{"product_id":"14-3-shielded-vntc-tray-cable-thhn-pvc","title":"14-3 Shielded VNTC Tray Cable Type TC-ER, THHN PVC 600V (Black, Red, Blue)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 3-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a dual-rated Type TC-ER industrial cable, designed for power and control applications requiring superior protection against electromagnetic interference (EMI). Featuring the standard Black, Red, and Blue color code, it is the industry choice for 3-phase circuits or 208\/240V systems requiring a shielded ground or neutral in electrically noisy environments.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14-3 Shielded VNTC (TC-ER)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eExposed Run (TC-ER) Rated:\u003c\/b\u003e This cable has passed the stringent UL 1277 crush and impact tests. Per NEC 336.10, it can extend from the cable tray to the equipment for up to 6 feet without continuous support or conduit, significantly reducing labor and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e100% EMI\/RFI Shielding:\u003c\/b\u003e The overall aluminum foil-polyester tape shield, combined with a tinned copper drain wire, provides a total barrier against electrical noise, preventing signal disruption to nearby sensitive electronics and instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eStandard Industrial Color Code:\u003c\/b\u003e The Black, Red, and Blue conductors allow for easy identification in 3-phase motor applications or multi-wire branch circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eRuggedized Construction:\u003c\/b\u003e Featuring THHN\/THWN-2 conductors and a flame-retardant, sunlight-resistant PVC jacket, this cable is resistant to moisture, heat, and oils. It is approved for direct burial and use in Class I, Division 2 hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSmall 3-Phase Motors:\u003c\/b\u003e Perfect for powering and grounding small motors where a shield is necessary to prevent crosstalk with nearby control or data cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003ePrecision Control Loops:\u003c\/b\u003e Used for 120V control circuits where signal accuracy is critical, such as in telemetry or high-end industrial instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eVFD Peripheral Control:\u003c\/b\u003e Serving as a shielded control feed for auxiliary components associated with Variable Frequency Drives (VFDs) to contain high-frequency noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eAutomated Process Control:\u003c\/b\u003e Ideal for heavy-duty sensors and actuators in refineries, water treatment plants, and manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Standard Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e THHN\/THWN-2 (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eRatings:\u003c\/b\u003e 600V | 90°C Dry \/ 75°C Wet | \u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"38\"\u003eType TC-ER\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e UL 1277, UL 1581, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e To ensure the shield functions as intended, the tinned copper drain wire should be properly terminated to a ground bus at the source end only. This prevents ground loops while allowing the shield to drain induced interference. When utilizing the TC-ER rating for exposed runs, ensure the cable is secured and protected from physical damage in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14\/3 Shielded VNTC (THHN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"42\"\u003eRATING:\u003c\/b\u003e Type TC-ER \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information, ampacity ratings, and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53411988767034,"sku":"TCTHN14-3SH-250","price":217.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53411988799802,"sku":"TCTHN14-3SH-500","price":432.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53411988832570,"sku":"TCTHN14-3SH-1K","price":858.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53411988865338,"sku":"TCTHN14-3SH-2500","price":2134.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53411988898106,"sku":"TCTHN14-3SH-FT","price":0.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-3-black-red-blue-shielded-vntc-tray-cable-thhn-pvc.jpg?v=1778347845","url":"https:\/\/www.wireamerica.com\/products\/14-3-shielded-vntc-tray-cable-thhn-pvc","provider":"Wire America ","version":"1.0","type":"link"}