{"product_id":"750-mcm-4-conductor-w-3-0-grnd-xhhw-2-aluminum-feeder-cable","title":"750 MCM 4C w\/ 3\/0 Ground Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Brown, Orange, Yellow, Gray, Green)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 750 MCM 4-conductor Priority-Plex® assembly with an integrated 3\/0 Ground is a robust high-voltage feeder solution for 277\/480V 3-phase, 4-wire systems. By factory-twisting the heavy-gauge phases (Brown, Orange, Yellow), the neutral (Gray), and a 3\/0 AWG Green ground, this system provides a complete circuit in a single bundle, maximizing efficiency for industrial-scale installations.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eWhy Choose Priority-Plex® 750 MCM with 3\/0 Ground?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eAt the 750 MCM scale, cables are notoriously difficult to handle due to their weight and bend radius. Priority-Plex® technology eliminates the need to set up five separate reels, which is a massive logistical advantage in tight electrical rooms. The 3\/0 ground is sized to meet NEC requirements for this ampacity, providing a safe ground path while keeping the overall bundle diameter slightly smaller than a full-sized ground version.\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eOptimized Grounding:\u003c\/b\u003e The 3\/0 AWG Green ground is factory-integrated, ensuring a reliable low-impedance ground path while maintaining the most efficient bundle geometry for high-tension pulls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003e480V Phase Identification:\u003c\/b\u003e Permanent, factory-colored insulation (Brown, Orange, Yellow, Gray) provides instant phase identification for high-voltage systems, eliminating the labor and human error associated with field-taping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eSuperior Pulling Efficiency:\u003c\/b\u003e The twisted configuration significantly reduces the risk of \"cable jamming\" (where cables wedge together in a conduit bend), which is a common failure point for large parallel pulls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eRugged XHHW-2 Insulation:\u003c\/b\u003e The cross-linked polyethylene (XLPE) jacket is rated for 90°C and provides superior moisture and chemical resistance, essential for industrial and underground environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eTechnical Specifications: 750 MCM 4C + 3\/0G\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003ePhase\/Neutral Size:\u003c\/b\u003e 750 MCM (kcmil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eGround Size:\u003c\/b\u003e 3\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 5 (Brown, Orange, Yellow, Gray, Green Ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e XHHW-2 (Cross-linked Polyethylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"10\"\u003e435 Amps\u003c\/b\u003e (@ 90°C) | \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"30\"\u003e385 Amps\u003c\/b\u003e (@ 75°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Parallel-Twisted (Priority-Plex®)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIndustrial Primary Feeders:\u003c\/b\u003e Supplying power from main switchgear to 480V distribution panels in manufacturing and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eCommercial Riser Systems:\u003c\/b\u003e Used in high-rise buildings to distribute 480V power to mechanical rooms or floor-level transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eHospitals \u0026amp; Infrastructure:\u003c\/b\u003e Reliable power for mission-critical life-safety systems and heavy medical imaging equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eCentral Utilities:\u003c\/b\u003e Ideal for powering large-scale chillers, cooling towers, and water treatment pumping stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Installing a 5-conductor 750 MCM bundle requires high-capacity pulling equipment. Ensure that the conduit is sized correctly for a 5-wire 750\/3\/0 configuration per NEC Chapter 9. Always use AL9CU-rated mechanical or compression connectors and apply an approved antioxidant compound on all terminations to prevent oxidation and localized heating.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eCABLE CONFIGURATION:\u003c\/b\u003e 4C + 1G (BRN-ORG-YEL-GRY-GRN) Twisted Bundle\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"66\"\u003ePRIORITY PART#:\u003c\/b\u003e 750-04PPLEX-BOYG-3\/0G\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53407324995898,"sku":"PPLEX750-4G-3\/0BOYG-250","price":5664.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53407325028666,"sku":"PPLEX750-4G-3\/0BOYG-500","price":11270.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53407325061434,"sku":"PPLEX750-4G-3\/0BOYG-1K","price":22425.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53407325094202,"sku":"PPLEX750-4G-3\/0BOYG-2500","price":55775.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53407325126970,"sku":"PPLEX750-4G-3\/0BOYG-FT","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/750-mcm-4c-3-0-ground-priority-plex-aluminum-xhhw-2.jpg?v=1777997902","url":"https:\/\/www.wireamerica.com\/products\/750-mcm-4-conductor-w-3-0-grnd-xhhw-2-aluminum-feeder-cable","provider":"Wire America ","version":"1.0","type":"link"}