{"product_id":"2-awg-diesel-locomotive-cable-2kv","title":"2 AWG Diesel Locomotive Cable, 2000V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e2 AWG Diesel Locomotive Cable (DLO)\u003c\/b\u003e is an industrial-grade, single-conductor portable power cable designed for high-stress electrical equipment and rugged power distribution configurations. Engineered to operate under a maximum continuous rating of \u003cb data-path-to-node=\"1\" data-index-in-node=\"249\"\u003e2000 Volts\u003c\/b\u003e, this heavy-duty power line is built to survive constant vibration, tight bend profiles, and severe environmental abuse.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eWhile originally engineered to transmit raw energy from traction generators to drive motors in diesel-electric locomotives, its supreme durability has made it a preferred choice for stationary and mobile applications. It functions as a flexible alternative to standard building wire (like THHN or XHHW) in situations requiring a tight bending radius or dynamic movement.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eELECTRICAL AMPACITY \u0026amp; PERFORMANCE DATA\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eDue to its high-density stranding and specialized dual-layer insulation profile, DLO cable exhibits excellent heat dissipation and high-current capacity limits:\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMaximum Current Capacity (30 degrees C Ambient Air): 190 AMPS\u003c\/b\u003e This threshold is calculated using a continuous 90 degrees C conductor temperature operating in open-air trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eNational Electrical Code Adjustments:\u003c\/b\u003e When grouping multiple single-conductor DLO lines in closed structural conduits, wire troughs, or tight raceways, installers must apply NEC Article 310 derating factors based on ambient room temperatures and total enclosed conductor counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eUltra-Flexible Class I Tinned Copper Conductor:\u003c\/b\u003e Features approximately 163 individual strands of fully annealed tinned copper. This ultra-fine layout allows the 2 AWG cable to bend and flex easily around architectural corners without kinking, while the tin coating prevents copper corrosion and eases lug terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePremium EPR (Ethylene Propylene Rubber) Insulation:\u003c\/b\u003e Coated with a thick layer of high-dielectric EPR insulation. This thermoset compound handles extreme temperature swings without softening, cracking, or experiencing internal voltage tracking breakdowns under 2000V strains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eHeavy-Duty CPE (Chlorinated Polyethylene) Outer Jacket:\u003c\/b\u003e Protected by an industrial-grade, abrasion-resistant black CPE jacket. It provides excellent defense against grease, fuel oils, petrochemical solvents, ozone, severe impacts, and continuous open-air sunlight exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eMulti-Certified Safety Standard Ratings:\u003c\/b\u003e Dual-listed as Type RHH\/RHW-2 under UL 44, allowing code-compliant installation at 90 degrees C in both wet and dry applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eDiesel-Electric Locomotive Infrastructure:\u003c\/b\u003e Supplying auxiliary power links between central diesel generator blocks, dynamic braking grids, and auxiliary equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eOil and Gas Drilling Rigs:\u003c\/b\u003e Powering mud pumps, localized control enclosures, rotary tables, and marine drilling platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eData Centers \u0026amp; Battery Backup Banks:\u003c\/b\u003e Connecting high-capacity Uninterruptible Power Supply (UPS) networks, commercial energy storage arrays, and high-voltage backup battery setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eIndustrial Motor \u0026amp; Generator Leads:\u003c\/b\u003e Serving as flexible high-current feeder links on manufacturing motors, automated mining machinery, and mobile generator sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eTelecommunications Power Plants:\u003c\/b\u003e Providing localized low-voltage drop, high-amperage DC power distribution lines inside central switching hubs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCable Layer Architecture (From Core to Jacket)\u003c\/h4\u003e\n\u003col start=\"1\" data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCentral Conductor:\u003c\/b\u003e 2 AWG rope-lay, bunch-stranded tinned copper core (typically a 163\/24 configuration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eSeparator Layer:\u003c\/b\u003e Clear polyester or paper binding tape to prevent the fine copper strands from sticking to the insulation during high-heat stripping operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePrimary Insulation:\u003c\/b\u003e Premium-grade Ethylene Propylene Rubber (EPR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eOuter Protective Armor:\u003c\/b\u003e Rugged, thermoset, weather-proof Black Chlorinated Polyethylene (CPE) jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 2 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eConductor Stranding Count:\u003c\/b\u003e Approx. 163 Strands (24 AWG strand size)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Tinned Annealed Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e Ethylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e Chlorinated Polyethylene (CPE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eNominal Outer Diameter:\u003c\/b\u003e Approx. 0.57 to 0.61 inches (Varies slightly by manufacturer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eApproximate Net Weight:\u003c\/b\u003e Approx. 295 to 325 lbs per 1000 feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 2000 Volts Maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,8,0\"\u003e\u003cb data-path-to-node=\"15,8,0\" data-index-in-node=\"0\"\u003eMaximum Conductor Temperature:\u003c\/b\u003e 90 degrees C (Continuous wet or dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,9,0\"\u003e\u003cb data-path-to-node=\"15,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL Listed Type RHH\/RHW-2, CSA Type RW90\/RW90-TC (1kV), MSHA Approved (Mine Safety), ICEA S-95-658, NEMA WC-70, IEEE 1202\/FT4 Flame Test Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eTechnical Note Regarding Lugs:\u003c\/b\u003e Because 2 AWG DLO cable utilizes extra-fine Class I stranding, \u003cb data-path-to-node=\"17\" data-index-in-node=\"94\"\u003estandard mechanical compression lugs or standard building wire barrels cannot be used\u003c\/b\u003e. Attempting to force fine stranding into a standard building wire lug will shred the copper fibers and create a major fire hazard from loose connections. Installers must exclusively use specialty chamfered compression lugs specifically rated for \"Flexible Strand, Class I, or DLO Cable\" and secure them using calibrated crimping dies.\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 2 AWG Single-Conductor Flexible 2000V Diesel Locomotive Power Cable (Black CPE Jacket)\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Industrial high-voltage power networks and flexible cable trays must strictly comply with the National Electrical Code (NEC), local municipal safety enforcement mandates, and individual equipment installation datasheets. Always verify official product submittal listings and exact core metrics with your electrical component manufacturer prior to configuring terminal arrays or subjecting lines to high pulling forces.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981896253754,"sku":"DLO2-250","price":917.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981896286522,"sku":"DLO2-500","price":1823.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981896319290,"sku":"DLO2-1K","price":3627.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981896352058,"sku":"DLO2-FT","price":3.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/DLO_2_AWG_63c888b6-f857-40d9-93f0-e1695d916252.jpg?v=1760026650","url":"https:\/\/www.wireamerica.com\/products\/2-awg-diesel-locomotive-cable-2kv","provider":"Wire America ","version":"1.0","type":"link"}