{"product_id":"10-5-tray-cable-thhn-pvc-vntc","title":"10\/5 VNTC Tray Cable Type TC-ER (THHN PVC 600V)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e10 AWG 5-Conductor VNTC (Vinyl Nylon Tray Cable) without Ground (Black, Red, Blue, Orange, Yellow Conductors)\u003c\/b\u003e is a heavy-duty, multi-conductor industrial power, branch circuit, and machinery control cable engineered for installation in open cable trays, structural conduits, and commercial wireways. Comprising five standalone 10 AWG stranded bare copper conductors twisted into a balanced round core, this Type TC (Tray Cable) assembly utilizes high-performance THHN\/THWN-2 insulation cores wrapped in a rugged, flame-retardant, and sunlight-resistant Polyvinyl Chloride (PVC) outer jacket.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThis specific variation utilizes a vibrant \u003cb data-path-to-node=\"2\" data-index-in-node=\"43\"\u003eBlack, Red, Blue, Orange, and Yellow\u003c\/b\u003e insulation color scheme. This multi-wire industrial layout is ideal for tracking complex three-phase systems requiring additional dedicated paths (such as separate control legs, auxiliary signaling paths, or multiple ungrounded circuits sharing a common area) where an independent structural grounding path or external ground wire is utilized.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eAMPACITY RATINGS (NEC 310.16)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e60°C Terminal Rating: 30 AMPS\u003c\/b\u003e This is the baseline engineering safety rating. Use this value for final circuit sizing under normal operating conditions when connecting to legacy equipment terminals or standard breaker lugs restricted to 60°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003e75°C Terminal Rating: 35 AMPS\u003c\/b\u003e This is the standard engineering design rating. Use this value for most standard modern terminal blocks, motor starters, and electrical distribution equipment, as most modern industrial termination lugs are rated for 75°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003e90°C Terminal Rating: 40 AMPS\u003c\/b\u003e This is the maximum capacity rating. Use this value strictly as the baseline calculation factor when adjusting or derating for high ambient operating temperatures, or when bundling multiple tray cables together in tightly packed industrial raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Industrial Color Coding:\u003c\/b\u003e Features individual Black, Red, Blue, Orange, and Yellow conductors. This color profile provides immediate, distinct visual tracking across complex terminal strips, minimizing wiring errors and speeding up field system diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eIndustrial Round Profile Construction:\u003c\/b\u003e Wires are twisted inside the jacket into a nested round layout, maximizing physical symmetry. This structural design ensures uniform pulling tension, high physical strength, and smooth feeding through multi-bend conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDual THHN \/ THWN-2 Conductor Insulation:\u003c\/b\u003e Inner copper conductors are wrapped in high-dielectric PVC and topped with a rugged clear nylon skin. This dual-layer architecture ensures superior resistance to oil, gasoline, moisture, and insulation scraping during difficult installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Sunlight Resistant:\u003c\/b\u003e Protected by an extruded, flame-retardant outer PVC jacket that forms an impermeable barrier against harsh ambient conditions, making it safe for open-air tray runs, direct burial trenching, or wet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eHighly Conductive Bare Copper:\u003c\/b\u003e Manufactured with high-purity, soft-annealed stranded bare copper conductors to deliver optimal electrical conductivity, minimal line resistance, and sufficient physical flexibility for long pulled runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eRigorous Industrial Flame Ratings:\u003c\/b\u003e Engineered to prevent the migration of fire across open structural paths, fully certified to pass the demanding IEEE 1202 \/ UL 1685 vertical tray flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eComplex Industrial Control Loops:\u003c\/b\u003e Supplying continuous signaling and control power to multi-motor control centers (MCCs), automated assembly tracks, large process valves, and machinery console relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eMulti-Wire Branch \u0026amp; Auxiliary Circuits:\u003c\/b\u003e Routing distinct control legs alongside standard three-phase ungrounded power paths within automated production lines and processing areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eCommercial Industrial Lighting:\u003c\/b\u003e Wiring multi-circuit branch lighting grids, automated facility overhead lighting banks, and zoned industrial LED arrays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eUtility Feeder \u0026amp; Branch Distribution:\u003c\/b\u003e Pulling branch infrastructure connections through structural conduits, commercial utility tunnels, underground duct banks, or open-air wire mesh trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eHazardous Environment Deployment:\u003c\/b\u003e Approved under strict National Electrical Code provisions for installation within Class I, Division 2 hazardous industrial locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCircuit Identification: Standard 5-Conductor Phasing\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black Insulation (Phase\/Line Leg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red Insulation (Phase\/Line Leg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e Blue Insulation (Phase\/Line Leg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eConductor 4:\u003c\/b\u003e Orange Insulation (Auxiliary \/ Phase Leg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eConductor 5:\u003c\/b\u003e Yellow Insulation (Auxiliary \/ Phase Leg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,5,0\"\u003e\u003ci data-path-to-node=\"12,5,0\" data-index-in-node=\"0\"\u003eNote: Surface tracking information is continuously printed on the black outer PVC jacket for compliance auditing.\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eNumber of Wires:\u003c\/b\u003e 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eCable Geometry:\u003c\/b\u003e Round (Twisted Core)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PVC with Nylon Skin (THHN\/THWN-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\"\u003e\u003cb data-path-to-node=\"14,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,7,0\"\u003e\u003cb data-path-to-node=\"14,7,0\" data-index-in-node=\"0\"\u003eMaximum Temperature Rating:\u003c\/b\u003e 90°C Dry \/ 90°C Wet Continuous Operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,8,0\"\u003e\u003cb data-path-to-node=\"14,8,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e IEEE 1202, UL 1685 Vertical Tray Flame Test, FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,9,0\"\u003e\u003cb data-path-to-node=\"14,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 1277 (Type TC), NEC Article 336, Type THHN\/THWN-2 Conductors, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When engineering layouts with 10 AWG 5-conductor VNTC tray cable, installers must apply mandatory \u003cb data-path-to-node=\"16\" data-index-in-node=\"114\"\u003eampacity adjustment factors\u003c\/b\u003e per NEC Article 310.15(C)(1) because more than three conductors are bundled within a single jacket core. For a 5-conductor configuration where all lines carry active continuous current, the bundle must be derated to \u003cb data-path-to-node=\"16\" data-index-in-node=\"358\"\u003e80%\u003c\/b\u003e of its 90°C ampacity baseline calculation factor (40 Amps × 0.80 = 32 Amps). Additionally, the installer must account for the \u003cb data-path-to-node=\"16\" data-index-in-node=\"488\"\u003eNEC \"Small Conductor\" rule (NEC 240.4(D))\u003c\/b\u003e, which mandates that the standard maximum overcurrent protection device (the circuit breaker) cannot exceed \u003cb data-path-to-node=\"16\" data-index-in-node=\"638\"\u003e30 Amps\u003c\/b\u003e under standard branch circuit parameters.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 5-Conductor Stranded Round THHN\/PVC Type TC Tray Cable (Black\/Red\/Blue\/Orange\/Yellow, No Ground)\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Large-scale industrial power distribution paths, tray layouts, and machinery connections must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant industrial safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing physical system designs or cutting structural cable lengths.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52577027653946,"sku":"TCTHN10-5-250","price":764.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52577027686714,"sku":"TCTHN10-5-500","price":1519.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52577027719482,"sku":"TCTHN10-5-1K","price":3023.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52577027752250,"sku":"TCTHN10-5-2500","price":7518.0,"currency_code":"USD","in_stock":true},{"title":"5000 ft. Spool","offer_id":52577027785018,"sku":"TCTHN10-5-5K","price":14958.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52577027817786,"sku":"TCTHN10-5-FT","price":3.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Tray_Cable_THHN_PVC_5C_6d50c977-68bb-4da7-932a-ce5f0b7896ee.jpg?v=1763585285","url":"https:\/\/www.wireamerica.com\/products\/10-5-tray-cable-thhn-pvc-vntc","provider":"Wire America ","version":"1.0","type":"link"}