{"product_id":"10-12-tray-cable-thhn-pvc-vntc","title":"10\/12 VNTC Tray Cable Type TC-ER (THHN PVC 600V)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e10 AWG 12-Conductor VNTC (Vinyl Nylon Tray Cable) is a heavy-duty industrial control, signaling, and power distribution cable engineered for installation in commercial wireways, open cable trays, and structural conduits.\u003c\/b\u003e Featuring twelve 10 AWG conductors twisted into a compact, balanced round core, this multi-conductor Type TC (Tray Cable) assembly utilizes high-performance THHN\/THWN-2 inner conductor insulation wrapped in a rugged, flame-retardant, and sunlight-resistant Polyvinyl Chloride (PVC) outer jacket.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eThis configuration provides a highly durable, moisture-resistant wiring system optimized for routing high-capacity multi-wire branch control loops, automated logic circuits, heavy signaling arrays, and multi-circuit utility power feeds. It is designed for demanding overhead or underground raceways where a separate structural grounding path or external ground wire is utilized.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eAMPACITY RATINGS (NEC 310.16)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e60°C Terminal Rating: 30 AMPS\u003c\/b\u003e This is the baseline engineering safety rating. Use this value for final circuit sizing under normal operating conditions when connecting to legacy equipment terminals or standard breaker lugs restricted to 60°C constraints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003e75°C Terminal Rating: 35 AMPS\u003c\/b\u003e This is the standard engineering design rating. Use this value for modern industrial terminal configurations, as it represents the typical maximum operational ampacity for a standard 10 AWG copper conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003e90°C Terminal Rating: 40 AMPS\u003c\/b\u003e This is the maximum capacity rating. Use this value strictly as the baseline calculation factor when adjusting or derating for high ambient operating temperatures, or when bundling multiple tray cables together in packed industrial raceways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eIndustrial Round Profile Construction:\u003c\/b\u003e Wires are twisted inside the jacket into a nested layout, maximizing physical roundness and structural symmetry. This ensures uniform pulling tension, high physical strength, and smooth feeding through multi-bend conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDual THHN \/ THWN-2 Conductor Insulation:\u003c\/b\u003e Inner copper conductors are wrapped in high-dielectric PVC and topped with a rugged clear nylon skin. This dual-layer architecture ensures superior resistance to oil, gasoline, moisture, and insulation scraping during difficult installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Sunlight Resistant:\u003c\/b\u003e Protected by an extruded, flame-retardant outer PVC jacket that forms an impermeable barrier against harsh ambient conditions, making it safe for open air tray runs, direct burial trenching, or wet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eHighly Conductive Bare Copper:\u003c\/b\u003e Manufactured with high-purity, soft-annealed stranded bare copper conductors to deliver optimal electrical conductivity, minimal line resistance, and sufficient physical flexibility for long pulled runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eRigorous Industrial Flame Ratings:\u003c\/b\u003e Engineered to prevent the migration of fire across open structural paths, fully certified to pass the demanding IEEE 1202 \/ UL 1685 vertical tray flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eIndustrial Control \u0026amp; Power Signaling:\u003c\/b\u003e Routing heavy command inputs, multi-stage relay logic tracks, motor control centers (MCCs), and high-draw automated machinery fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eMulti-Wire Branch Distribution:\u003c\/b\u003e Supplying continuous branch power to automated production lines, multi-wire sub-circuits requiring dedicated indicators, and heavy industrial machinery processing lanes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eConduit and Wireway Routing:\u003c\/b\u003e Pulling robust multi-circuit infrastructure connections through structural conduits, commercial utility tunnels, underground duct banks, or open-air wire mesh trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eHazardous Environment Deployment:\u003c\/b\u003e Approved under strict National Electrical Code provisions for installation within Class I, Division 2 hazardous industrial locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCircuit Identification: Standard 12-Conductor Color Code (ICEA Method 1, Table E-2)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eConductor 4:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eConductor 5:\u003c\/b\u003e Yellow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,5,0\"\u003e\u003cb data-path-to-node=\"12,5,0\" data-index-in-node=\"0\"\u003eConductor 6:\u003c\/b\u003e Brown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,6,0\"\u003e\u003cb data-path-to-node=\"12,6,0\" data-index-in-node=\"0\"\u003eConductor 7:\u003c\/b\u003e Red with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,7,0\"\u003e\u003cb data-path-to-node=\"12,7,0\" data-index-in-node=\"0\"\u003eConductor 8:\u003c\/b\u003e Blue with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,8,0\"\u003e\u003cb data-path-to-node=\"12,8,0\" data-index-in-node=\"0\"\u003eConductor 9:\u003c\/b\u003e Orange with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,9,0\"\u003e\u003cb data-path-to-node=\"12,9,0\" data-index-in-node=\"0\"\u003eConductor 10:\u003c\/b\u003e Yellow with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,10,0\"\u003e\u003cb data-path-to-node=\"12,10,0\" data-index-in-node=\"0\"\u003eConductor 11:\u003c\/b\u003e Brown with Black Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,11,0\"\u003e\u003cb data-path-to-node=\"12,11,0\" data-index-in-node=\"0\"\u003eConductor 12:\u003c\/b\u003e Black with Red Stripe (Tracer)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,12,0\"\u003e\u003ci data-path-to-node=\"12,12,0\" data-index-in-node=\"0\"\u003eNote: Depending on the specific manufacturer or project specification, 12-conductor configurations may alternatively be provided with uniform black insulation featuring high-visibility, continuous alphanumeric numbers (1 through 12).\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eNumber of Power\/Control Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eConductor Type:\u003c\/b\u003e Stranded Bare Copper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eInsulation Material:\u003c\/b\u003e PVC with Nylon Skin (THHN\/THWN-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\"\u003e\u003cb data-path-to-node=\"14,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,7,0\"\u003e\u003cb data-path-to-node=\"14,7,0\" data-index-in-node=\"0\"\u003eMaximum Temperature Rating:\u003c\/b\u003e 90°C Dry \/ 90°C Wet Continuous Operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,8,0\"\u003e\u003cb data-path-to-node=\"14,8,0\" data-index-in-node=\"0\"\u003eFlame Test Ratings:\u003c\/b\u003e IEEE 1202, UL 1685 Vertical Tray Flame Test, FT4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,9,0\"\u003e\u003cb data-path-to-node=\"14,9,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 1277 (Type TC), NEC Article 336, Type THHN\/THWN-2 Conductors, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e When engineering layouts with 10 AWG multi-conductor cables like the 10-12 VNTC, installers must apply severe \u003cb data-path-to-node=\"16\" data-index-in-node=\"126\"\u003eampacity adjustment factors for more than three current-carrying conductors\u003c\/b\u003e per NEC Article 310.15(C)(1). For a 12-conductor cable where all lines carry continuous current, the ampacity must be severely derated down to \u003cb data-path-to-node=\"16\" data-index-in-node=\"345\"\u003e50%\u003c\/b\u003e of its baseline rating. Using the 90°C baseline calculation factor (40 Amps), the adjusted calculated ampacity factor drops to \u003cb data-path-to-node=\"16\" data-index-in-node=\"476\"\u003e20.0 Amps\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003eAdditionally, the installer must account for the \u003cb data-path-to-node=\"17\" data-index-in-node=\"49\"\u003eNEC \"Small Conductor\" rule (NEC 240.4(D))\u003c\/b\u003e, which mandates that the standard maximum overcurrent protection device (the circuit breaker) for a 10 AWG conductor cannot exceed \u003cb data-path-to-node=\"17\" data-index-in-node=\"222\"\u003e30 Amps\u003c\/b\u003e under normal branch circuit conditions. However, because the intense multi-conductor core heat constraints choke the actual calculated ampacity threshold down to 20.0 Amps, you must fuse the circuit accordingly if those lines are carrying continuous maximum loads simultaneously.\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 12-Conductor Stranded Round THHN\/PVC Type TC Tray Cable (No Ground)\u003c\/p\u003e\n\u003cp data-path-to-node=\"20\"\u003e\u003cb data-path-to-node=\"20\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Large-scale industrial control pathways, tray layouts, and machinery connections must strictly adhere to the National Electrical Code (NEC), local building structures, and relevant industrial safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing physical system designs or cutting structural cable lengths.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52577029882170,"sku":"TCTHN10-12-250","price":1919.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52577029914938,"sku":"TCTHN10-12-500","price":3818.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52577029947706,"sku":"TCTHN10-12-1K","price":7596.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52577029980474,"sku":"TCTHN10-12-2500","price":18891.0,"currency_code":"USD","in_stock":true},{"title":"5000 ft. Spool","offer_id":52577030013242,"sku":"TCTHN10-12-5K","price":37587.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52577030046010,"sku":"TCTHN10-12-FT","price":7.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Tray_Cable_THHN_PVC_12C_51c8448a-57a1-400c-ae3c-5d5a5a22456d.jpg?v=1763585290","url":"https:\/\/www.wireamerica.com\/products\/10-12-tray-cable-thhn-pvc-vntc","provider":"Wire America ","version":"1.0","type":"link"}