{"product_id":"3-3c-w-ground-18-8c-generator-cable-ul-type-tc-er-jp-100amp","title":"Generator Cable, 3\/3C w\/ Ground + 18\/8C, 100 Amps, 17kW-24kW, 600V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e3\/3C + 18\/8C w\/ #8 Ground Generator Cable (TC-ER-JP)\u003c\/b\u003e is an all-in-one, composite power and control tray cable engineered specifically for whole-house standby generator installations (such as Generac, Kohler, and Briggs \u0026amp; Stratton) rated between \u003cb data-path-to-node=\"1\" data-index-in-node=\"245\"\u003e17kW and 24kW\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eInstead of pulling separate heavy power feeders and individual control wiring through conduit, this composite cable bundles the main \u003cb data-path-to-node=\"2\" data-index-in-node=\"133\"\u003e100 Amp 240V power lines\u003c\/b\u003e, the \u003cb data-path-to-node=\"2\" data-index-in-node=\"163\"\u003eground line\u003c\/b\u003e, and the \u003cb data-path-to-node=\"2\" data-index-in-node=\"184\"\u003elow-voltage control\/sensing conductors\u003c\/b\u003e under a single, durable outer jacket.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eELECTRICAL AMPACITY \u0026amp; RATING\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCurrent Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"16\"\u003e100 AMPS\u003c\/b\u003e (based on 75°C terminal temperature limits under NEC rules).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eGenerator Compatibility:\u003c\/b\u003e Engineered for \u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"40\"\u003e17kW to 24kW\u003c\/b\u003e residential and light commercial air-cooled or liquid-cooled standby generators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"16\"\u003e600 Volts\u003c\/b\u003e maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eAll-in-One Cable Assembly:\u003c\/b\u003e Combines high-amperage power feeders, ground, and up to 8 control\/utility wires into a single jacketed run, significantly reducing labor and conduit material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eType TC-ER-JP Rated:\u003c\/b\u003e Approved as Tray Cable - Exposed Run with \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"63\"\u003eJoist Pull (JP)\u003c\/b\u003e rating, meaning it can be pulled through joists and open framing without requiring continuous conduit in residential applications (per NEC Article 336).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Outdoor Approved:\u003c\/b\u003e The heavy-duty PVC outer sheath is sunlight\/UV-resistant and rated for direct burial, tray installation, or transition indoors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eFlame \u0026amp; Weather Resistance:\u003c\/b\u003e Rated for cold-bend temperatures down to -40°C and meets strict FT4 \/ IEEE flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCable Layer Architecture (From Core to Outer Sheath)\u003c\/h4\u003e\n\u003col start=\"1\" data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003ePower Conductors (3 x 3 AWG):\u003c\/b\u003e Stranded bare copper cores with THHN\/THWN PVC\/Nylon insulation (typically color-coded Black, Red, White) for carrying full 240V generator output to the Automatic Transfer Switch (ATS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eGround Conductor (1 x 8 AWG):\u003c\/b\u003e Stranded bare copper conductor (Green or bare) for equipment grounding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eControl\/Sensing Conductors (8 x 18 AWG):\u003c\/b\u003e Stranded bare copper wires used for utility sensing, battery charging, transfer switch controls, and generator status monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eFillers \u0026amp; Binder Tape:\u003c\/b\u003e Non-hygroscopic polypropylene fillers and clear mylar binder tape hold the assembly round and tight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eOuter Jacket:\u003c\/b\u003e Heavy-duty, sunlight-resistant, direct-burial PVC jacket (typically black or orange).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003ePower Conductor Size:\u003c\/b\u003e 3 AWG Stranded Copper (3 Conductors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eGround Conductor Size:\u003c\/b\u003e 8 AWG Stranded Copper (1 Conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eControl Conductor Size:\u003c\/b\u003e 18 AWG Stranded Copper (8 Conductors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e PVC with Nylon coating (THHN\/THWN-2 rated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e Sunlight-resistant, moisture-impervious PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003eOverall Outside Diameter:\u003c\/b\u003e Approx. 0.951 in to 0.98 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\"\u003e\u003cb data-path-to-node=\"14,6,0\" data-index-in-node=\"0\"\u003eApproximate Weight:\u003c\/b\u003e ~885 lbs per 1000 feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,7,0\"\u003e\u003cb data-path-to-node=\"14,7,0\" data-index-in-node=\"0\"\u003eTemperature Limits:\u003c\/b\u003e 90°C Dry \/ 75°C Wet (restricted to 75°C terminal rating for 100A ampacity calculations)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,8,0\"\u003e\u003cb data-path-to-node=\"14,8,0\" data-index-in-node=\"0\"\u003eStandards \u0026amp; Listings:\u003c\/b\u003e UL Standard 1277 (Type TC-ER), UL 83, FT4\/IEEE 1202 Flame Rated, NEC Article 336 (TC-ER-JP), RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eTechnical Note Regarding Installation:\u003c\/b\u003e While this cable is rated for open runs inside joists (JP rating) and direct burial outdoors, always check with your local Authority Having Jurisdiction (AHJ). When transitioning from underground or exposed wall surfaces into enclosures or through walls, approved cable glands or strain-relief fittings designed for Type TC cable must be used to maintain weather-tight seals and electrical bonding.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 3\/3C + 18\/8C w\/ 8 AWG Ground Type TC-ER-JP Multi-Conductor Generator Power \u0026amp; Control Cable (600V, 100A)\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. All generator and Automatic Transfer Switch (ATS) installations must comply with the National Electrical Code (NEC), local municipal building codes, and manufacturer instructions, and must be performed by a qualified licensed electrician.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"251 ft. Spool","offer_id":53787146748218,"sku":"GEN-TC8-3-3-250","price":2591.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53787146780986,"sku":"GEN-TC8-3-3-500","price":5155.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53787146813754,"sku":"GEN-TC8-3-3-1K","price":10257.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53787146846522,"sku":"GEN-TC8-3-3-FT","price":10.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/generator-cable-3-3c-ground-18-8c-100a-17kW-24kW.png?v=1784912965","url":"https:\/\/www.wireamerica.com\/products\/3-3c-w-ground-18-8c-generator-cable-ul-type-tc-er-jp-100amp","provider":"Wire America ","version":"1.0","type":"link"}