{"product_id":"3-0-3-conductor-direct-burial-aluminum-mc-cable","title":"3\/0-3C Direct Burial Aluminum MC Cable with Bare Ground (PVC Jacketed)","description":"\u003cp\u003e\u003cstrong\u003e\"Engineered for maximum power capacity and tough underground environments, 3\/0 3-Conductor Direct Burial Aluminum MC Cable delivers complete feeder protection without the added labor or expense of installing underground conduit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis heavy-duty cable features three 3\/0 compact-stranded aluminum conductors and one #4 AWG aluminum ground conductor, protected by an interlocked aluminum armor and covered in a rugged, moisture-proof, UV-resistant PVC outer jacket. Fully approved per NEC Article 330 for direct earth burial, wet locations, and cable tray applications, it is the ultimate cost-effective solution for 150A–175A service distribution, commercial subpanels, and agricultural power runs.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features \u0026amp; Benefits: 3\/0-3\/0-3\/0 Direct Burial MC Cable + Ground\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDirect Burial Approved (No Conduit Required):\u003c\/b\u003e The extruded PVC outer jacket isolates the interlocked aluminum armor from moisture, soil chemicals, and ground rot, allowing you to lay cable directly into open trenches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e3-Conductor High-Amp Layout:\u003c\/b\u003e Features three insulated 3\/0 power legs plus a bare #4 ground—ideal for 3-phase 3-wire delta systems, main service feeds, and heavy machinery runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Stranded AA-8000 Aluminum:\u003c\/b\u003e Built with lightweight AA-8000 series aluminum alloy that reduces overall cable diameter, making it easier to pull through tight bends without sacrificing ampacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSuperior Mechanical Armor:\u003c\/b\u003e The flexible interlocked aluminum armor shields internal wires from soil shifts, sharp rocks, crushed backfill, and physical impacts during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSunlight \u0026amp; Flame Resistant:\u003c\/b\u003e Designed to handle direct exposure to sunlight, wet locations, and indoor\/outdoor transitions seamlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eXHHW-2 XLPE Insulation:\u003c\/b\u003e Inner power cores feature flame-retardant cross-linked polyethylene insulation certified for 90°C wet and dry operational environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cb\u003eSunlight \u0026amp; Flame Resistant:\u003c\/b\u003e Designed to handle direct exposure to sunlight, wet locations, and indoor\/outdoor transitions seamlessly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications: 3\/0-3\/0-3\/0 Alum Direct Bury MC Cable + Ground\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eConductor Size:\u003c\/b\u003e 3\/0 \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eNumber of Power Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Compact Stranded Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e 4 AWG Bare Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePhase Colors (240V):\u003c\/b\u003e Black, White, Red \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInsulation Type:\u003c\/b\u003e XLPE \/ XHHW-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eArmor Type:\u003c\/b\u003e AIA (Aluminum Interlocked Armor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eProtective Outer Jacket:\u003c\/b\u003e PVC - Black (Sunlight \u0026amp; Moisture Resistant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eVoltage Rating:\u003c\/b\u003e 600 Volts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eTemperature Rating:\u003c\/b\u003e -40°C to 90°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAmp Rating (@ 75°C - NEC):\u003c\/b\u003e 155 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAmp Rating (@ 90°C - NEC):\u003c\/b\u003e 175 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.055 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.050 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eApproximate Nominal Outer Diameter:\u003c\/b\u003e 1.63 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eApproximate Net Weight:\u003c\/b\u003e 1,042 lbs per 1,000 ft\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMinimum Bending Radius:\u003c\/b\u003e 11.41 inches \u003ci\u003e(Calculated as 7x Diameter Over Jacket)\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompliance Standards:\u003c\/b\u003e UL 44, UL 1569 (Type MC), NEMA WC70 \/ ICEA S-95-658, IEEE 1202, ASTM B800 \u0026amp; B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommon 3\/0-3 Alum MC Cable PVC Jacket Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCommercial Main Feeders:\u003c\/b\u003e Supplying power from utility disconnects to 150A–200A commercial distribution panels, switchgear arrays, and large subpanels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eIndustrial \u0026amp; Renewable Energy Layouts:\u003c\/b\u003e Routing heavy power across solar fields, manufacturing facilities, wastewater plants, and industrial job sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDirect Burial Site Distribution:\u003c\/b\u003e Laying continuous underground feeder runs between separate commercial structures, agricultural facilities, and outbuildings.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp id=\"p-rc_02093c4c4f149f2c-513\"\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cb\u003eTechnical Note: \u003c\/b\u003eTo prevent structural degradation from galvanic corrosion, installers must utilize dual-rated AL7CU or AL9CU mechanical compression lugs or mechanical split-bolts when joining this aluminum cable to copper busbars or breaker terminals. Penetrox or similar antioxidant joint compound must be thoroughly applied to all bare aluminum conductors before final structural torquing. While the PVC jacket isolates the interior armor against direct soil or chemical contact, minimum trench depth profiles must strictly comply with NEC Article 300.5 tables (typically requiring 24 inches of earth cover for direct-buried cables not under concrete paths, or 18 inches beneath standard structural landscapes).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Large-scale high-voltage feeder systems and underground distribution paths must strictly adhere to the National Electrical Code (NEC), local electrical building enforcement, and relevant safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing structural configurations or executing structural cuts.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53532995748154,"sku":"MCA3\/0-3JKT-250","price":1968.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53532995780922,"sku":"MCA3\/0-3JKT-500","price":3916.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532995813690,"sku":"MCA3\/0-3JKT-1K","price":7791.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53532995846458,"sku":"MCA3\/0-3JKT-FT","price":7.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/3-0-3c-aluminum-mc-cable-direct-burial-pvc-jacketed.jpg?v=1780089630","url":"https:\/\/www.wireamerica.com\/products\/3-0-3-conductor-direct-burial-aluminum-mc-cable","provider":"Wire America ","version":"1.0","type":"link"}