{"product_id":"2-0-3c-w-ground-18-9c-aluminum-generator-cable-ul-type-tc-tc-er-jp","title":"Aluminum Generator Cable, 2\/0-3C w\/ Ground + 18\/9C, 135 Amps, 26kW-28kW, 600V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e2\/0 AWG 3-Conductor Aluminum Generator Cable with Ground and 18 AWG 9-Conductor Control Bundle\u003c\/b\u003e is a specialized, all-in-one power and intelligence composite cable engineered for standby home generators and light commercial backup systems. Designed to streamline complex multi-conduit runs into a single pulling operation, this dual-rated line is optimized to support \u003cb data-path-to-node=\"1\" data-index-in-node=\"367\"\u003e26kW to 28kW generator units\u003c\/b\u003e, supplying up to \u003cb data-path-to-node=\"1\" data-index-in-node=\"413\"\u003e135 Amps\u003c\/b\u003e of continuous emergency load capacity under a maximum 600V operating threshold.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThis heavy-duty hybrid asset combines raw electrical power distribution with low-voltage system logic inside a rugged, sunlight-resistant, direct-burial polyvinyl chloride (PVC) outer jacket. The power core features three robust 2\/0 AWG compact-stranded aluminum conductors accompanied by an insulated aluminum ground. Nestled alongside this main power run is a built-in 18 AWG 9-conductor control cable wiring harness, providing the necessary paths for automated utility sensing, battery charging, and generator command intelligence without requiring a separate layout pipe.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eELECTRICAL AMPACITY \u0026amp; GENERATOR RUN RATINGS\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eEngineered to match the high-demand continuous loads of automated emergency standby equipment, this composite cable features distinct power limits based on insulation parameters and structural cooling boundaries:\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMaximum Current Capacity (75°C Terminations): 135 AMPS\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003eThis rating complies with National Electrical Code (NEC) Article 310 parameters for Type THHN\/THWN-2 aluminum conductors terminated into standard 75°C equipment lugs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003ePower Output Handling Range: 26 kW to 28 kW\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003eOptimized explicitly for single-phase \u003cspan class=\"math-inline\" data-math=\"240\\text{V}\" data-index-in-node=\"82\"\u003e240V\u003c\/span\u003e residential generator applications, providing safe mechanical and thermal headroom during cold starts and sudden utility transfer load spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eAll-In-One Unified Design:\u003c\/b\u003e Combines heavy aluminum power conductors and a multi-conductor copper control bundle within a single outer jacket, slashing trench labor, minimizing conduit jam scenarios, and eliminating multiple pipe runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eCompact-Stranded AA-8000 Aluminum Alloy:\u003c\/b\u003e Power conductors are extruded using advanced AA-8000 series aluminum alloy, providing excellent flexibility, reduced cable weight, and highly reliable connections at standard equipment lugs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eIntegrated 18\/9C Copper Control Core:\u003c\/b\u003e Features a dedicated 9-conductor, 18 AWG copper signaling bundle that provides smooth transmission for automated automatic transfer switch (ATS) communication, smart digital monitoring, oil pressure sensors, and float chargers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eDual-Rated THHN \/ THWN-2 Elements:\u003c\/b\u003e Internal power lines are insulated with tough polyvinyl chloride (PVC) and topped with a slick nylon armor skin, rated for dry environments up to 90°C and wet subterranean environments up to 75°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eDirect-Burial Outer Armor Jacket:\u003c\/b\u003e Protected by an industrial-grade, sunlight-resistant, moisture-impervious PVC outer shield. This jacket allows the cable to be run inside standard PVC conduit, heavy metal raceways, or laid directly into open underground trenches where code permits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eAutomated Standby Generator Connections:\u003c\/b\u003e Linking 26kW through 28kW residential and light industrial generators safely to their respective Automatic Transfer Switches (ATS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eWhole-House Backup Infrastructure:\u003c\/b\u003e Running high-amperage backup links for estate homes, rural agricultural facilities, and critical municipal pump sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eMulti-Zone ATS Communication Paths:\u003c\/b\u003e Providing the unified power feed and remote-start signaling circuit between isolated generator docks and internal building sub-panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCable Component Architecture (Cross-Section)\u003c\/h4\u003e\n\u003col start=\"1\" data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eMain Power Elements:\u003c\/b\u003e 3 independent 2\/0 AWG compact-stranded aluminum conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eEquipment Ground:\u003c\/b\u003e 1 insulated matching aluminum ground wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eControl Bundle:\u003c\/b\u003e 9 independent 18 AWG solid or stranded copper control lines enclosed in an inner protective binder wrap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eOuter Jacket:\u003c\/b\u003e Rugged, moisture-proof, UV-resistant Black PVC outer skin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003ePower Conductor Size:\u003c\/b\u003e 2\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eNumber of Power Conductors:\u003c\/b\u003e 3 (Typically designated Black, Red, White for Single-Phase 120\/240V systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003ePower Conductor Material:\u003c\/b\u003e AA-8000 Series Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eGround Conductor Size:\u003c\/b\u003e Fully sized aluminum ground\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eControl Bundle Configuration:\u003c\/b\u003e 18 AWG \/ 9-Conductor (Copper)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts Maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eContinuous Current Capacity:\u003c\/b\u003e 135 Amps (Based on 75°C termination limits)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e PVC with Nylon Skin (THHN \/ THWN-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,8,0\"\u003e\u003cb data-path-to-node=\"15,8,0\" data-index-in-node=\"0\"\u003eJacket Type:\u003c\/b\u003e Polyvinyl Chloride (PVC) - Sunlight Resistant, Direct Burial Rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,9,0\"\u003e\u003cb data-path-to-node=\"15,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL Listed, NEC Article 310, NEC Article 445 (Generators), RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e To prevent localized oxidation and terminal failures over time, all aluminum-to-copper transitions or connections at the generator terminal blocks \u003cb data-path-to-node=\"17\" data-index-in-node=\"163\"\u003emust be coated with a certified anti-oxidant joint compound (such as Noalox or Penetrox)\u003c\/b\u003e. Tighten all mechanical terminal lugs strictly to the manufacturer's specified inch-pounds of torque using a calibrated torque wrench.\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 2\/0-3C Aluminum Power with Ground + 18 AWG 9-Conductor Copper Control Composite Generator Cable (600V Rated)\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Emergency standby generator systems and automatic utility transfer switches must strictly adhere to NFPA 70 (National Electrical Code), local utility company parameters, and the specific manufacturer’s wiring schematics. Always cross-reference the official engineering data sheet and local structural code books prior to pulling cable lengths or finalizing backup power hookups.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53649077698874,"sku":"GEN-ALTC9-2\/0-3-250","price":2355.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53649077731642,"sku":"GEN-ALTC9-2\/0-3-500","price":4685.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53649077764410,"sku":"GEN-ALTC9-2\/0-3-1K","price":9321.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53649077797178,"sku":"GEN-ALTC9-2\/0-3-FT","price":9.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/aluminum-generator-cable-2-0-3c-ground-18-9c.jpg?v=1782422554","url":"https:\/\/www.wireamerica.com\/products\/2-0-3c-w-ground-18-9c-aluminum-generator-cable-ul-type-tc-tc-er-jp","provider":"Wire America ","version":"1.0","type":"link"}