{"product_id":"belden-5409ue-20-12-unshielded-sound-security-wire","title":"Belden 5409UE 20 AWG 12 Conductor Unshielded Sound \u0026 Security Cable | CMR Riser Rated","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eBelden 5409UE is a commercial-grade, multi-conductor unshielded security and audio cable engineered for high-density, low-voltage installations in commercial and residential environments. Featuring 12 independent 20 AWG conductors, this cable bridges the gap between ultra-compact 22 AWG wiring and heavier 18 AWG options. It is UL-rated as CMR (Communications Riser), making it code-compliant for vertical installations inside riser shafts, between floors, or within walls, offering a balance of data\/power transmission capacity and space-saving routing flexibility.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of Belden 5409UE\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eMid-Gauge 20 AWG Profile:\u003c\/b\u003e Features a 20 AWG conductor size that minimizes voltage drop over mid-to-long installation distances compared to standard 22 AWG cables, without adding the outer bulk of an 18 AWG setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eCMR Riser Safety Rating:\u003c\/b\u003e Certified with a UL 1666 Riser rating. The flame-retardant PVC jacket is engineered to prevent the spread of fire vertically from floor to floor, satisfying strict commercial building code requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eHighly Conductive Stranded Copper:\u003c\/b\u003e Manufactured with premium stranded bare copper conductors (7 x 28 stranding layout). This stranded configuration delivers excellent physical flexibility, allowing it to navigate tight terminal housing configurations and architectural bends cleanly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003ePremium Polypropylene Insulation:\u003c\/b\u003e Conductors are wrapped in a high-dielectric polypropylene (PP) insulation. This thin-wall formulation delivers superior electrical performance and defense against conductor shorting while keeping the overall diameter slim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003eRip Cord Integration:\u003c\/b\u003e Includes a built-in nylon rip cord beneath the jacket, allowing installers to easily score and strip back long sections of the outer sheath without risking damage to the inner conductor insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCommercial Security Systems:\u003c\/b\u003e Interconnecting multi-zone alarm control panels, keypad arrays, access control door strikes, magnetic locks, card readers, and multi-sensor arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eIntercom \u0026amp; PA Systems:\u003c\/b\u003e Routing multi-station voice paths, balanced paging networks, and master control lines in schools, commercial offices, and healthcare complexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSound \u0026amp; Audio Distribution:\u003c\/b\u003e Connecting multi-channel background music networks, low-voltage paging zones, and localized audio controls where line loss needs to be managed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eBackground Control \u0026amp; Signaling:\u003c\/b\u003e Distributing discrete low-voltage digital signals, power-limited relay controls, HVAC sensor loops, thermostat zones, and building automation commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Belden Standard Multi-Conductor Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003e8:\u003c\/b\u003e Yellow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,8,0\"\u003e\u003cb data-path-to-node=\"7,8,0\" data-index-in-node=\"0\"\u003e9:\u003c\/b\u003e Purple\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,9,0\"\u003e\u003cb data-path-to-node=\"7,9,0\" data-index-in-node=\"0\"\u003e10:\u003c\/b\u003e Gray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,10,0\"\u003e\u003cb data-path-to-node=\"7,10,0\" data-index-in-node=\"0\"\u003e11:\u003c\/b\u003e Pink\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,11,0\"\u003e\u003cb data-path-to-node=\"7,11,0\" data-index-in-node=\"0\"\u003e12:\u003c\/b\u003e Tan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e Belden 5409UE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 20 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper (7 x 28 layout)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PP (Polypropylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) with Rip Cord - Gray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 300V RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e -20 degrees C to +75 degrees C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e UL1666 Riser, C(UL) FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e NEC Article 800 Type CMR, CEC Type CMG, California State Fire Marshal Approved, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Because Belden 5409UE is an \u003cb data-path-to-node=\"11\" data-index-in-node=\"44\"\u003eunshielded\u003c\/b\u003e cable, it is highly flexible but lacks defense against high-frequency electromagnetic interference (EMI). To avoid signal degradation, noise coupling, or data corruption, do not route this low-voltage cable parallel to high-voltage AC power lines (120V\/240V or higher) within the same wall cavity or conduit unless separated by an approved physical barrier or a minimum distance of 50 mm (2 inches). If your layout requires installation through drop ceilings utilized for environmental air exchange, the plenum-rated equivalent (Belden 6409UE) must be used instead.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 20 AWG \/ 12-Conductor Stranded Unshielded Riser Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Low-voltage electrical and security installations must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant NFPA fire safety standards. Always cross-reference the official Belden manufacturer data sheet prior to finalizing physical system designs.\u003c\/p\u003e","brand":"Omni","offers":[{"title":"500 ft. Spool","offer_id":53532117926202,"sku":"BDN5409UE-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532117958970,"sku":"BDN5409UE-1K","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/belden-5409ue-20-awg-12-conductor-stranded-unshielded-cmr.jpg?v=1779982821","url":"https:\/\/www.wireamerica.com\/products\/belden-5409ue-20-12-unshielded-sound-security-wire","provider":"Wire America","version":"1.0","type":"link"}