{"product_id":"18-4-nyc-approved-fire-alarm-cable-fplp-ll39-200c","title":"18\/4 Unshielded NYC Approved FPLP Fire Alarm Cable | 200°C LL39","description":"\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOur 18\/4 NYC Certified FPLP Plenum Rated Fire Alarm Cable\u003c\/strong\u003e is used for wiring fire alarms, smoke detectors, voice communications, burglar alarms, and approved for NYC LL39 (formerly LL5) fire protective circuits installed in the City of New York. Applications not to exceed 300 volts, suitable for use up to 200°C.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eFully annealed solid bare copper per ASTM B3 \u0026amp; B258.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003c\/strong\u003e\u003cbr\u003eInsulated conductors cabled together with or without shield under an overall jacket. Ripcord and sequential footage markings to facilitate installation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR COLORS:\u003c\/strong\u003e\u003cbr\u003ePair 1 - Black and Red\u003cbr\u003ePair 2 - Yellow and Green\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET COLOR:\u003c\/strong\u003e\u003cbr\u003eRed\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003ePremium-grade, color-coded FEP.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eWhy Professionals Choose 18\/4 FPLP Unshielded NYC Approved Cable:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eLL39 Compliance Guaranteed:\u003c\/b\u003e Specifically manufactured with the required NYC-certified print legend to ensure your project passes DOB electrical inspections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSpace-Saving 4-Conductor Design:\u003c\/b\u003e Allows for the installation of dual addressable loops or redundant signaling circuits in a single pull, maximizing conduit capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003e200°C FEP Construction:\u003c\/b\u003e Built with \u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"41\"\u003eFluorinated Ethylene Propylene (FEP)\u003c\/b\u003e insulation, offering extreme thermal survivability that standard 75°C or 105°C plenum wires cannot match.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eHigh-Flexibility 18 AWG:\u003c\/b\u003e The smaller gauge size makes this cable incredibly easy to navigate through tight bends and crowded junction boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003ePlenum Rated (FPLP):\u003c\/b\u003e UL-listed for air-handling spaces and high-rise plenums, eliminating the need for conduit in many interior applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eInstaller’s Note:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\"When you're dealing with crowded conduits in an NYC retrofit or a dense new build, the \u003cb data-path-to-node=\"9,0\" data-index-in-node=\"88\"\u003e18\/4 FPLP NYC Approved Fire Alarm\u003c\/b\u003e \u003cstrong\u003eCable\u003c\/strong\u003e is a lifesaver. It gives you four conductors of \u003cb data-path-to-node=\"9,0\" data-index-in-node=\"164\"\u003eLocal Law 39\u003c\/b\u003e compliant power and signal in a very slim profile. Because it uses a 200°C FEP jacket, you're not just saving space—you're installing a system that can withstand extreme thermal events without the insulation 'gumming up' or failing.\"\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction.\u003c\/em\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"500 ft. Spool","offer_id":52000182993210,"sku":"FAP-USHDNY18-2P-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000183025978,"sku":"FAP-USHDNY18-2P-1K","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/16-2P_Unshielded_Plenum_Fire_Alarm_Cable_NY_Certified_62f65b12-75e7-4586-9e07-ac328a621d32.jpg?v=1760026667","url":"https:\/\/www.wireamerica.com\/products\/18-4-nyc-approved-fire-alarm-cable-fplp-ll39-200c","provider":"Wire America ","version":"1.0","type":"link"}