{"product_id":"2-0-3-conductor-direct-burial-aluminum-mc-cable","title":"2\/0-3C Direct Burial Aluminum MC Cable with Bare Ground (PVC Jacketed)","description":"\u003cp\u003e\u003cstrong\u003e\"Engineered for maximum power capacity and tough underground environments, 2\/0 3-Conductor Direct Burial Aluminum MC Cable delivers complete feeder protection without the added labor or expense of installing underground conduit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis heavy-duty cable features three 2\/0 AWG compact-stranded aluminum phase conductors and one #4 AWG aluminum ground conductor, protected by an interlocked aluminum armor and covered in a rugged, moisture-proof, UV-resistant PVC outer jacket. Fully approved per NEC Article 330 for direct earth burial, wet locations, and cable tray applications, it is the ultimate cost-effective solution for 135A to 150A service distribution, commercial subpanels, and agricultural power runs.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eKey Features \u0026amp; Benefits: 2\/0-3 Direct Burial MC Cable\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDirect Burial Approved (No Conduit Required):\u003c\/b\u003e The extruded PVC outer jacket isolates the interlocked aluminum armor from moisture, soil chemicals, and ground rot, allowing you to lay cable directly into open trenches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e3-Conductor High-Amp Layout:\u003c\/b\u003e Features three insulated 2\/0 AWG power legs plus a bare #4 ground—ideal for 3-phase 3-wire delta systems, service feeds, and heavy machinery runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCompact Stranded AA-8000 Aluminum:\u003c\/b\u003e Built with lightweight AA-8000 series aluminum alloy that reduces overall cable diameter, making it easier to pull through tight bends without sacrificing ampacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSuperior Mechanical Armor:\u003c\/b\u003e The flexible interlocked aluminum armor shields internal wires from soil shifts, sharp rocks, crushed backfill, and physical impacts during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSunlight \u0026amp; Flame Resistant:\u003c\/b\u003e Designed to handle direct exposure to sunlight, wet locations, and indoor\/outdoor transitions seamlessly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003eAluminum Interlocked Armor (AIA):\u003c\/b\u003e Continuous metal armor delivers crushing and impact defense, eliminating the material and labor costs of assembling separate conduit systems\u003c\/span\u003e\u003cspan\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003cspan\u003e\u003cb\u003eXHHW-2 XLPE Insulation:\u003c\/b\u003e Phase conductors are encased in cross-linked polyethylene insulation approved for 90°C wet and dry environments\u003c\/span\u003e\u003cspan\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003csup class=\"superscript\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/span\u003e \u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003cbr\u003e\u003cspan\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Specifications: 2\/0-2\/0-2\/0 Direct Burial Alum MC Cable +  #4 Ground\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-900\"\u003e\u003cspan\u003e\u003cb\u003eConductor Size:\u003c\/b\u003e 2\/0 \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-901\"\u003e\u003cspan\u003e\u003cb\u003eNumber of Power Conductors:\u003c\/b\u003e 3\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-902\"\u003e\u003cspan\u003e\u003cb\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Compact Stranded Aluminum Alloy\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-903\"\u003e\u003cspan\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e 4 AWG Bare Aluminum\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-904\"\u003e\u003cspan\u003e\u003cb\u003ePhase Colors (240V):\u003c\/b\u003e Black, White, Red \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-905\"\u003e\u003cspan\u003e\u003cb\u003eInsulation Type:\u003c\/b\u003e XLPE \/ XHHW-2\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-906\"\u003e\u003cspan\u003e\u003cb\u003eArmor Type:\u003c\/b\u003e AIA (Aluminum Interlocked Armor)\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-907\"\u003e\u003cspan\u003e\u003cb\u003eProtective Outer Jacket:\u003c\/b\u003e PVC - Black (Sunlight \u0026amp; Moisture Resistant)\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-908\"\u003e\u003cspan\u003e\u003cb\u003eVoltage Rating:\u003c\/b\u003e 600 Volts\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-909\"\u003e\u003cspan\u003e\u003cb\u003eTemperature Rating:\u003c\/b\u003e -40°C to 90°C\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-910\"\u003e\u003cspan\u003e\u003cb\u003eAmp Rating (@ 75°C - NEC):\u003c\/b\u003e 135 Amps\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-911\"\u003e\u003cspan\u003e\u003cb\u003eAmp Rating (@ 90°C - NEC):\u003c\/b\u003e 150 Amps\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-912\"\u003e\u003cspan\u003e\u003cb\u003eInsulation Thickness:\u003c\/b\u003e 0.055 inches\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-913\"\u003e\u003cspan\u003e\u003cb\u003eJacket Thickness:\u003c\/b\u003e 0.050 inches\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-914\"\u003e\u003cspan\u003e\u003cb\u003eApproximate Nominal Outer Diameter:\u003c\/b\u003e 1.52 inches\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-915\"\u003e\u003cspan\u003e\u003cb\u003eApproximate Net Weight:\u003c\/b\u003e 875 lbs per 1,000 ft\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eMinimum Bending Radius:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e10.64 inches\u003cspan\u003e \u003c\/span\u003e\u003ci\u003e(Calculated as 7x Diameter Over Jacket)\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-917\"\u003e\u003cspan\u003e\u003cb\u003eCompliance Standards:\u003c\/b\u003e UL 44, UL 1569 (Type MC), NEMA WC70 \/ ICEA S-95-658, IEEE 1202, ASTM B800 \u0026amp; B801, NEC 518.4, NEC 520.5, NEC 645.5, and NEC 300.22\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommon 2\/0-3 Alum MC Cable PVC Jacket Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-918\"\u003e\u003cspan\u003e\u003cb\u003eMain Feeders \u0026amp; Subpanels:\u003c\/b\u003e Supplying main power from utility disconnects to 125A–150A distribution panels, commercial subpanels, and outbuildings\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-919\"\u003e\u003cspan\u003e\u003cb\u003eIndustrial Facility Power:\u003c\/b\u003e Routing high-amperage lines across commercial facilities, manufacturing plants, and industrial job sites via cable trays or exposed runs\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_1046e5f4fee70192-920\"\u003e\u003cspan\u003e\u003cb\u003eUnderground Trench Distribution:\u003c\/b\u003e Laying direct-buried feeder lines between separate structures, workshops, pump houses, and agricultural facilities\u003c\/span\u003e\u003cspan\u003e\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp id=\"p-rc_02093c4c4f149f2c-513\"\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cb\u003eTechnical Note:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eTo prevent structural degradation from galvanic corrosion, installers must utilize dual-rated AL7CU or AL9CU mechanical compression lugs or mechanical split-bolts when joining this aluminum cable to copper busbars or breaker terminals. Penetrox or similar antioxidant joint compound must be thoroughly applied to all bare aluminum conductors before final structural torquing. While the PVC jacket isolates the interior armor against direct soil or chemical contact, minimum trench depth profiles must strictly comply with NEC Article 300.5 tables (typically requiring 24 inches of earth cover for direct-buried cables not under concrete paths, or 18 inches beneath standard structural landscapes).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDISCLAIMER:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eThe technical information provided is for general reference only. Large-scale high-voltage feeder systems and underground distribution paths must strictly adhere to the National Electrical Code (NEC), local electrical building enforcement, and relevant safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing structural configurations or executing structural cuts.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53532995486010,"sku":"MCA2\/0-3JKT-250","price":2266.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53532995518778,"sku":"MCA2\/0-3JKT-500","price":4508.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532995551546,"sku":"MCA2\/0-3JKT-1K","price":8970.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53532995584314,"sku":"MCA2\/0-3JKT-FT","price":9.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2-0-3c-aluminum-mc-cable-direct-burial-pvc-jacketed.jpg?v=1781014952","url":"https:\/\/www.wireamerica.com\/products\/2-0-3-conductor-direct-burial-aluminum-mc-cable","provider":"Wire America ","version":"1.0","type":"link"}