{"product_id":"16-9-shielded-vntc-tray-cable-tffn-pvc","title":"16-9 Shielded VNTC Tray Cable, TFFN\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"1\"\u003eThis 16 AWG, 9-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a high-performance, dual-rated Type TC-ER industrial cable. Built for multi-circuit control and instrumentation, it features a 16 AWG conductor gauge for higher current capacity and 100% foil shielding to maintain signal integrity. The TC-ER (Exposed Run) rating provides significant installation flexibility by allowing the cable to transition from a tray to equipment without the need for conduit.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 16-9 Shielded VNTC (TC-ER)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eExposed Run (TC-ER) Rated:\u003c\/b\u003e This cable meets the rigorous crush and impact standards of UL 1277. Per NEC 336.10, it can be routed outside of a cable tray to the equipment it connects for up to 6 feet without continuous support or conduit, lowering labor costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003e100% EMI\/RFI Shielding:\u003c\/b\u003e Equipped with an overall aluminum foil-polyester tape shield and a tinned copper drain wire. This construction ensures total coverage, preventing electromagnetic interference from surrounding motor leads and high-frequency machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eEnhanced Conductor Capacity:\u003c\/b\u003e The 16 AWG gauge provides lower resistance and higher current-carrying capacity than 18 AWG, making it ideal for longer circuit runs where voltage drop might be a concern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eFlexible TFFN Conductors:\u003c\/b\u003e Utilizing TFFN (Thermoplastic Flexible Fixture Nylon) stranded conductors ensures the cable remains manageable during installation, making it easier to pull through trays and terminate in crowded control enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eMulti-Point Control Logic:\u003c\/b\u003e Connecting PLC cabinets to machinery requiring several control points, such as sensor arrays, solenoids, and motor starters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eIndustrial Automation:\u003c\/b\u003e Ideal for robotic cells and automated assembly lines where conductors must drop from overhead trays directly to machine-mounted junction boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eUtility \u0026amp; Power Monitoring:\u003c\/b\u003e Managing telemetry, status signaling, and control logic in power plants and substations where electrical noise is constant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eProcess Instrumentation:\u003c\/b\u003e Suitable for multi-point feedback and sensor monitoring in refineries, chemical plants, and water treatment facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: E2 Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003e2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003e3:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003e4:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,4,0\"\u003e5:\u003c\/b\u003e Yellow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,5,0\"\u003e6:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,6,0\"\u003e7:\u003c\/b\u003e Red with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,7,0\"\u003e8:\u003c\/b\u003e Blue with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,8,0\"\u003e9:\u003c\/b\u003e Orange with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eConductor Size:\u003c\/b\u003e 16 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eNumber of Conductors:\u003c\/b\u003e 9\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eInsulation:\u003c\/b\u003e TFFN (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eRatings:\u003c\/b\u003e 600V | 90°C Dry | \u003cb data-index-in-node=\"27\" data-path-to-node=\"9,7,0\"\u003eType TC-ER\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eCompliance:\u003c\/b\u003e UL 1277, UL 66, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Note:\u003c\/b\u003e To maximize the effectiveness of the shield, the tinned copper drain wire should be landed at a ground bus at the source end only. This configuration prevents ground loops. Given the 9-conductor 16 AWG construction, ensure that tray load and conduit fill calculations are verified prior to installation due to the cable's specific diameter and weight.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eCABLE TYPE:\u003c\/b\u003e 16\/9 Shielded VNTC (TFFN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"42\" data-path-to-node=\"12\"\u003eRATING:\u003c\/b\u003e Type TC-ER\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"61\" data-path-to-node=\"12\"\u003eCOLOR CODE:\u003c\/b\u003e E2 Standard\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53433214370106,"sku":"TCTFFN16-9SH-250","price":195.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53433214402874,"sku":"TCTFFN16-9SH-500","price":388.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53433214435642,"sku":"TCTFFN16-9SH-1K","price":771.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53433214468410,"sku":"TCTFFN16-9SH-2500","price":1916.0,"currency_code":"USD","in_stock":true},{"title":"5000 ft. Spool","offer_id":53433214501178,"sku":"TCTFFN16-9SH-5K","price":3812.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53433214533946,"sku":"TCTFFN16-9SH-FT","price":0.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/16-9-shielded-vntc-tray-cable-tffn-pvc-tc-er-control.jpg?v=1778521140","url":"https:\/\/www.wireamerica.com\/products\/16-9-shielded-vntc-tray-cable-tffn-pvc","provider":"Wire America ","version":"1.0","type":"link"}