{"product_id":"12-37-shielded-vntc-tray-cable-thhn-pvc","title":"12-37 Shielded VNTC Tray Cable Type TC-ER (THHN PVC 600V)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 37-conductor shielded VNTC (Vinyl Nylon Tray Cable) is a high-density, dual-rated Type TC-ER industrial cable. It is engineered for complex instrumentation and multi-point signaling applications where significant electromagnetic interference (EMI) protection is required. The TC-ER (Exposed Run) rating allows the cable to transition from tray to equipment without the need for conduit.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12-37 Shielded VNTC (TC-ER)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eExposed Run (TC-ER) Rated:\u003c\/b\u003e This cable meets the stringent UL 1277 crush and impact requirements. Per NEC 336.10, it can be routed between a cable tray and equipment for distances up to 6 feet without continuous support or conduit, simplifying installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eHigh-Density Signal Consolidation:\u003c\/b\u003e Consolidates 37 individual control loops into a single jacket, drastically reducing installation labor and organizing complex control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003e100% EMI\/RFI Shielding:\u003c\/b\u003e The overall aluminum foil-polyester tape shield and tinned copper drain wire ensure signal integrity by blocking noise from high-voltage motor leads and power lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eRugged Construction:\u003c\/b\u003e Stranded 12 AWG copper conductors provide high ampacity and low resistance. The THHN\/THWN-2 insulation and flame-retardant PVC jacket offer resistance to moisture, oils, and chemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCentralized Control Centers:\u003c\/b\u003e Connecting main PLC cabinets to large motor control centers (MCCs) and massive terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003ePower Generation Facilities:\u003c\/b\u003e Comprehensive monitoring and status signaling for turbine, boiler, and generator systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003ePetrochemical \u0026amp; Refinery Automation:\u003c\/b\u003e Multi-point telemetry and valve control systems in harsh, hazardous environments (Class I, Division 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Robotics:\u003c\/b\u003e Bundling feedback and control signals for large-scale automated manufacturing cells where multiple sensors must be monitored.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 37\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Annealed Copper (Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e THHN\/THWN-2 (PVC with Nylon Skin)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e Overall Aluminum Foil-Polyester Tape (100% coverage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eDrain Wire:\u003c\/b\u003e Tinned Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Sunlight-Resistant PVC (Black)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eRatings:\u003c\/b\u003e 600V | 90°C Dry \/ 75°C Wet | \u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"38\"\u003eType TC-ER\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance:\u003c\/b\u003e UL 1277, UL 1581, IEEE 1202, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Due to the 37-conductor count, this cable has a significant diameter and weight. Verify that tray support structures and conduit fill ratios (if used) are sufficient. To effectively drain induced interference, land the tinned copper drain wire at the source end only to prevent ground loops.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12\/37 Shielded VNTC (THHN\/PVC)\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"43\"\u003eRATING:\u003c\/b\u003e Type TC-ER\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"62\"\u003eCOLOR CODE:\u003c\/b\u003e E2 Standard\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information, ampacity ratings, and color codes provided are for general reference only. Specifications may vary by manufacturer and are subject to change without notice. Always consult with a licensed electrical engineer or local building authorities to ensure compliance with the National Electrical Code (NEC) and all local safety regulations before installation.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53411994435898,"sku":"TCTHN12-37SH-250","price":4246.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53411994468666,"sku":"TCTHN12-37SH-500","price":8448.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53411994501434,"sku":"TCTHN12-37SH-1K","price":16809.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53411994534202,"sku":"TCTHN12-37SH-2500","price":41807.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53411994566970,"sku":"TCTHN12-37SH-FT","price":17.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-37-shielded-vntc-tray-cable-thhn-pvc-tc-er-37-conductor.jpg?v=1778349395","url":"https:\/\/www.wireamerica.com\/products\/12-37-shielded-vntc-tray-cable-thhn-pvc","provider":"Wire America ","version":"1.0","type":"link"}