{"product_id":"14-2-shielded-vntc-tray-cable-thhn-pvc-black-white","title":"14-2 Shielded VNTC Tray Cable Type TC-ER, THHN PVC 600V (Black, White)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 2-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a high-performance industrial cable designed for control and power applications requiring robust protection against electromagnetic interference (EMI). Featuring a 100% foil shield and stranded copper conductors, it is ideal for circuits that must maintain signal integrity in electrically noisy environments.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14-2 Shielded VNTC\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eTotal Signal Integrity:\u003c\/b\u003e The overall aluminum foil-polyester tape shield provides 100% coverage, paired with a tinned copper drain wire to effectively ground out EMI and RFI from surrounding equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eRugged Conductor Insulation:\u003c\/b\u003e Utilizing THHN\/THWN-2 conductors with a PVC base and a tough nylon skin, the cable is resistant to abrasion, chemicals, and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eEnvironmental Resistance:\u003c\/b\u003e The outer PVC jacket is sunlight-resistant and flame-retardant, making it suitable for industrial cable trays and raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eIndustrial Compliance:\u003c\/b\u003e Rated for 600V and 90°C (dry), this cable is approved for use in Class I, Division 2 hazardous locations per NEC guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eIndustrial Control Loops:\u003c\/b\u003e Ideal for 24V or 120V control signals between PLC cabinets and field devices where noise suppression is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eInstrumentation \u0026amp; Telemetry:\u003c\/b\u003e Used to transmit sensitive data signals in power plants, refineries, and manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eSmall Equipment Power:\u003c\/b\u003e Providing shielded power to fans, actuators, or solenoids that are positioned near sensitive electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eRemote Signaling:\u003c\/b\u003e Effective for long-distance signaling where the shield prevents the \"antenna effect\" of picking up stray electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: Standard Power Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e THHN\/THWN-2 (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C Dry \/ 75°C Wet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e UL 1277 (Type TC), UL 1581, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e As a standard \u003cb data-path-to-node=\"11\" data-index-in-node=\"30\"\u003eType TC\u003c\/b\u003e cable, this product is designed for installation in cable trays, conduits, or raceways. It does \u003cb data-path-to-node=\"11\" data-index-in-node=\"134\"\u003enot\u003c\/b\u003e carry the TC-ER (Exposed Run) rating, meaning it generally requires continuous support or raceway protection and cannot be run as an \"exposed\" cable between the tray and equipment without conduit. To ensure the shield works properly, terminate the drain wire to a clean ground at the source end only to avoid ground loops.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14\/2 Shielded VNTC (THHN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"42\"\u003eRATING:\u003c\/b\u003e Type TC (Not TC-ER) \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information, ampacity ratings, and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53411988439354,"sku":"TCTHN14E1-2SH-250","price":175.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53411988472122,"sku":"TCTHN14E1-2SH-500","price":348.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53411988504890,"sku":"TCTHN14E1-2SH-1K","price":693.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53411988537658,"sku":"TCTHN14E1-2SH-2500","price":1722.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53411988570426,"sku":"TCTHN14E1-2SH-FT","price":0.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-2C-shielded-vntc-tray-cable-thhn-pvc-drain-wire.jpg?v=1778347729","url":"https:\/\/www.wireamerica.com\/products\/14-2-shielded-vntc-tray-cable-thhn-pvc-black-white","provider":"Wire America ","version":"1.0","type":"link"}