{"product_id":"belden-5304ue-18-6-unshielded-sound-security-wire","title":"Belden 5304UE 18 AWG 6 Conductor Unshielded Sound \u0026 Security Cable | CMR Riser Rated","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eBelden 5304UE is a commercial-grade, multi-conductor unshielded security and audio cable engineered for multi-circuit, low-voltage control and signal distribution. Featuring 6 independent 18 AWG conductors, this heavy-duty cable handles higher current demands and longer cable runs with significantly less voltage drop than standard 22 AWG options. It is UL-rated as CMR (Communications Riser), making it code-compliant for vertical paths inside riser shafts, between floors, or within walls, bundling multiple zones or control circuits into a single structured pull.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of Belden 5304UE\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 18 AWG Wire Gauge:\u003c\/b\u003e Built with robust 18 AWG conductors to support longer installation distances and minimize line resistance, ensuring reliable power and signal distribution over extended runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e6-Conductor Distribution Layout:\u003c\/b\u003e Combines 6 discrete, color-coded circuits under a single outer sheath, drastically lowering physical deployment time, labeling logistics, and conduit congestion compared to pulling multiple individual wire pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCMR Riser Safety Rating:\u003c\/b\u003e Certified with a UL 1666 Riser rating. The flame-retardant outer PVC jacket is engineered to prevent the spread of fire vertically from floor to floor, satisfying strict commercial building code requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHighly Conductive Stranded Copper:\u003c\/b\u003e Manufactured with premium stranded bare copper conductors in a 7x26 stranding layout. This design balances robust cross-sectional mass with optimal physical flexibility for neat routing through walls and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003ePremium Polypropylene Insulation:\u003c\/b\u003e Conductors are wrapped in a high-dielectric polypropylene (PP) insulation. This thin-wall formulation delivers superior electrical performance and defense against conductor shorting while keeping the overall diameter slim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eRip Cord Integration:\u003c\/b\u003e Includes a built-in nylon rip cord beneath the jacket, allowing installers to easily score and strip back long sections of the outer sheath without risking damage to the inner conductor insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCommercial Security \u0026amp; Access Control:\u003c\/b\u003e Interconnecting access control nodes, keypad arrays, card readers, biometric scanners, and heavy-duty magnetic locks or door strikes requiring low-voltage power supply loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eIntercom \u0026amp; PA Systems:\u003c\/b\u003e Routing multi-station voice paths, balanced paging networks, and master control lines in schools, commercial offices, and healthcare complexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSound \u0026amp; Audio Distribution:\u003c\/b\u003e Connecting multi-channel background music networks, low-voltage paging zones, and localized audio controls where line loss needs to be managed over extended distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eBackground Control \u0026amp; Signaling:\u003c\/b\u003e Distributing multi-circuit low-voltage digital signals, power-limited relay controls, HVAC sensor loops, thermostat zones, and building automation commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Belden Multi-Conductor Color Code Chart\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e Belden 5304UE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper (7x26 layout)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PP (Polypropylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) with Rip Cord - Gray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eNominal Outer Diameter:\u003c\/b\u003e 0.202 inches (5.13 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 300V RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e -20 degrees C to +75 degrees C (Operating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e UL1666 Riser, FT4, IEC 60332-1-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,11,0\"\u003e\u003cb data-path-to-node=\"9,11,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e NEC Article 800 Type CMR, CEC Type CMG, California State Fire Marshal Approved, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Because Belden 5304UE is an \u003cb data-path-to-node=\"11\" data-index-in-node=\"44\"\u003eunshielded\u003c\/b\u003e cable, it is highly flexible but lacks defense against high-frequency electromagnetic interference (EMI). To avoid signal degradation, noise coupling, or data corruption, do not route this low-voltage cable parallel to high-voltage AC power lines (120V\/240V or higher) within the same wall cavity or conduit unless separated by an approved physical barrier or a minimum distance of 50 mm (2 inches). If your layout requires installation through drop ceilings utilized for environmental air exchange, the plenum-rated equivalent (Belden 6304UE) must be used instead.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 6-Conductor Stranded Unshielded Riser Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Low-voltage electrical and security installations must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant NFPA fire safety standards. Always cross-reference the official Belden manufacturer data sheet prior to finalizing physical system designs.\u003c\/p\u003e","brand":"Omni","offers":[{"title":"500 ft. Spool","offer_id":53532291924282,"sku":"BDN5304UE-500","price":309.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532291957050,"sku":"BDN5304UE-1K","price":615.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/belden-5304ue-18-awg-6-conductor-stranded-unshielded-cmr.jpg?v=1779991355","url":"https:\/\/www.wireamerica.com\/products\/belden-5304ue-18-6-unshielded-sound-security-wire","provider":"Wire America","version":"1.0","type":"link"}