{"product_id":"1-0-4-conductor-direct-burial-aluminum-mc-cable","title":"1\/0-4C Direct Burial Aluminum MC Cable with Bare Ground (PVC Jacketed)","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003e1\/0 4-Conductor Direct Burial Aluminum MC (Metal Clad) Cable is a durable branch and feeder power distribution line engineered to handle demanding electrical paths across industrial plants, commercial parks, and municipal developments. Consisting of four 1\/0 AWG compact stranded AA-8000 series aluminum alloy power conductors paired with a bare aluminum ground wire, the cable is protected by a continuous Aluminum Interlocked Armor (AIA). Covered in a heavy-duty, sunlight-resistant polyvinyl chloride (PVC) outer jacket, this assembly is code-certified for direct burial in earth trenches or direct pour encasement within structural concrete walls, completely eliminating the labor and material costs of running rigid protective conduit networks.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eAMPACITY RATINGS (NEC 310.16)\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003e75°C Terminal Rating: 120 AMPS\u003c\/b\u003e This is the standard engineering design rating. Use this value for final circuit sizing under normal operating conditions, as most commercial breakers, distribution lugs, and equipment terminals are restricted to 75°C terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003e90°C Terminal Rating: 135 AMPS\u003c\/b\u003e This is the maximum capacity rating. Use this value strictly as the baseline calculation factor when adjusting or derating for high ambient temperatures, or when bundling multiple cables closely together in a single trench or tray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eVersatile 120A Power Delivery (1\/0 AWG):\u003c\/b\u003e Sized to provide dependable electrical feeder capacity for commercial sub-panels, retail facility service entries, and high-load mechanical room installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eFull 4-Conductor Configuration:\u003c\/b\u003e Built with 4 discrete power legs to comfortably run three-phase power along with a dedicated neutral, safely handling unbalanced current loads across multi-point commercial networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eDirect Burial \u0026amp; Concrete Encasement Rated:\u003c\/b\u003e The heavy-duty, sunlight-resistant outer PVC jacket forms an impermeable barrier against soil chemistry, corrosive moisture, and physical impact, permitting direct trenches or structural concrete encasement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eAA-8000 Aluminum Conductors:\u003c\/b\u003e Manufactured with premium 8000-series compact stranded aluminum alloy, offering an exceptionally lightweight, cost-effective alternative to copper feeders while maintaining stable electrical performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eAluminum Interlocked Armor (AIA):\u003c\/b\u003e Spirally wrapped interlocking metallic armor ensures high crush resistance, physical barrier security, and defense against boring pests, eliminating the labor and material costs of traditional pipe-and-wire conduit installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eCross-Linked Polyethylene Insulation:\u003c\/b\u003e Inner core conductors are insulated with high-dielectric, flame-retardant XHHW-2 \/ XLPE insulation, certified for stable continuous operation at temperatures up to 90 degrees C in both wet and dry applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eMain Feeders \u0026amp; Service Entrances:\u003c\/b\u003e Injecting raw power from outdoor utility transformers into high-capacity indoor distribution panels, switchgear arrays, and main disconnect hubs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eIndustrial \u0026amp; Heavy Manufacturing Layouts:\u003c\/b\u003e Routing high-amperage power across industrial environments, paper mills, foundries, mining sites, and petrochemical operations via open indoor or outdoor cable trays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eDirect Burial Site Distribution:\u003c\/b\u003e Burying underground branch and feeder circuits between commercial facilities, outer maintenance hubs, outbuildings, and municipal wastewater treatment zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eHazardous \u0026amp; Assembly Locations:\u003c\/b\u003e Permitted for use in environments such as arenas, theaters, casino main floors, and industrial hazardous zones (Class I \u0026amp; II, Division 2; Class III, Division 1 \u0026amp; 2) per strict NEC provisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCircuit Identification: Standard 4-Conductor Phases\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003ePhase 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003ePhase 2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003ePhase 3:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eNeutral:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eEquipment Ground:\u003c\/b\u003e 6 AWG Bare Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 1\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eNumber of Power Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e AA-8000 Series Compact Stranded Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eGround Wire Size:\u003c\/b\u003e 6 AWG Bare Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003eInsulation Type:\u003c\/b\u003e XLPE \/ XHHW-2 (Cross-Linked Polyethylene)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,5,0\"\u003e\u003cb data-path-to-node=\"13,5,0\" data-index-in-node=\"0\"\u003eArmor Type:\u003c\/b\u003e AIA (Aluminum Interlocked Armor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,6,0\"\u003e\u003cb data-path-to-node=\"13,6,0\" data-index-in-node=\"0\"\u003eProtective Outer Jacket:\u003c\/b\u003e PVC (Polyvinyl Chloride) - Black (Sunlight \u0026amp; Moisture Resistant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,7,0\"\u003e\u003cb data-path-to-node=\"13,7,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,8,0\"\u003e\u003cb data-path-to-node=\"13,8,0\" data-index-in-node=\"0\"\u003eApproximate Nominal Outer Diameter:\u003c\/b\u003e 1.37 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,9,0\"\u003e\u003cb data-path-to-node=\"13,9,0\" data-index-in-node=\"0\"\u003eApproximate Net Weight:\u003c\/b\u003e 0.81 lbs per foot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,10,0\"\u003e\u003cb data-path-to-node=\"13,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 44, UL 1569 (Type MC), NEMA WC70 \/ ICEA S-95-658, IEEE 1202 (70,000 BTU\/hr Vertical Tray Flame Test), RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e To prevent structural degradation from galvanic corrosion, installers must utilize dual-rated AL7CU or AL9CU mechanical compression lugs or mechanical split-bolts when joining this aluminum cable to copper busbars or breaker terminals. Penetrox or similar antioxidant joint compound must be thoroughly applied to all bare aluminum conductors before final structural torquing. While the PVC jacket isolates the interior armor against direct soil or chemical contact, minimum trench depth profiles must strictly comply with NEC Article 300.5 tables (typically requiring 24 inches of earth cover for direct-buried cables not under concrete paths, or 18 inches beneath standard structural landscapes).\u003c\/p\u003e\n\u003cp data-path-to-node=\"16\"\u003e\u003cb data-path-to-node=\"16\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 1\/0 AWG \/ 4-Conductor w\/ Ground Aluminum Jacketed MC Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Large-scale high-voltage feeder systems and underground distribution paths must strictly adhere to the National Electrical Code (NEC), local electrical building enforcement, and relevant safety parameters. Always cross-reference the official product submittal data sheet from the chosen manufacturer prior to finalizing structural configurations or executing structural cuts.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53532995617082,"sku":"MCA1\/0-4JKT-250","price":1857.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53532995649850,"sku":"MCA1\/0-4JKT-500","price":3695.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53532995682618,"sku":"MCA1\/0-4JKT-1K","price":7352.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53532995715386,"sku":"MCA1\/0-4JKT-FT","price":7.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/1-0-4c-aluminum-mc-cable-direct-burial-pvc-jacketed.jpg?v=1781015021","url":"https:\/\/www.wireamerica.com\/products\/1-0-4-conductor-direct-burial-aluminum-mc-cable","provider":"Wire America ","version":"1.0","type":"link"}