{"product_id":"1111-mcm-diesel-locomotive-cable-2kv","title":"1111 MCM Diesel Locomotive Cable, 2000V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e1111 MCM Diesel Locomotive Cable (DLO)\u003c\/b\u003e is an ultra-heavy-duty, single-conductor portable power cable designed for massive industrial power distribution networks and maximum high-stress electrical setups. Engineered to safely manage a continuous electrical pressure of \u003cb data-path-to-node=\"1\" data-index-in-node=\"268\"\u003e2000 Volts\u003c\/b\u003e, this high-capacity power line is built to survive heavy vibration, aggressive mechanical handling, and unforgiving field conditions.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eWhile originally developed to feed high-voltage electrical energy from traction generators to the drive motors of heavy diesel-electric locomotives, its raw strength and exceptional flexibility make it a top choice for stationary and mobile applications. It serves as an ultra-flexible alternative to standard, stiff commercial building wire (such as THHN or XHHW-2) in complex commercial installations requiring tight bends or continuous dynamic motion.\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eELECTRICAL AMPACITY \u0026amp; PERFORMANCE DATA\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eThanks to its dense network of fine-drawn strands and a thick dual-layer insulation assembly, 1111 MCM DLO exhibits outstanding thermal dissipation properties and ultra-high-current handling limits:\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eMaximum Current Capacity (30 degrees C Ambient Air): 1225 AMPS\u003c\/b\u003e This premium capacity rating is evaluated based on a continuous 90 degrees C conductor temperature operating in an open-air cable tray environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eNational Electrical Code Adjustments:\u003c\/b\u003e When packing multiple single-conductor 1111 MCM DLO lines inside a closed structural conduit, wire trough, or enclosed raceway, electricians must apply NEC Article 310 derating adjustments based on ambient room temperatures and total enclosed conductor counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eExtreme-Flexibility Class I Tinned Copper Conductor:\u003c\/b\u003e Composed of 2755 individual strands of fully annealed tinned copper. This ultra-fine layout allows a massive 1,111,000 circular mil (MCM) conductor to bend smoothly around architectural structures without kinking, while the outer tin layer neutralizes copper oxidation and simplifies lug terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003ePremium EPR (Ethylene Propylene Rubber) Insulation:\u003c\/b\u003e Shielded by a thick layer of high-dielectric EPR insulation. This thermoset material resists softening, melting, or cracking under extreme temperature fluctuations and protects the core against internal voltage tracking failures under 2000V loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eHeavy-Duty CPE (Chlorinated Polyethylene) Outer Jacket:\u003c\/b\u003e Wrapped in an industrial-grade, abrasion-resistant black CPE jacket. It stands up to grease, fuel oils, petrochemical solvents, ozone, severe structural impacts, and nonstop open-air sunlight exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eMulti-Certified Safety Standard Ratings:\u003c\/b\u003e Dual-listed as Type RHH\/RHW-2 under UL 44, making it fully code-compliant for continuous permanent installation at 90 degrees C in both wet and dry architectural applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eDiesel-Electric Locomotive Networks:\u003c\/b\u003e Distributing high-amp energy paths between central engine generator blocks, dynamic braking grids, and heavy-duty wheel traction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eOil and Gas Drilling Rigs:\u003c\/b\u003e Powering massive mud pumps, top drives, drawworks equipment, and offshore marine drilling platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eData Centers \u0026amp; Bulk Battery Storage Hubs:\u003c\/b\u003e Interconnecting massive Uninterruptible Power Supply (UPS) systems, utility-scale battery storage arrays, and high-voltage emergency backup setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eIndustrial Motor \u0026amp; Generator Leads:\u003c\/b\u003e Acting as a flexible, high-current feeder line on mining shovels, heavy manufacturing motors, and large mobile generator sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eShipboard \u0026amp; Marine Power Distribution:\u003c\/b\u003e Supplying heavy-duty flexible power trunks across shipyards, commercial transport vessels, and marine docks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCable Layer Architecture (From Core to Jacket)\u003c\/h4\u003e\n\u003col start=\"1\" data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eCentral Conductor:\u003c\/b\u003e 1111 MCM rope-lay, bunch-stranded tinned copper core (2755\/24 layout configuration).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eSeparator Layer:\u003c\/b\u003e Clear polyester or paper binding tape to prevent the fine copper strands from sticking to the primary insulation layer during high-heat stripping and termination work.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003ePrimary Insulation:\u003c\/b\u003e Premium-grade Ethylene Propylene Rubber (EPR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eOuter Protective Armor:\u003c\/b\u003e Rugged, thermoset, weather-proof Black Chlorinated Polyethylene (CPE) jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-path-to-node=\"14\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"15\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,0,0\"\u003e\u003cb data-path-to-node=\"15,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 1111 MCM (1,111,000 Circular Mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,1,0\"\u003e\u003cb data-path-to-node=\"15,1,0\" data-index-in-node=\"0\"\u003eConductor Stranding Count:\u003c\/b\u003e 2755 Strands (24 AWG individual strand size)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,2,0\"\u003e\u003cb data-path-to-node=\"15,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Tinned Annealed Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,3,0\"\u003e\u003cb data-path-to-node=\"15,3,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e Ethylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,4,0\"\u003e\u003cb data-path-to-node=\"15,4,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e Chlorinated Polyethylene (CPE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,5,0\"\u003e\u003cb data-path-to-node=\"15,5,0\" data-index-in-node=\"0\"\u003eNominal Outer Diameter:\u003c\/b\u003e Approx. 1.75 to 1.84 inches (Varies slightly by manufacturer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,6,0\"\u003e\u003cb data-path-to-node=\"15,6,0\" data-index-in-node=\"0\"\u003eApproximate Net Weight:\u003c\/b\u003e Approx. 4150 to 4300 lbs per 1000 feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,7,0\"\u003e\u003cb data-path-to-node=\"15,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 2000 Volts Maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,8,0\"\u003e\u003cb data-path-to-node=\"15,8,0\" data-index-in-node=\"0\"\u003eMaximum Conductor Temperature:\u003c\/b\u003e 90 degrees C (Continuous wet or dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"15,9,0\"\u003e\u003cb data-path-to-node=\"15,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL Listed Type RHH\/RHW-2, CSA Type RW90\/RW90-TC (1kV), MSHA Approved (Mine Safety), ICEA S-95-658, NEMA WC-70, IEEE 1202\/FT4 Flame Test Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eTechnical Note Regarding Lugs:\u003c\/b\u003e Because 1111 MCM DLO cable is engineered with extra-fine Class I stranding, \u003cb data-path-to-node=\"17\" data-index-in-node=\"107\"\u003estandard mechanical compression lugs or standard commercial building wire barrels must never be used\u003c\/b\u003e. Trying to crush fine stranding into a standard building wire lug will tear the individual copper fibers and create a serious fire hazard due to loose electrical connections. Installers must exclusively use specialty chamfered compression lugs explicitly stamped and rated for \"Flexible Strand, Class I, or DLO Cable\" and secure them using calibrated crimping dies.\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 1111 MCM Single-Conductor Flexible 2000V Diesel Locomotive Power Cable (Black CPE Jacket)\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Industrial high-voltage power networks and flexible cable trays must strictly comply with the National Electrical Code (NEC), local municipal safety enforcement mandates, and individual equipment installation datasheets. Always verify official product submittal listings and exact core metrics with your electrical component manufacturer prior to configuring terminal arrays or subjecting lines to high pulling forces.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981897826618,"sku":"DLO1111-250","price":11958.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981897859386,"sku":"DLO1111-500","price":23795.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981897892154,"sku":"DLO1111-1K","price":47346.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981897924922,"sku":"DLO1111-FT","price":48.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/1111-mcm-diesel-locomotive-dlo-cable-2000v.jpg?v=1782422406","url":"https:\/\/www.wireamerica.com\/products\/1111-mcm-diesel-locomotive-cable-2kv","provider":"Wire America ","version":"1.0","type":"link"}