{"product_id":"18-12-unshielded-substation-control-cable-15-10-pe-pvc","title":"18\/12 Unshielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 18 AWG, 12-conductor unshielded substation control cable is a multi-circuit cable engineered for utility and industrial environments requiring precise signal and lower-current control mapping. Built to strict ICEA standards, it features a specialized composite 15\/10 PE\/PVC insulation system designed for smaller gauge profiles. Because it is unshielded, it is optimized for multi-point secondary control loops and dense terminal cabinet routing where high-frequency electromagnetic interference (EMI) shielding is not required, offering excellent flexibility and an easy termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/12 Unshielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eSpecialized 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 15 mils of Natural Polyethylene (PE) for dependable dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape or braided shield, this multi-conductor cable features an exceptionally small overall outer diameter and tight bending radius, making it incredibly easy to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHighly Flexible Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing durable service life with high flexibility for tight terminal block terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSecondary Control Circuits:\u003c\/b\u003e Consolidating lower-current monitoring, signaling, and control circuits from auxiliary panels, annunciators, and status indicator lights to main switchgear blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Control Panels:\u003c\/b\u003e Routing interlocking control networks, remote circuit breaker position indicators, and auxiliary alarm lines within the substation control house.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for low-current solenoid controls, status relays, and automated sequencing arrays where multiple discrete voltage pathways must span long physical distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Automation \u0026amp; Control:\u003c\/b\u003e General-purpose multi-conductor control loops and machinery automation links in power generation stations, wastewater treatment facilities, and industrial manufacturing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_dcb089f23fdd7943-342\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Note that this cable utilizes a \u003cb data-path-to-node=\"11\" data-index-in-node=\"48\"\u003e15\/10 insulation profile\u003c\/b\u003e (25 mils total) rather than the 20\/10 profile common in heavier 14 AWG to 10 AWG substation cables, reflecting its smaller 18 AWG conductor base. Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"239\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 12-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488712614202,"sku":"SUB18-12-15\/10-250","price":313.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488712646970,"sku":"SUB18-12-15\/10-500","price":623.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488712679738,"sku":"SUB18-12-15\/10-1K","price":1239.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488712712506,"sku":"SUB18-12-15\/10-FT","price":1.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-12-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887776","url":"https:\/\/www.wireamerica.com\/products\/18-12-unshielded-substation-control-cable-15-10-pe-pvc","provider":"Wire America","version":"1.0","type":"link"}