{"product_id":"1-3c-w-ground-18-9c-generator-cable-ul-type-tc-er-jp-130amp","title":"Generator Cable, 1\/3C w\/ Ground + 18\/9C, 130 Amps, 28kW, 600V","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e1\/3C + 18\/9C w\/ Ground Generator Cable (TC-ER-JP)\u003c\/b\u003e is a high-capacity, multi-conductor composite power and control tray cable specifically engineered for heavy-duty whole-house and light commercial standby generator installations rated up to \u003cb data-path-to-node=\"1\" data-index-in-node=\"241\"\u003e28kW\u003c\/b\u003e.\u003c\/p\u003e\n\u003cp data-path-to-node=\"2\"\u003eInstead of routing multiple bulky feeders and control wires through rigid conduits, this integrated cable combines the \u003cb data-path-to-node=\"2\" data-index-in-node=\"119\"\u003e130 Amp power supply lines\u003c\/b\u003e, the \u003cb data-path-to-node=\"2\" data-index-in-node=\"151\"\u003eground conductor\u003c\/b\u003e, and \u003cb data-path-to-node=\"2\" data-index-in-node=\"173\"\u003e9 control\/sensing wires\u003c\/b\u003e into a single, compact, and durable outer jacket.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eELECTRICAL AMPACITY \u0026amp; RATING\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eCurrent Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"16\"\u003e130 AMPS\u003c\/b\u003e (based on 75°C terminal temperature rating parameters per NEC rules).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eGenerator Compatibility:\u003c\/b\u003e Engineered for \u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"40\"\u003e28kW\u003c\/b\u003e standby generator systems (such as Generac, Kohler, Cummins, and Briggs \u0026amp; Stratton).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e \u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"16\"\u003e600 Volts\u003c\/b\u003e maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eAll-in-One Composite Construction:\u003c\/b\u003e Integrates heavy 1 AWG main power conductors, an insulated ground line, and 9 dedicated control wires under one heavy-duty sheath, saving hours of pull labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eType TC-ER-JP Listed:\u003c\/b\u003e Approved as Tray Cable - Exposed Run with \u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"64\"\u003eJoist Pull (JP)\u003c\/b\u003e certification, allowing open runs through residential floor joists and wall framing without needing continuous conduit runs (per NEC Article 336).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Weather Protection:\u003c\/b\u003e Extruded with a heavy, sunlight-resistant (SUN RES) PVC jacket engineered for direct earth burial, open cable trays, or interior structural framing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eIndustrial Resistance:\u003c\/b\u003e Rated for severe cold-bend installations (-40°C) and fully compliant with FT4 \/ IEEE vertical flame tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCable Layer Architecture (From Core to Outer Sheath)\u003c\/h4\u003e\n\u003col start=\"1\" data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003ePower Conductors (3 x 1 AWG):\u003c\/b\u003e Stranded bare copper cores insulated with THHN\/THWN-2 (PVC\/Nylon) for delivering 240V multi-phase generator output straight to the Automatic Transfer Switch (ATS).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eGround Conductor (1 x 6 AWG):\u003c\/b\u003e Stranded bare copper grounding wire (typically insulated green) for full equipment bonding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eControl\/Sensing Conductors (9 x 18 AWG):\u003c\/b\u003e Stranded copper control wires utilized for utility voltage sensing, 24V signal relays, battery trickling, exercise clock circuits, and generator status indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eCore Fillers \u0026amp; Binder:\u003c\/b\u003e Non-hygroscopic polypropylene fillers with mylar core wrap to ensure roundness and mechanical stability during tight pulls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eOuter Jacket:\u003c\/b\u003e Heavy-duty, UV- and moisture-resistant Black or Orange PVC outer jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003ePower Conductor Size:\u003c\/b\u003e 1 AWG Stranded Copper (3 Conductors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eGround Conductor Size:\u003c\/b\u003e 6 AWG Stranded Copper (1 Conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eControl Conductor Size:\u003c\/b\u003e 18 AWG Stranded Copper (9 Conductors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e PVC with Nylon skin (THHN\/THWN-2 rated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eJacket Material:\u003c\/b\u003e Sunlight-resistant, direct-burial PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,5,0\"\u003e\u003cb data-path-to-node=\"14,5,0\" data-index-in-node=\"0\"\u003eOverall Outside Diameter:\u003c\/b\u003e Approx. 1.25 to 1.35 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,6,0\"\u003e\u003cb data-path-to-node=\"14,6,0\" data-index-in-node=\"0\"\u003eApproximate Net Weight:\u003c\/b\u003e Approx. 1,380 lbs per 1000 feet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,7,0\"\u003e\u003cb data-path-to-node=\"14,7,0\" data-index-in-node=\"0\"\u003eTemperature Limits:\u003c\/b\u003e 90°C Dry \/ 75°C Wet (restricted to 75°C terminal ratings for ampacity calculations)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,8,0\"\u003e\u003cb data-path-to-node=\"14,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL Standard 1277 (Type TC-ER), UL 83, FT4\/IEEE 1202 Flame Rated, NEC Article 336 (TC-ER-JP), RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eTechnical Note Regarding Installation:\u003c\/b\u003e When pulling 1 AWG composite TC-ER cable, always maintain recommended minimum bend radii (typically 8 to 12 times overall cable diameter) to prevent crushing internal control pairs. Where the cable enters panels, transfer switches, or junction boxes, use code-approved TC cable glands or strain-relief fittings to guarantee watertight seal integrity and secure mechanical retention.\u003c\/p\u003e\n\u003cp data-path-to-node=\"17\"\u003e\u003cb data-path-to-node=\"17\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 1\/3C + 18\/9C w\/ 6 AWG Ground Type TC-ER-JP Multi-Conductor Generator Power \u0026amp; Control Cable (600V, 130A)\u003c\/p\u003e\n\u003cp data-path-to-node=\"19\"\u003e\u003cb data-path-to-node=\"19\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. All generator and Automatic Transfer Switch (ATS) installations must comply with the National Electrical Code (NEC), local municipal building codes, and manufacturer instructions, and must be performed by a qualified licensed electrician.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53787146879290,"sku":"GEN-TC9-1-3-250","price":4637.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53787146912058,"sku":"GEN-TC9-1-3-500","price":9227.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53787146944826,"sku":"GEN-TC9-1-3-1K","price":18360.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53787146977594,"sku":"GEN-TC9-1-3-FT","price":18.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/generator-cable-1-3c-ground-18-9c-130a-28kw.png?v=1784912719","url":"https:\/\/www.wireamerica.com\/products\/1-3c-w-ground-18-9c-generator-cable-ul-type-tc-er-jp-130amp","provider":"Wire America ","version":"1.0","type":"link"}