{"product_id":"12-2-tray-cable-thhn-pvc-vntc","title":"12\/2 Flat VNTC Tray Cable Type (THHN PVC 600V)","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003e12 AWG 2-Conductor Flat VNTC (Vinyl Nylon Tray Cable) without Ground (Black\/Red Conductors)\u003c\/b\u003e is a specialized commercial and industrial branch circuit cable designed for power, lighting, control, and signaling loops. Constructed in a flat, parallel configuration rather than a traditional round profile, this Type TC (Tray Cable) variation features two standalone 12 AWG stranded bare copper conductors insulated with high-performance THHN\/THWN-2 cores, encased in a form-fitting, flame-retardant Polyvinyl Chloride (PVC) outer jacket.\u003c\/p\u003e\n\u003cp data-path-to-node=\"4\"\u003eThis specific variation utilizes \u003cb data-path-to-node=\"4\" data-index-in-node=\"33\"\u003eBlack and Red\u003c\/b\u003e insulation for clear phase-to-phase identification. The flat cross-sectional design makes it an exceptional choice for installation environments where vertical or horizontal space is highly restricted. It lays flat in shallow cable trays, fits neatly within compact low-profile wireways, and handles easily when pulled through structural raceways. This construction is highly favored for commercial automated lighting networks, 208V\/240V industrial signaling tracks, fractional horsepower motor feeds, and branch power runs where a separate structural grounding path is provided.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eAMPACITY RATINGS (NEC 310.16)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e60°C Terminal Rating: 20 AMPS\u003c\/b\u003e This is the baseline engineering safety rating. Use this value for final circuit sizing under normal operating conditions when connecting to legacy equipment terminals or standard breaker lugs restricted to 60°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e75°C Terminal Rating: 25 AMPS\u003c\/b\u003e This is the standard engineering design rating. Use this value for most standard modern terminal blocks, control relays, and electrical distribution equipment, as most modern industrial termination lugs are rated for 75°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e90°C Terminal Rating: 30 AMPS\u003c\/b\u003e This is the maximum capacity rating. Use this value strictly as the baseline calculation factor when adjusting or derating for high ambient operating temperatures, or when bundling multiple tray cables together in tightly packed industrial raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003ePhase-to-Phase Circuit Identification:\u003c\/b\u003e Features one Black and one Red conductor. This color scheme explicitly indicates a line-to-line circuit, preventing installation errors and speeding up testing and termination processes on complex industrial control panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eLow-Profile Flat Construction:\u003c\/b\u003e Wires are arranged parallel to one another rather than twisted, creating a thin, flat profile. This minimizes the physical footprint, eliminates unnecessary cable bulk, and maximizes space efficiency inside crowded shallow trays and raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eDual THHN \/ THWN-2 Conductor Insulation:\u003c\/b\u003e Inner copper conductors are wrapped in high-dielectric PVC and topped with a rugged clear nylon skin. This dual-layer architecture ensures superior resistance to oil, gasoline, moisture, and insulation scraping during difficult installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Sunlight Resistant:\u003c\/b\u003e Protected by an extruded, flame-retardant outer PVC jacket that forms an impermeable barrier against harsh ambient conditions, making it safe for open air tray runs, direct burial trenching, or wet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eHighly Conductive Bare Copper:\u003c\/b\u003e Manufactured with high-purity, soft-annealed stranded bare copper conductors to deliver optimal electrical conductivity, minimal line resistance, and sufficient physical flexibility for long pulled runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eRigorous Industrial Flame Ratings:\u003c\/b\u003e Engineered to prevent the migration of fire across open structural paths, fully certified to pass the demanding IEEE 1202 \/ UL 1685 vertical tray flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003e208V \/ 240V Control \u0026amp; Signaling Circuits:\u003c\/b\u003e Routing continuous line-to-line control signals, heavy-duty safety interlock loops, industrial machinery alarm relays, and contactor coils.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eCommercial Industrial Lighting:\u003c\/b\u003e Wiring automated facility high-voltage overhead lighting runs, industrial LED banks, and 208V outdoor security lighting loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eFractional Horsepower Motor Leads:\u003c\/b\u003e Supplying power directly to small 208V\/240V single-phase field motors, exhaust fans, and commercial HVAC damper controls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eSpace-Constrained Raceways:\u003c\/b\u003e Pulling through low-profile surface raceways, under-floor wireways, shallow control cabinet troughs, and tight structural partitions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eHazardous Environment Deployment:\u003c\/b\u003e Approved under strict National Electrical Code provisions for installation within Class I, Division 2 hazardous industrial locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCircuit Identification: Black\/Red Color Code\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black Insulation (Line 1 \/ Hot Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red Insulation (Line 2 \/ Hot Phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003ci data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eNote: Surface tracking information is continuously printed on the black outer PVC jacket for compliance auditing.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"15\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003eNumber of Wires:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eCable Geometry:\u003c\/b\u003e Flat (Parallel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,4,0\"\u003e\u003cb data-path-to-node=\"16,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PVC with Nylon Skin (THHN\/THWN-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,5,0\"\u003e\u003cb data-path-to-node=\"16,5,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,6,0\"\u003e\u003cb data-path-to-node=\"16,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,7,0\"\u003e\u003cb data-path-to-node=\"16,7,0\" data-index-in-node=\"0\"\u003eMaximum Temperature Rating:\u003c\/b\u003e 90°C Dry \/ 90°C Wet Continuous Operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,8,0\"\u003e\u003cb data-path-to-node=\"16,8,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e IEEE 1202, UL 1685 Vertical Tray Flame Test, FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"16,9,0\"\u003e\u003cb data-path-to-node=\"16,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 1277 (Type TC), NEC Article 336, Type THHN\/THWN-2 Conductors, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When engineering layouts with 12 AWG flat tray cable, the installer must account for the \u003cb data-path-to-node=\"18\" data-index-in-node=\"105\"\u003eNEC \"Small Conductor\" rule (NEC 240.4(D))\u003c\/b\u003e. Even though the physical 90°C thermal threshold of a 12 AWG copper conductor allows it to carry 30 Amps safely, the electrical code mandates that the overcurrent protection device (the circuit breaker) cannot exceed \u003cb data-path-to-node=\"18\" data-index-in-node=\"364\"\u003e20 Amps\u003c\/b\u003e under standard branch circuit conditions. However, the higher 30-Amp rating remains highly useful as a mathematical starting point when calculating derating factors for high ambient facility heat or when stacking multiple flat cables closely together in a single open-air cable tray.\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 2-Conductor Flat Stranded Parallel THHN\/PVC Type TC Tray Cable (Black\/Red, No Ground)\u003c\/p\u003e\n\u003cp data-path-to-node=\"21\"\u003e\u003cb data-path-to-node=\"21\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Commercial lighting grids, industrial control loops, and tray distribution paths must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant industrial safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing physical system designs or cutting structural cable lengths.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52577022148922,"sku":"TCTHN12-2-250","price":212.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52577022181690,"sku":"TCTHN12-2-500","price":422.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52577022214458,"sku":"TCTHN12-2-1K","price":839.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52577022247226,"sku":"TCTHN12-2-2500","price":2086.0,"currency_code":"USD","in_stock":true},{"title":"5000 ft. Spool","offer_id":52577022279994,"sku":"TCTHN12-2-5K","price":4150.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52577022312762,"sku":"TCTHN12-2-FT","price":0.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Tray_Cable_THHN_PVC_2C_Flat_Jacket_6e9a8033-19ac-4ce0-9b4f-aa514a63e9ac.jpg?v=1763585265","url":"https:\/\/www.wireamerica.com\/products\/12-2-tray-cable-thhn-pvc-vntc","provider":"Wire America ","version":"1.0","type":"link"}