{"product_id":"8-2-unshielded-substation-control-cable-20-10-pe-pvc","title":"8\/2 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 8 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 8\/2 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 8 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 8 AWG \/ 2-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716349754,"sku":"SUB8-2-45\/15-250","price":1052.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716382522,"sku":"SUB8-2-45\/15-500","price":2093.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716415290,"sku":"SUB8-2-45\/15-1K","price":4164.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716448058,"sku":"SUB8-2-45\/15-FT","price":4.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/8-2-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779841013","url":"https:\/\/www.wireamerica.com\/products\/8-2-unshielded-substation-control-cable-20-10-pe-pvc","provider":"Wire America","version":"1.0","type":"link"}