{"product_id":"700-mcm-4-conductor-w-grnd-xhhw-2-aluminum-feeder-cable","title":"700 MCM 4C w\/ Ground Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Brown, Orange, Yellow, Gray, Green)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 700 MCM 4-conductor Priority-Plex® assembly with an integrated 2\/0 Ground is a heavy-duty, high-voltage feeder solution for 277\/480V 3-phase, 4-wire systems. By factory-twisting the phase conductors (Brown, Orange, Yellow), the neutral (Gray), and a 2\/0 AWG Green ground, this cable provides a complete, code-compliant circuit in a single bundle, significantly reducing installation labor for large industrial applications.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eWhy Choose Priority-Plex® 700 MCM with 2\/0 Ground?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eManaging five individual large-gauge conductors is one of the most physically demanding tasks on an industrial job site. Priority-Plex® technology pre-twists the entire circuit into a uniform geometry. This ensures the 2\/0 ground remains tucked within the bundle, preventing it from getting caught or \"migrating\" during a long conduit pull.\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eOptimized Grounding:\u003c\/b\u003e The 2\/0 AWG Green ground is sized to meet NEC requirements for standard overcurrent protection associated with 700 MCM aluminum, providing a safe, low-impedance ground path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eStreamlined Logistics:\u003c\/b\u003e One reel contains the full circuit. This reduces the footprint in the electrical room and eliminates the need for multiple jack stands and specialized reel-spinning equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003e480V Phase Identification:\u003c\/b\u003e Factory-colored insulation (Brown, Orange, Yellow, Gray) provides permanent phase identification. This removes the labor of field-taping and helps prevent high-voltage wiring errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eRugged XHHW-2 Insulation:\u003c\/b\u003e The cross-linked polyethylene (XLPE) jacket is tougher than standard PVC, offering superior resistance to the physical stresses of heavy pulls and a 90°C rating in wet or dry locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eTechnical Specifications: 700 MCM 4C + 2\/0G\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003ePhase\/Neutral Size:\u003c\/b\u003e 700 MCM (kcmil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eGround Size:\u003c\/b\u003e 2\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 5 (Brown, Orange, Yellow, Gray, Green Ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e XHHW-2 (Cross-linked Polyethylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"10\"\u003e425 Amps\u003c\/b\u003e (@ 90°C) | \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"30\"\u003e375 Amps\u003c\/b\u003e (@ 75°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Parallel-Twisted (Priority-Plex®)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIndustrial Main Feeders:\u003c\/b\u003e Supplying power from switchgear to large motor control centers (MCCs) and heavy machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eHigh-Rise Utility Risers:\u003c\/b\u003e Ideal for vertical distribution of 480V power to mechanical floors or secondary transformers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eData Centers:\u003c\/b\u003e Reliable 480V distribution for large UPS systems and industrial-grade cooling plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eInstitutional Facilities:\u003c\/b\u003e Primary service feeders for hospitals, universities, and government complexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Installing a 5-conductor 700 MCM bundle requires high-capacity pulling equipment. Ensure that the conduit is sized correctly for the diameter of the 700 MCM phases plus the 2\/0 ground per NEC Chapter 9. Use only AL9CU-rated mechanical or compression connectors and apply an approved antioxidant compound on all terminations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eCABLE CONFIGURATION:\u003c\/b\u003e 4C + 1G (BRN-ORG-YEL-GRY-GRN) Twisted Bundle\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"66\"\u003ePRIORITY PART#:\u003c\/b\u003e 700-04PPLEX-BOYG-2\/0G\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53407324799290,"sku":"PPLEX700-4G-BOYG-250","price":5337.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53407324832058,"sku":"PPLEX700-4G-BOYG-500","price":10619.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53407324864826,"sku":"PPLEX700-4G-BOYG-1K","price":21129.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53407324897594,"sku":"PPLEX700-4G-BOYG-2500","price":52550.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53407324930362,"sku":"PPLEX700-4G-BOYG-FT","price":21.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/700-mcm-4c-ground-priority-plex-aluminum-xhhw-2-boygg.jpg?v=1777998060","url":"https:\/\/www.wireamerica.com\/products\/700-mcm-4-conductor-w-grnd-xhhw-2-aluminum-feeder-cable","provider":"Wire America ","version":"1.0","type":"link"}