial communication links between computers, PLCs, and peripheral devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eComputer Interconnects:\u003c\/b\u003e Interfaced routing for instrumentation networks, legacy mainframe terminals, and control room data consoles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eInstrumentation \u0026amp; Control:\u003c\/b\u003e Transmitting low-voltage analog signals or digital discrete I\/O pulses from sensors, control panels, and automation arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eLow-Voltage Security Systems:\u003c\/b\u003e Multi-zone alarm links, keypad interconnections, and access control panel wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Belden Standard Color Code Chart\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003e8:\u003c\/b\u003e Yellow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e Belden 9538\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 24 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eConductor Stranding:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"7 \\times 32\" data-index-in-node=\"21\"\u003e7 x 32\u003c\/span\u003e Stranded Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e SR-PVC (Semi-Rigid Polyvinyl Chloride)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eShield Type:\u003c\/b\u003e Beldfoil® Aluminum Foil-Polyester Tape (100% Coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eDrain Wire:\u003c\/b\u003e 24 AWG Stranded Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eOuter Jacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Chrome Gray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 300V RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e -20°C to +80°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e UL1685 FT4 Loading, Vertical Tray Flame Test\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,11,0\"\u003e\u003cb data-path-to-node=\"9,11,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL AWM Style 2464, NEC Article 800 Type CM, CEC Type CMG, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When routing Belden 9538 for RS-232 serial communications, please note that this is a \u003cb data-path-to-node=\"11\" data-index-in-node=\"102\"\u003enon-twisted pair\u003c\/b\u003e cable (conductors are layered in a concentric cabled formation). For standard low-speed serial data or shorter runs, this configuration works perfectly. However, for high-speed differential communication protocols requiring balanced lines—such as RS-422 or RS-485—a twisted-pair cable structure (like Belden 9504) should be selected instead to mitigate cross-talk between adjacent signal legs.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 24 AWG \/ 8-Conductor Shielded Computer Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Systems installation must comply with local building codes, NEC regulations, and specific equipment manufacturer parameters. Always cross-reference the official Belden manufacturer data sheet prior to implementing physical system deployments.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53116331327802,"sku":"BDN9538-250","price":757.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53116331360570,"sku":"BDN9538-500","price":1515.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53116331393338,"sku":"BDN9538-1K","price":2860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Belden-9538.jpg?v=1772671790","url":"https:\/\/www.wireamerica.com\/products\/belden-9538-24-awg-8-conductor-shielded-cable","provider":"Wire America ","version":"1.0","type":"link"}