{"product_id":"belden-5205ue-16-7-unshielded-sound-security-wire","title":"Belden 5205UE 16 AWG 7 Conductor Unshielded Sound \u0026 Security Cable | CMR Riser Rated","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eBelden 5205UE is a commercial-grade, multi-conductor unshielded security and audio cable engineered for high-density, low-voltage installations requiring enhanced current capacity and robust signal distribution. Featuring 7 independent 16 AWG conductors, this cable provides an excellent solution for complex low-voltage systems that require more power or lower signal loss than standard 18 AWG or 22 AWG options. It is UL-rated as CMR (Communications Riser), making it safe and code-compliant for vertical paths between floors, inside riser shafts, or within walls.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of Belden 5205UE\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHigh-Capacity 16 AWG Profile:\u003c\/b\u003e Built with larger 16 AWG conductors to support longer cable runs and higher current demands with minimal voltage drop, bridging the gap between standard signal wires and heavy-gauge power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e7-Conductor Control Layout:\u003c\/b\u003e Combines 7 discrete circuits into a single outer jacket, significantly reducing cable management complexity and installation time during multi-device or multi-zone drop layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eCMR Riser Safety Rating:\u003c\/b\u003e Certified with a UL 1666 Riser rating. The flame-retardant PVC jacket is engineered to prevent the spread of fire vertically from floor to floor, satisfying strict commercial building code requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHighly Conductive Stranded Copper:\u003c\/b\u003e Manufactured with premium stranded bare copper conductors in a 19x29 stranding layout. This configuration delivers excellent electrical conductivity while remaining physically flexible for effortless routing through wall cavities and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,4,0\"\u003e\u003cb data-path-to-node=\"3,4,0\" data-index-in-node=\"0\"\u003ePremium Polypropylene Insulation:\u003c\/b\u003e Conductors are wrapped in a high-dielectric polypropylene (PP) insulation. This thin-wall formulation delivers superior electrical performance and defense against conductor shorting while keeping the overall diameter slim.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,5,0\"\u003e\u003cb data-path-to-node=\"3,5,0\" data-index-in-node=\"0\"\u003eRip Cord Integration:\u003c\/b\u003e Includes a built-in nylon rip cord beneath the jacket, allowing installers to easily score and strip back long sections of the outer sheath without risking damage to the inner conductor insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCommercial Security \u0026amp; Access Control:\u003c\/b\u003e Interconnecting multi-device access control nodes, keypad arrays, card readers, biometric scanners, and heavy-duty magnetic locks or door strikes requiring low-voltage power supply loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eIntercom \u0026amp; PA Systems:\u003c\/b\u003e Routing multi-station voice paths, balanced paging networks, and master control lines in schools, commercial offices, and healthcare complexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSound \u0026amp; Audio Distribution:\u003c\/b\u003e Connecting multi-channel background music networks, low-voltage paging zones, and localized audio controls where line loss needs to be managed over extended distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eBackground Control \u0026amp; Signaling:\u003c\/b\u003e Distributing multi-circuit low-voltage digital signals, power-limited relay controls, HVAC sensor loops, thermostat zones, and building automation commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Belden Standard Multi-Conductor Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003ePart Number:\u003c\/b\u003e Belden 5205UE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 16 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper (19x29 layout)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PP (Polypropylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) with Rip Cord - Gray\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 300V RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e -20 degrees C to +75 degrees C (Operating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e UL1666 Riser, FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e NEC Article 800 Type CMR, CEC Type CMG, California State Fire Marshal Approved, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Because Belden 5205UE is an \u003cb data-path-to-node=\"11\" data-index-in-node=\"44\"\u003eunshielded\u003c\/b\u003e cable, it is highly flexible but lacks defense against high-frequency electromagnetic interference (EMI). To avoid signal degradation, noise coupling, or data corruption, do not route this low-voltage cable parallel to high-voltage AC power lines (120V\/240V or higher) within the same wall cavity or conduit unless separated by an approved physical barrier or a minimum distance of 50 mm (2 inches). If your layout requires installation through drop ceilings utilized for environmental air exchange, the plenum-rated equivalent (Belden 6205UE) must be used instead.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 16 AWG \/ 7-Conductor Stranded Unshielded Riser Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Low-voltage electrical and security installations must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant NFPA fire safety standards. Always cross-reference the official Belden manufacturer data sheet prior to finalizing physical system designs.\u003c\/p\u003e","brand":"Omni","offers":[{"title":"500 ft. Spool","offer_id":53532293562682,"sku":"BDN5205UE-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532293595450,"sku":"BDN5205UE-1K","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/belden-5205ue-16-awg-7-conductor-stranded-unshielded-cmr.jpg?v=1779996753","url":"https:\/\/www.wireamerica.com\/products\/belden-5205ue-16-7-unshielded-sound-security-wire","provider":"Wire America","version":"1.0","type":"link"}