{"product_id":"250-mcm-4-conductor-w-grnd-xhhw-2-aluminum-feeder-cable","title":"250 MCM 4C w\/ Ground Twisted XHHW-2 Aluminum Feeder Cable, Priority-Plex®, (Brown, Orange, Yellow, Gray, Green)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 250 MCM 4-conductor Priority-Plex® assembly with an integrated #1 AWG Ground is a streamlined feeder solution designed for 277\/480V 3-phase, 4-wire systems. By factory-twisting the phase conductors (Brown, Orange, Yellow), the neutral (Gray), and a #1 AWG Green ground into a single synchronized bundle, this cable eliminates the need for managing five separate reels and provides a \"ready-to-pull\" circuit for high-efficiency installations.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eWhy Choose Priority-Plex® 250 MCM with #1 Ground?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"3\"\u003eAt 250 MCM, conductors are often stiff and prone to \"spiraling\" or \"bird-caging\" during parallel pulls. Priority-Plex® technology maintains a consistent bundle geometry, which significantly reduces the coefficient of friction within the conduit and prevents cables from \"wedging\" in 90° bends.\u003c\/p\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eOptimized Grounding:\u003c\/b\u003e The #1 AWG Green ground is factory-integrated and sized to meet NEC requirements for standard 480V circuits, providing a safe low-impedance ground path while maintaining a compact overall bundle diameter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003e480V Phase Identification:\u003c\/b\u003e Permanent, factory-colored insulation (Brown, Orange, Yellow, Gray, Green) provides instant phase identification. This removes the labor-intensive requirement for field-taping and reduces the risk of phase-rotation or grounding errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eRapid Installation:\u003c\/b\u003e One reel replaces five. This reduces setup time, requires fewer jack stands, and allows a smaller crew to manage large-scale commercial or industrial pulls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eXHHW-2 Durability:\u003c\/b\u003e The cross-linked polyethylene (XLPE) insulation is rugged and moisture-resistant, offering a higher melting point and superior protection during high-tension pulls compared to PVC-based insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eTechnical Specifications: 250 MCM 4C + #1G\u003c\/h4\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003ePhase\/Neutral Size:\u003c\/b\u003e 250 MCM (kcmil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eGround Size:\u003c\/b\u003e #1 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 5 (Brown, Orange, Yellow, Gray, Green Ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e XHHW-2 (Cross-linked Polyethylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"10\"\u003e230 Amps\u003c\/b\u003e (@ 90°C) | \u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"30\"\u003e205 Amps\u003c\/b\u003e (@ 75°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Parallel-Twisted (Priority-Plex®)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eCommercial 480V Feeders:\u003c\/b\u003e Main and sub-feeders for office buildings, hospitals, and large retail centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eIndustrial Motor Loads:\u003c\/b\u003e Supplying 3-phase power to motor control centers (MCCs) and medium-to-large industrial equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eData Center Power:\u003c\/b\u003e Efficient distribution for high-voltage server racks, UPS systems, and cooling infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eEV Charging Infrastructure:\u003c\/b\u003e Primary feed for Level 3 DC fast-charging banks in commercial parking structures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When terminating 250 MCM aluminum, always use AL9CU-rated mechanical or compression connectors. It is vital to wire-brush the conductor and apply an approved antioxidant joint compound to ensure long-term connection integrity and prevent surface oxidation. Always verify that the conduit size is adequate for a 5-conductor twisted bundle per NEC Chapter 9.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eCABLE CONFIGURATION:\u003c\/b\u003e 4C + 1G (BRN-ORG-YEL-GRY-GRN) Twisted Bundle\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"66\"\u003ePRIORITY PART#:\u003c\/b\u003e 250-04PPLEX-BOYG-1G\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53407322145082,"sku":"PPLEX250-4G-BOYG-250","price":1995.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53407322177850,"sku":"PPLEX250-4G-BOYG-500","price":3969.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53407322210618,"sku":"PPLEX250-4G-BOYG-1K","price":7898.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53407322243386,"sku":"PPLEX250-4G-BOYG-2500","price":19643.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53407322276154,"sku":"PPLEX250-4G-BOYG-FT","price":8.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/250-mcm-4c-gray-neutral-green-ground-priority-plex-aluminum-xhhw-2.jpg?v=1777998701","url":"https:\/\/www.wireamerica.com\/products\/250-mcm-4-conductor-w-grnd-xhhw-2-aluminum-feeder-cable","provider":"Wire America ","version":"1.0","type":"link"}