{"product_id":"14-25-tray-cable-thhn-pvc-vntc","title":"14\/25 VNTC Tray Cable Type TC-ER (THHN PVC 600V)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e14 AWG 25-Conductor VNTC (Vinyl Nylon Tray Cable) is a high-density industrial control, signaling, and power distribution cable engineered for installation in commercial wireways, open cable trays, and structural conduits. Featuring twenty-five 14 AWG conductors twisted into a dense, nested round core, this multi-conductor cable utilizes high-performance THHN\/THWN-2 inner conductor insulation wrapped in a rugged, sunlight-resistant Polyvinyl Chloride (PVC) outer jacket. This configuration provides a high-capacity, moisture-resistant wiring system optimized for routing complex control bundles, automated logic circuits, multi-point sensor networks, and multi-circuit utility feeds through demanding overhead or underground raceways.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eAMPACITY RATINGS (NEC 310.16)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003e60°C Terminal Rating: 15 AMPS\u003c\/b\u003e This is the baseline engineering safety rating. Use this value for final circuit sizing under normal operating conditions when connecting to standard equipment terminals or legacy breaker lugs restricted to 60°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003e75°C Terminal Rating: 20 AMPS\u003c\/b\u003e This is the standard engineering design rating. Use this value for modern industrial terminal configurations, as it represents the typical maximum operational ampacity for a 14 AWG copper conductor under normal code constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003e90°C Terminal Rating: 25 AMPS\u003c\/b\u003e This is the maximum capacity rating. Use this value strictly as the baseline calculation factor when adjusting or derating for high ambient operating temperatures, or when bundling multiple tray cables together in packed industrial raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eIndustrial Round Profile Construction:\u003c\/b\u003e The twisted-conductor architecture maximizes physical roundness and structural symmetry, providing uniform physical strength, balanced weight distribution, and effortless pull-ins through long conduit layouts or multi-bend raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDual THHN \/ THWN-2 Conductor Insulation:\u003c\/b\u003e Inner copper conductors are wrapped in high-dielectric PVC and topped with a rugged clear nylon skin. This dual-layer architecture ensures superior resistance to oil, gasoline, moisture, and insulation scraping during difficult installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Sunlight Resistant:\u003c\/b\u003e Protected by an extruded, flame-retardant outer PVC jacket that forms an impermeable barrier against harsh ambient conditions, making it safe for open air tray runs, direct direct-burial trenching, or wet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eHighly Conductive Bare Copper:\u003c\/b\u003e Manufactured with high-purity, soft-annealed stranded bare copper conductors to deliver optimal electrical conductivity, minimal line resistance, and sufficient physical flexibility for long pulled runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eRigorous Industrial Flame Ratings:\u003c\/b\u003e Engineered to prevent the migration of fire across open structural paths, fully certified to pass the demanding IEEE 1202 \/ UL 1685 vertical tray flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eIndustrial Control \u0026amp; Signaling:\u003c\/b\u003e Routing digital command inputs, massive multi-point PLC loops, multi-stage relay logic tracks, and automated sensor returns in manufacturing plants, wastewater treatment zones, and assembly environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eLighting \u0026amp; Power Control Networks:\u003c\/b\u003e Supplying continuous power to complex automation lines, multi-wire branches requiring numerous dedicated indicator and control lines, emergency lighting pathways, and industrial machinery sub-circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConduit and Wireway Routing:\u003c\/b\u003e Pulling high-density multi-circuit infrastructure connections through structural conduits, commercial utility tunnels, underground duct banks, or open-air wire mesh trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eHazardous Environment Deployment:\u003c\/b\u003e Approved under strict National Electrical Code provisions for installation within Class I, Division 2 hazardous industrial locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCircuit Identification: Standard 25-Conductor Phasing (ICEA Method 1, Table E-2)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor 4:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eConductor 5:\u003c\/b\u003e Yellow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eConductor 6:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eConductor 7:\u003c\/b\u003e Red with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eConductor 8:\u003c\/b\u003e Blue with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eConductor 9:\u003c\/b\u003e Orange with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eConductor 10:\u003c\/b\u003e Yellow with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eConductor 11:\u003c\/b\u003e Brown with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,11,0\"\u003e\u003cb data-path-to-node=\"11,11,0\" data-index-in-node=\"0\"\u003eConductor 12:\u003c\/b\u003e Black with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,12,0\"\u003e\u003cb data-path-to-node=\"11,12,0\" data-index-in-node=\"0\"\u003eConductor 13:\u003c\/b\u003e Blue with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,13,0\"\u003e\u003cb data-path-to-node=\"11,13,0\" data-index-in-node=\"0\"\u003eConductor 14:\u003c\/b\u003e Orange with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,14,0\"\u003e\u003cb data-path-to-node=\"11,14,0\" data-index-in-node=\"0\"\u003eConductor 15:\u003c\/b\u003e Yellow with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,15,0\"\u003e\u003cb data-path-to-node=\"11,15,0\" data-index-in-node=\"0\"\u003eConductor 16:\u003c\/b\u003e Brown with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,16,0\"\u003e\u003cb data-path-to-node=\"11,16,0\" data-index-in-node=\"0\"\u003eConductor 17:\u003c\/b\u003e Black with Blue Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,17,0\"\u003e\u003cb data-path-to-node=\"11,17,0\" data-index-in-node=\"0\"\u003eConductor 18:\u003c\/b\u003e Red with Blue Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,18,0\"\u003e\u003cb data-path-to-node=\"11,18,0\" data-index-in-node=\"0\"\u003eConductor 19:\u003c\/b\u003e Blue with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,19,0\"\u003e\u003cb data-path-to-node=\"11,19,0\" data-index-in-node=\"0\"\u003eConductor 20:\u003c\/b\u003e Orange with Blue Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,20,0\"\u003e\u003cb data-path-to-node=\"11,20,0\" data-index-in-node=\"0\"\u003eConductor 21:\u003c\/b\u003e Yellow with Blue Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,21,0\"\u003e\u003cb data-path-to-node=\"11,21,0\" data-index-in-node=\"0\"\u003eConductor 22:\u003c\/b\u003e Brown with Blue Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,22,0\"\u003e\u003cb data-path-to-node=\"11,22,0\" data-index-in-node=\"0\"\u003eConductor 23:\u003c\/b\u003e Black with Orange Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,23,0\"\u003e\u003cb data-path-to-node=\"11,23,0\" data-index-in-node=\"0\"\u003eConductor 24:\u003c\/b\u003e Red with Orange Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,24,0\"\u003e\u003cb data-path-to-node=\"11,24,0\" data-index-in-node=\"0\"\u003eConductor 25:\u003c\/b\u003e Blue with Orange Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,25,0\"\u003e\u003ci data-path-to-node=\"11,25,0\" data-index-in-node=\"0\"\u003eNote: Depending on the specific manufacturer, 25-conductor control configurations may alternatively be provided with uniform black insulation featuring high-visibility, continuous alphanumeric numbers (1-25).\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eNumber of Power Conductors:\u003c\/b\u003e 25\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PVC with Nylon Skin (THHN\/THWN-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,5,0\"\u003e\u003cb data-path-to-node=\"13,5,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,6,0\"\u003e\u003cb data-path-to-node=\"13,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,7,0\"\u003e\u003cb data-path-to-node=\"13,7,0\" data-index-in-node=\"0\"\u003eMaximum Temperature Rating:\u003c\/b\u003e 90°C Dry \/ 90°C Wet Continuous Operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,8,0\"\u003e\u003cb data-path-to-node=\"13,8,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e IEEE 1202, UL 1685 Vertical Tray Flame Test, FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,9,0\"\u003e\u003cb data-path-to-node=\"13,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 1277 (Type TC), NEC Article 336, Type THHN\/THWN-2 Conductors, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When engineering layouts with high-density multi-conductor tray cables like the 14-25 VNTC, installers must apply severe \u003cb data-path-to-node=\"15\" data-index-in-node=\"137\"\u003eampacity adjustment factors for more than three current-carrying conductors\u003c\/b\u003e per NEC Article 310.15(C)(1). For a 25-conductor cable where all lines carry continuous current, the ampacity must be derated down to \u003cb data-path-to-node=\"15\" data-index-in-node=\"347\"\u003e40%\u003c\/b\u003e of its baseline rating. Using the 90°C baseline calculation factor (25 Amps), the adjusted ampacity calculation drops to \u003cb data-path-to-node=\"15\" data-index-in-node=\"472\"\u003e10.0 Amps\u003c\/b\u003e. This significant derating factor must be carefully calculated against the total load profile of each circuit loop to prevent code violations, excessive thermal build-up inside the cable core, or premature breakdown of the insulation.\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14 AWG \/ 25-Conductor Stranded Round THHN\/PVC Type TC Tray Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Large-scale industrial power distribution paths, tray layouts, and machinery connections must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant industrial safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing physical system designs or cutting structural cable lengths.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52577020346682,"sku":"TCTHN14-25-250","price":1778.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52577020379450,"sku":"TCTHN14-25-500","price":3538.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52577020412218,"sku":"TCTHN14-25-1K","price":7040.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52577020444986,"sku":"TCTHN14-25-2500","price":17509.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52577020477754,"sku":"TCTHN14-25-FT","price":7.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Tray_Cable_THHN_PVC_19C_b1713fe4-0049-479e-bc95-e6207520f204.jpg?v=1763585259","url":"https:\/\/www.wireamerica.com\/products\/14-25-tray-cable-thhn-pvc-vntc","provider":"Wire America ","version":"1.0","type":"link"}