{"product_id":"10-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 3-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488715071802,"sku":"SUB10-3-20\/10-250","price":1003.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488715104570,"sku":"SUB10-3-20\/10-500","price":1995.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488715137338,"sku":"SUB10-3-20\/10-1K","price":3969.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488715170106,"sku":"SUB10-3-20\/10-FT","price":4.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887199","url":"https:\/\/www.wireamerica.com\/products\/10-3-unshielded-substation-control-cable-20-10-pe-pvc","provider":"Wire America","version":"1.0","type":"link"}