{"product_id":"18-25-shielded-vntc-tray-cable-tffn-pvc","title":"18-25 Shielded VNTC Tray Cable, TFFN\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"1\"\u003eThis 18 AWG, 25-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a high-density, dual-rated Type TC-ER industrial cable. It is engineered for large-scale control systems and instrumentation signaling where significant electromagnetic interference (EMI) protection is required. The TC-ER (Exposed Run) rating provides maximum installation flexibility, allowing the cable to transition from a tray to equipment without the need for conduit.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18-25 Shielded VNTC (TC-ER)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eExposed Run (TC-ER) Rated:\u003c\/b\u003e This cable has passed the rigorous UL 1277 crush and impact tests. Per NEC 336.10, it can extend from the cable tray to the equipment for up to 6 feet without continuous support or conduit, drastically lowering labor and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003e100% EMI\/RFI Shielding:\u003c\/b\u003e The overall aluminum foil-polyester tape shield and tinned copper drain wire ensure signal integrity by blocking electrical noise from surrounding power leads and high-frequency machinery across all 25 conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eFlexible TFFN Conductors:\u003c\/b\u003e Utilizing TFFN (Thermoplastic Flexible Fixture Nylon) stranded conductors makes this high-conductor-count cable significantly easier to manipulate, strip, and terminate in tight control panels compared to standard THHN.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eIndustrial Durability:\u003c\/b\u003e Featuring a flame-retardant, sunlight-resistant PVC jacket, this cable is resistant to moisture, heat, and oils. It is approved for direct burial and use in Class I, Division 2 hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eCentralized Process Control:\u003c\/b\u003e Connecting main PLC cabinets to massive arrays of field sensors, solenoids, and actuators in a single shielded run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003ePower Plant \u0026amp; Utility Signaling:\u003c\/b\u003e Managing comprehensive telemetry, status signaling, and control logic in high-interference environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eRefinery \u0026amp; Chemical Processing:\u003c\/b\u003e Durable enough for the chemical and moisture-heavy environments found in treatment plant raceways and trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eAutomated Assembly Lines:\u003c\/b\u003e Bundling multiple control signals into one organized run for large robotic cells and complex manufacturing equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: E2 Color Code\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe conductors are identified using the industry-standard E2 color sequence (Black, Red, Blue, Orange, Yellow, Brown, then repeated with various stripes).\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eNumber of Conductors:\u003c\/b\u003e 25\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eInsulation:\u003c\/b\u003e TFFN (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eRatings:\u003c\/b\u003e 600V | 90°C Dry | \u003cb data-index-in-node=\"27\" data-path-to-node=\"9,7,0\"\u003eType TC-ER\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eCompliance:\u003c\/b\u003e UL 1277, UL 66, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Note:\u003c\/b\u003e To ensure the shield functions as intended, the tinned copper drain wire should be properly terminated to a ground bus at the source end only. This prevents ground loops while allowing the shield to effectively drain induced interference. Because this cable has 25 conductors, ensure that your tray system or conduit fill calculations account for its specific weight and outside diameter.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eCABLE TYPE:\u003c\/b\u003e 18\/25 Shielded VNTC (TFFN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"43\" data-path-to-node=\"12\"\u003eRATING:\u003c\/b\u003e Type TC-ER\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"62\" data-path-to-node=\"12\"\u003eCOLOR CODE:\u003c\/b\u003e E2 Standard\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53433211814202,"sku":"TCTFFN18-25SH-250","price":1178.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53433211846970,"sku":"TCTFFN18-25SH-500","price":2343.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53433211879738,"sku":"TCTFFN18-25SH-1K","price":4661.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53433211912506,"sku":"TCTFFN18-25SH-FT","price":4.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-25-shielded-vntc-tray-cable-tffn-pvc-tc-er-25-core.jpg?v=1778528900","url":"https:\/\/www.wireamerica.com\/products\/18-25-shielded-vntc-tray-cable-tffn-pvc","provider":"Wire America ","version":"1.0","type":"link"}