{"product_id":"4-0-aluminum-urd-cable-35kv-100-insulation-water-block-1-3-neutral","title":"4\/0 Aluminum URD Cable 35kV 100% Insulation | Water Block 1\/3 Neutral","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4\"\u003e\"The primary trunk line for high-capacity utility grids—engineered with tree-retardant XLPE and dual-layer water blocking for maximum reliability in 35kV main feeder circuits.\"\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5\"\u003eWhy Utilities Specify the 4\/0 35kV URD\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe 4\/0 AWG 35kV URD cable is the industry standard for main primary feeders in underground residential distribution (URD). Designed to carry the bulk load from the substation to local distribution points, this cable is built for high-ampacity performance and extreme environmental durability.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003eDual-Layer Water Block Protection:\u003c\/b\u003e Engineered to eliminate the risk of \"water treeing,\" this cable features a water-blocking compound within the conductor strands and specialized moisture protection in the neutral layer to prevent longitudinal water migration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eTree-Retardant XLPE (TR-XLPE):\u003c\/b\u003e Featuring a 345-mil layer of high-dielectric TR-XLPE insulation, this cable provides superior resistance to the electrochemical stressors found in damp underground environments, significantly extending the system's life cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003e1\/3 Concentric Neutral:\u003c\/b\u003e Utilizing \u003cb data-index-in-node=\"34\" data-path-to-node=\"7,2,0\"\u003e11 x #14 AWG\u003c\/b\u003e annealed bare copper wires, the 1\/3 neutral configuration offers the necessary grounding and fault-path capacity for heavy main-trunk loads while maintaining cost-efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eHigh-Strength 1350-H19 Aluminum:\u003c\/b\u003e The hard-drawn aluminum core is designed to withstand the massive mechanical tension required to pull heavy-gauge 4\/0 cable through long primary duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eCommon 35kV Applications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eMain Primary Feeders:\u003c\/b\u003e The \"backbone\" of the underground grid, carrying power from the substation to residential subdivisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eIndustrial Main Service:\u003c\/b\u003e Delivering high-ampacity 35kV power to large manufacturing plants, data centers, and hospitals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eRenewable Energy Trunks:\u003c\/b\u003e Serving as the main collector cable for utility-scale solar and wind farm infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003ch4 data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eENGINEERING OVERVIEW: 4\/0 AWG MAIN TRUNK DISTRIBUTION\u003c\/b\u003e The 4\/0 AWG 35kV URD cable is an excellent choice for primary distribution requiring maximum current-carrying capacity. With a robust nominal outer diameter of approximately \u003cb data-index-in-node=\"229\" data-path-to-node=\"12\"\u003e1.69\"\u003c\/b\u003e, this cable is engineered for the rigors of direct burial or duct installation in environments where long-term moisture and soil acidity resistance are non-negotiable.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eAPPLICATION:\u003c\/b\u003e Aluminum Conductor MV-105 35kV water-blocked URD cable is primarily used for primary underground power distribution. It is suitable for use in wet or dry locations, installed in underground ducts or via direct burial.\u003c\/p\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eCONDUCTORS:\u003c\/b\u003e 4\/0 AWG Compact or compressed aluminum 1350-H19 in Class B stranding.\u003c\/p\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"15\"\u003eCONDUCTOR WATER BLOCK:\u003c\/b\u003e Interstitial spaces between conductor strands are filled with a water-blocking compound to prevent moisture migration.\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"16\"\u003eINSULATION:\u003c\/b\u003e \u003cb data-index-in-node=\"12\" data-path-to-node=\"16\"\u003eTR-XLPE (Tree-Retardant Cross-Linked Polyethylene)\u003c\/b\u003e in 100% insulation level (345 Mils).\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"17\"\u003eCONCENTRIC NEUTRAL WATER BLOCK:\u003c\/b\u003e Semi-conducting water-swellable tape over the insulation shield or water-swellable powder between the concentric neutral strands.\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"18\"\u003eCONCENTRIC NEUTRAL:\u003c\/b\u003e 11 x #14 AWG Annealed bare copper wires (1\/3 neutral conductivity).\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"19\"\u003eJACKET:\u003c\/b\u003e Sunlight resistant XLPE, black with three red stripes for easy high-voltage phase identification.\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"20\"\u003eINDUSTRY STANDARDS \u0026amp; COMPLIANCE:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"21\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"21,0,0\"\u003eUL 1072:\u003c\/b\u003e Listed as Type MV-105\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"21,1,0\"\u003eICEA S-94-649:\u003c\/b\u003e Concentric Neutral Cables Rated 5 through 46kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"21,2,0\"\u003eAEIC CS8:\u003c\/b\u003e Shielded Power Cables Rated 5 through 46kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"21,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"21,3,0\"\u003eTemperature Ratings:\u003c\/b\u003e 105°C (Normal), 140°C (Emergency), 250°C (Short Circuit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"22\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"22\"\u003eCABLE MARKING:\u003c\/b\u003e PRIORITY WIRE AL TR-XLPE 35KV 100% INSUL LEVEL 345 MILS (UL) E364254 TYPE MV-105 XLPE WB SUN RES.\u003c\/p\u003e\n\u003cp data-path-to-node=\"22\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53296160670010,"sku":"ALURDWB-35K-4\/0-1\/3-250","price":3721.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53296160702778,"sku":"ALURDWB-35K-4\/0-1\/3-500","price":7404.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53296160735546,"sku":"ALURDWB-35K-4\/0-1\/3-1K","price":14733.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53296160768314,"sku":"ALURDWB-35K-4\/0-1\/3-2500","price":36642.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53296160801082,"sku":"ALURDWB-35K-4\/0-1\/3-FT","price":15.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/4-0-aluminum-urd-cable-35kv-100-insulation-water-block-1-3-neutral.jpg?v=1775767563","url":"https:\/\/www.wireamerica.com\/products\/4-0-aluminum-urd-cable-35kv-100-insulation-water-block-1-3-neutral","provider":"Wire America ","version":"1.0","type":"link"}