{"product_id":"14-3-shielded-vntc-tray-cable-thhn-pvc-tc-er","title":"14-3 Shielded VNTC Tray Cable Type TC-ER, THHN PVC 600V (Black\/White\/Red)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 3-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a dual-rated Type TC-ER industrial cable designed for power and control applications requiring maximum protection against electromagnetic interference (EMI). This specific configuration features the Black, White, and Red color code, making it ideal for 120\/240V single-phase circuits with a hot, neutral, and ground, or specialized control loops requiring high-visibility conductor identification.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14-3 Shielded VNTC (TC-ER)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eExposed Run (TC-ER) Rated:\u003c\/b\u003e This cable has passed the rigorous UL 1277 crush and impact tests. Per NEC 336.10, it can be installed between a cable tray and the equipment it connects for distances up to 6 feet without continuous support or conduit, significantly lowering installation costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003e100% EMI\/RFI Shielding:\u003c\/b\u003e The overall aluminum foil-polyester tape shield, backed by a tinned copper drain wire, provides a complete barrier against electrical noise, protecting sensitive digital and analog signals from surrounding high-voltage equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eVersatile Color Coding:\u003c\/b\u003e The Black, White, and Red conductor scheme is a standard choice for specific power applications, providing clear distinction for hot and neutral leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eRuggedized Construction:\u003c\/b\u003e Featuring THHN\/THWN-2 conductors and a flame-retardant, sunlight-resistant PVC jacket, this cable is resistant to moisture, heat, and oils. It is approved for direct burial and use in Class I, Division 2 hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e120V\/240V Control Power:\u003c\/b\u003e Ideal for providing shielded power to control cabinets, small motors, or actuators requiring a neutral connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSensitive Instrumentation:\u003c\/b\u003e Connecting PLCs to field devices where signal accuracy is paramount and EMI protection is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eIndustrial Automation:\u003c\/b\u003e Used in robotic cells and automated assembly lines where the cable must transition from a tray directly to a device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eVariable Frequency Drive (VFD) Accessories:\u003c\/b\u003e Serving as a shielded control feed for auxiliary components associated with VFD systems to contain electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Custom Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e THHN\/THWN-2 (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eRatings:\u003c\/b\u003e 600V | 90°C Dry \/ 75°C Wet | \u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"38\"\u003eType TC-ER\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e UL 1277, UL 1581, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e To ensure the shield functions correctly, the tinned copper drain wire must be properly terminated to a ground bus at the source end. This prevents ground loops while allowing the shield to effectively drain induced interference. When utilizing the TC-ER rating for exposed runs, ensure the cable is secured and protected from physical damage in accordance with NEC requirements.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14\/3 Shielded VNTC (THHN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"42\"\u003eRATING:\u003c\/b\u003e Type TC-ER \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information, ampacity ratings, and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53411988603194,"sku":"TCTHN14E1-3SH-250","price":217.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53411988635962,"sku":"TCTHN14E1-3SH-500","price":432.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53411988668730,"sku":"TCTHN14E1-3SH-1K","price":858.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53411988701498,"sku":"TCTHN14E1-3SH-2500","price":2134.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53411988734266,"sku":"TCTHN14E1-3SH-FT","price":0.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-3-black-white-red-shielded-vntc-tray-cable-thhn-pvc.jpg?v=1778348025","url":"https:\/\/www.wireamerica.com\/products\/14-3-shielded-vntc-tray-cable-thhn-pvc-tc-er","provider":"Wire America ","version":"1.0","type":"link"}