{"title":"ALUMINUM URD DIRECT BURIAL CABLE","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eAluminum Direct Burial, URD Cable (600V)\u003c\/strong\u003e\u003cspan\u003e, which stands for \u003c\/span\u003e\u003cstrong\u003eU\u003c\/strong\u003e\u003cspan\u003enderground \u003c\/span\u003e\u003cstrong\u003eR\u003c\/strong\u003e\u003cspan\u003eesidential \u003c\/span\u003e\u003cstrong\u003eD\u003c\/strong\u003e\u003cspan\u003eistribution cable, is an aluminum wire designed specifically for underground utility systems. It plays a key role in\u003cstrong\u003e \u003c\/strong\u003esecondary power distribution, carrying electricity from transformers directly to the service entrance or meter of homes and buildings. Also commonly used to provide power to\u003cstrong\u003e \u003c\/strong\u003edetached garages, shops, sheds, well pumps \u0026amp; septic systems. Read our \u003cspan style=\"color: rgb(128, 128, 128);\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003ca href=\"https:\/\/wireamerica.com\/blogs\/news\/what-is-aluminum-urd-direct-burial-cable\" title=\"Aluminum URD Direct Burial Cable Buyers Guide | Wire America\" style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eAluminum URD Direct Burial Cable Buyers Guide\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"princeton-6-gauge-aluminum-direct-burial-wire-urd","title":"6 Gauge Aluminum Direct Burial Wire, Princeton URD","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7\"\u003eWhy Choose 6 AWG Aluminum URD?\u003cbr\u003e\u003c\/b\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eTechnical Specifications: 6 AWG URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 6 AWG \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.309 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 90 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 65 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eCommon Applications\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-burial trenching or pull-through conduit.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"500 ft. Spool","offer_id":51981750468922,"sku":"PRN-URD-500","price":231.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981750501690,"sku":"PRN-URD-1K","price":459.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981750534458,"sku":"PRN-URD-FT","price":0.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Princeton_6_AWG_Single_Aluminum_URD_A_d6fb79b2-8cc2-4cfa-95b7-4d3948d27f2f.jpg?v=1760026618"},{"product_id":"mercer-4-gauge-aluminum-direct-burial-wire-urd","title":"4 Gauge Aluminum Direct Burial Wire, Mercer URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 2 AWG Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 2 AWG URD Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 2 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eOverall Diameter:\u003c\/b\u003e 0.357 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 120 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-path-to-node=\"10,6,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 85 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-path-to-node=\"10,7,0\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-burial trenching or pull-through conduit.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cb data-path-to-node=\"2,3,0\" data-index-in-node=\"0\"\u003eCustom Phase Management:\u003c\/b\u003e Because this is a single conductor, it is frequently used in custom underground layouts where the electrician needs to manage individual phases (for example, in complex commercial underground runs or when replacing a single damaged lead in an existing circuit).\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"500 ft. Spool","offer_id":51981751353658,"sku":"MER-URD-500","price":245.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981751386426,"sku":"MER-URD-1K","price":488.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981751419194,"sku":"MER-URD-FT","price":0.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Princeton_6_AWG_Single_Aluminum_URD_A_0854f919-47a4-4493-a430-92ee56b6a722.jpg?v=1760026619"},{"product_id":"clemson-2-gauge-aluminum-direct-burial-wire-urd","title":"2 Gauge Aluminum Direct Burial Wire, Clemson URD","description":"\u003cp data-path-to-node=\"5\"\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 2 AWG Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 2 AWG URD\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 2 AWG \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.418 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 155 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 115 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-trenching or pull-through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981751943482,"sku":"CLE-URD-250","price":168.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981751976250,"sku":"CLE-URD-500","price":334.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981752009018,"sku":"CLE-URD-1K","price":663.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981752041786,"sku":"CLE-URD-FT","price":0.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Princeton_6_AWG_Single_Aluminum_URD_A_dd88a31a-af3a-4cf7-a9b2-cacfc4a1e6d3.jpg?v=1760026618"},{"product_id":"kenyon-1-gauge-aluminum-direct-burial-wire-urd","title":"1 Gauge Aluminum Direct Burial Wire, Kenyon URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 1 AWG Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 1 AWG URD Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 1 AWG \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.500 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 175 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 130 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-trenching or pull-through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981751189818,"sku":"KEN-URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981751222586,"sku":"KEN-URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981751255354,"sku":"KEN-URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981751288122,"sku":"KEN-URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/kenyon-1-awg-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775592198"},{"product_id":"harvard-1-0-aluminum-direct-burial-wire-urd","title":"1\/0 Aluminum Direct Burial Wire, Harvard URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 1\/0 AWG Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 1\/0 URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 1\/0 AWG \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.540 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 200 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 150 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable high-capacity sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-trenching or pull-through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cb data-index-in-node=\"0\" data-path-to-node=\"2,3,0\"\u003eCustom Phase Management:\u003c\/b\u003e\u003cspan\u003e Because this is a single conductor, it is frequently used in custom underground layouts where the electrician needs to manage individual phases (for example, in complex commercial underground runs or when replacing a single damaged lead in an existing circuit).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981755154746,"sku":"HAR-URD-250","price":222.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981755187514,"sku":"HAR-URD-500","price":441.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981755220282,"sku":"HAR-URD-1K","price":878.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981755253050,"sku":"HAR-URD-FT","price":0.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/harvard-1-0-awg-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775592074"},{"product_id":"yale-2-0-aluminum-direct-burial-wire-urd","title":"2\/0 Aluminum Direct Burial Wire, Yale URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 2\/0 Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 2\/0 AWG URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 2\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.586 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 225 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 170 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,1,0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,2,0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-trenching or pull-through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981755023674,"sku":"YAL-URD-250","price":262.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981755056442,"sku":"YAL-URD-500","price":520.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981755089210,"sku":"YAL-URD-1K","price":1034.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981755121978,"sku":"YAL-URD-FT","price":1.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/yale-2-0-awg-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591965"},{"product_id":"tufts-3-0-aluminum-direct-burial-wire-urd","title":"3\/0 Aluminum Direct Burial Wire,Tufts URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 3\/0 Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 3\/0 AWG URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 3\/0 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eOverall Diameter:\u003c\/b\u003e 0.638 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 250 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-path-to-node=\"10,6,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 195 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-path-to-node=\"10,7,0\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eSecondary Underground Distribution:\u003c\/b\u003e Power feed from transformer to service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eResidential \u0026amp; Farm Power:\u003c\/b\u003e Reliable sub-panel feeds and outbuilding power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eUnderground Routing:\u003c\/b\u003e Ideal for direct-trenching or pull-through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756039482,"sku":"TUF-URD-250","price":313.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756072250,"sku":"TUF-URD-500","price":623.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756105018,"sku":"TUF-URD-1K","price":1239.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756137786,"sku":"TUF-URD-FT","price":1.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/tufts-3-0-awg-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591842"},{"product_id":"beloit-4-0-aluminum-direct-burial-wire-urd","title":"4\/0 Aluminum Direct Burial Wire, Beloit URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 4\/0 Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThis cable is the industry standard for secondary underground power feeds where independent phase management is required. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eVersatile Installation:\u003c\/b\u003e Optimized for direct-trench or conduit\/duct applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 4\/0 URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 4\/0 URD Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.696 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 290 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 225 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQBA\" data-processed=\"true\"\u003e\n\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eAgricultural and Irrigation Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding power to farm equipment and irrigation systems, where its moisture resistance is beneficial.\u003c\/span\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756170554,"sku":"BEL-URD-250","price":370.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756203322,"sku":"BEL-URD-500","price":735.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756236090,"sku":"BEL-URD-1K","price":1463.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756268858,"sku":"BEL-URD-FT","price":1.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/beloit-4-0-awg-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591721"},{"product_id":"hofstra-250-mcm-aluminum-direct-burial-wire-urd","title":"250 MCM Aluminum Direct Burial Wire, Hofstra URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 250 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 250 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 250 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.774 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 320 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 250 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756301626,"sku":"HOF-URD-250","price":441.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756334394,"sku":"HOF-URD-500","price":878.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756367162,"sku":"HOF-URD-1K","price":1746.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756399930,"sku":"HOF-URD-FT","price":1.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/hofstra-250-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591611"},{"product_id":"gonzaga-300-mcm-aluminum-direct-burial-wire-urd","title":"300 MCM Aluminum Direct Burial Wire, Gonzaga URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 300 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 300 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 300 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.829 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 355 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 280 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756432698,"sku":"GON-URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756465466,"sku":"GON-URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756498234,"sku":"GON-URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756531002,"sku":"GON-URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/gonzaga-300-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591481"},{"product_id":"rutgers-350-mcm-aluminum-direct-burial-wire-urd","title":"350 MCM Aluminum Direct Burial Wire, Rutgers URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 350 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 350 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 350 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.880 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 385 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 305 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756563770,"sku":"RUT-URD-250","price":646.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756596538,"sku":"RUT-URD-500","price":1284.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756629306,"sku":"RUT-URD-1K","price":2555.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756662074,"sku":"RUT-URD-FT","price":2.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/rutgers-350-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591343"},{"product_id":"dartmouth-400-mcm-aluminum-direct-burial-wire-urd","title":"400 MCM Aluminum Direct Burial Wire, Dartmouth URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 400 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 400 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 400 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 0.930 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 410 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 325 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756956986,"sku":"DAR-URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756989754,"sku":"DAR-URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757022522,"sku":"DAR-URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757055290,"sku":"DAR-URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Harvard_1_0_Single_Conductor_Aluminum_URD_B_ed26b391-1dd3-4390-a59b-ac1429420367.jpg?v=1760026619"},{"product_id":"emory-500-mcm-aluminum-direct-burial-wire-urd","title":"500 MCM Aluminum Direct Burial Wire, Emory URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 500 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 500 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 500 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 1.012 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 465 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 370 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756825914,"sku":"EMO-URD-250","price":862.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756858682,"sku":"EMO-URD-500","price":1715.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756891450,"sku":"EMO-URD-1K","price":3413.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756924218,"sku":"EMO-URD-FT","price":3.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/emory-500-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775591115"},{"product_id":"duke-600-mcm-aluminum-direct-burial-wire-urd","title":"600 MCM Aluminum Direct Burial Wire, Duke URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 600 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 600 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 600 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 1.124 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 510 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 410 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981756694842,"sku":"DUK-URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981756727610,"sku":"DUK-URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981756760378,"sku":"DUK-URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981756793146,"sku":"DUK-URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/duke-600-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775590953"},{"product_id":"furman-700-mcm-aluminum-direct-burial-wire-urd","title":"700 MCM Aluminum Direct Burial Wire, Furman URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy 700 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 700 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 700 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 1.195 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 550 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 440 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757481274,"sku":"FUR-URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757514042,"sku":"FUR-URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757546810,"sku":"FUR-URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757579578,"sku":"FUR-URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/furman-700-mcm-aluminum-urd-600v-direct-burial-secondary-distribution.jpg?v=1775590720"},{"product_id":"sewanee-750-mcm-aluminum-direct-burial-wire-urd","title":"750 Aluminum Direct Burial Wire, Sewanee URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Choose 750 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 750 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eConductor Size:\u003c\/b\u003e 750 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eOverall Diameter:\u003c\/b\u003e 1.229 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 580 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 470 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"KsbFXc U6u95\"\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAQ\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAg\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQAw\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli data-processed=\"true\" data-hveid=\"CAMQBA\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"Z1qcYe\"\u003e\n\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003cstrong data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" class=\"Yjhzub\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12,0,0\" style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e\u003c\/b\u003e\u003cspan data-processed=\"true\" data-sfc-cb=\"\" data-sfc-root=\"c\" data-sfc-cp=\"\" class=\"T286Pc\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cbr\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757350202,"sku":"SEW-URD-250","price":1335.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757382970,"sku":"SEW-URD-500","price":2656.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757415738,"sku":"SEW-URD-1K","price":5285.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757448506,"sku":"SEW-URD-FT","price":5.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Harvard_1_0_Single_Conductor_Aluminum_URD_B_ab8dddfd-e653-4022-9616-3ac247db9dd4.jpg?v=1760026619"},{"product_id":"fordham-1000-mcm-aluminum-direct-burial-wire-urd","title":"1000 MCM Aluminum Direct Burial Wire, Fordham URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this single-conductor URD cable is built for performance. Featuring sunlight-resistant XLP insulation, it is rated for both direct burial and duct installations, providing a reliable, long-term solution for underground utility and sub-panel feeds.\"\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy 1000 MCM Aluminum URD?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the industry standard for high-amperage secondary underground power feeds. Its 1350-H19 aluminum construction and XLP insulation ensure maximum durability against moisture and environmental stress.\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003e600V Power Rating:\u003c\/b\u003e Consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eDirect Burial Rated:\u003c\/b\u003e Specifically designed to be buried directly in the earth without protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSunlight Resistant:\u003c\/b\u003e XLP insulation prevents UV-driven degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Optimized for large residential services and commercial loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: 1000 MCM URD Aluminum Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 1000 MCM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eInsulation:\u003c\/b\u003e Black Sunlight-Resistant XLP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eOverall Diameter:\u003c\/b\u003e 1.383 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 670 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-path-to-node=\"10,6,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 545 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-path-to-node=\"10,7,0\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692, RUS Accepted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon Applications\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul class=\"KsbFXc U6u95\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQAA\" data-processed=\"true\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eSecondary Underground Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for delivering power from pad-mounted transformers to the service entry or meter of a structure.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQAQ\" data-processed=\"true\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eResidential \u0026amp; Commercial Projects:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in residential subdivisions, manufactured home communities, and small commercial buildings.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQAg\" data-processed=\"true\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eDirect Burial or Conduit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for direct burial in the earth or installation in underground ducts.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQAw\" data-processed=\"true\"\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eRenewable Energy Sites:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for connecting solar panel arrays and wind turbines.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"Z1qcYe\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-hveid=\"CAMQBA\" data-processed=\"true\"\u003e\n\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cstrong class=\"Yjhzub\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003eIndustrial Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed in utility grids, underground vaults, and power distribution panels\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\" data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\u003cspan class=\"T286Pc\" data-sfc-cp=\"\" data-sfc-root=\"c\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003c\/h3\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757219130,"sku":"FOR-URD-250","price":1700.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757251898,"sku":"FOR-URD-500","price":3381.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757284666,"sku":"FOR-URD-1K","price":6728.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757317434,"sku":"FOR-URD-FT","price":6.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Harvard-1-0-Single-Conductor-Aluminum-URD.jpg?v=1775590082"},{"product_id":"bard-8-gauge-duplex-aluminum-direct-burial-wire-urd","title":"8-8 Duplex Aluminum Direct Burial Cable, Bard URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this #8-8 Duplex URD cable (Bard) is built for high-performance underground use. Featuring sunlight-resistant XLPE insulation on the phase conductor and a bare neutral, it is rated for both direct burial and duct installations. It provides a rugged, long-term solution for municipal street lighting and residential sub-feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose #8 Aluminum Duplex URD ?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis cable is the professional standard for 120V secondary underground power. Its \u003cb data-index-in-node=\"82\" data-path-to-node=\"6\"\u003e1350-H19 Series Aluminum Alloy\u003c\/b\u003e construction and XLP insulation provide a lightweight, corrosion-resistant alternative to copper that is significantly more cost-effective for long trench runs.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Delivers consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Engineered to be buried directly in the earth without the need for expensive conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e The black XLP insulation is UV-stabilized to prevent degradation where the cable is exposed above ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eStreamlined Installation:\u003c\/b\u003e The Duplex \"Bard\" configuration is optimized for single-phase 120V circuits, reducing material waste and installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: #8-8 Duplex URD \u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eCode Name:\u003c\/b\u003e Bard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eConductor Size:\u003c\/b\u003e #8 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Stranded 1350-H19 Aluminum Alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConfiguration:\u003c\/b\u003e Duplex (1 Insulated Phase, 1 Neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eOverall Diameter:\u003c\/b\u003e \u003cspan\u003e0.52 inches (13.208 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 70 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 55 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,9,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0,0\"\u003eStreet and Highway Lighting:\u003c\/b\u003e The go-to cable for municipal lighting and highway safety illumination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,1,0\"\u003eResidential Outbuildings:\u003c\/b\u003e Perfect for running 120V power to detached sheds, garages, and pool pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,2,0\"\u003eSecurity \u0026amp; Gates:\u003c\/b\u003e Used to power automated gate motors and remote security camera poles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,3,0\"\u003eAgricultural Systems:\u003c\/b\u003e Ideal for powering low-draw irrigation controllers and livestock waterers in moist environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757088058,"sku":"BAR-2URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757120826,"sku":"BAR-2URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757153594,"sku":"BAR-2URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757186362,"sku":"BAR-2URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Delgado_4-4_AWG_Duplex_Aluminum_URD_A_8dc58861-5de8-4794-8efd-4cff44e77818.jpg?v=1760026619"},{"product_id":"claflin-6-gauge-duplex-aluminum-direct-burial-wire-urd","title":"6-6 Duplex Aluminum Direct Burial Cable, Claflin URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this #6-6 Duplex URD cable (Claflin) is built for high-performance underground use. Featuring sunlight-resistant XLPE insulation on the phase and neutral conductor, it is rated for both direct burial and duct installations. It provides a rugged, long-term solution for municipal street lighting and residential sub-feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose #6 AWG Aluminum Duplex URD Cable?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eThis cable is the professional standard for 120V secondary underground power. Its \u003cmeta charset=\"utf-8\"\u003e\u003cb data-index-in-node=\"82\" data-path-to-node=\"6\"\u003e1350-H19\u003c\/b\u003e\u003cb data-index-in-node=\"82\" data-path-to-node=\"6\"\u003e Series Aluminum Alloy\u003c\/b\u003e construction and XLP insulation provide a lightweight, corrosion-resistant alternative to copper that is significantly more cost-effective for long trench runs.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Delivers consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Engineered to be buried directly in the earth without the need for expensive conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e The black XLP insulation is UV-stabilized to prevent degradation where the cable is exposed above ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eStreamlined Installation:\u003c\/b\u003e The Duplex configuration is optimized for single-phase 120V circuits, reducing material waste and installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8\"\u003eTechnical Specifications: #6-6 Duplex URD Cable\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eCode Name:\u003c\/b\u003e Claflin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eConductor Size:\u003c\/b\u003e #6 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,9,0\"\u003eConductor Material:\u003c\/b\u003e Stranded 1350-H19 Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConfiguration:\u003c\/b\u003e Duplex (1 Insulated Phase, 1 Neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eOverall Diameter:\u003c\/b\u003e \u003cspan\u003e0.60 inches (15.24 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 95 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 70 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,9,0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eHigh-Output Municipal Lighting:\u003c\/b\u003e Used for major roadway lighting and highway interchanges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eWorkshop \u0026amp; Garage Sub-Panels:\u003c\/b\u003e Ideal for running a 60-amp sub-feed to a remote structure via underground duct.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eIrrigation Pumps:\u003c\/b\u003e Providing power to heavy-duty farm irrigation timers and water pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eEV Charging (Level 1):\u003c\/b\u003e Suitable for dedicated 120V circuits to remote vehicle charging stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757743418,"sku":"CLA-2URD-250","price":217.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757776186,"sku":"CLA-2URD-500","price":432.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757808954,"sku":"CLA-2URD-1K","price":858.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757841722,"sku":"CLA-2URD-FT","price":0.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Delgado_4-4_AWG_Duplex_Aluminum_URD_A_141b317d-b4aa-4460-8a06-28d903a07a49.jpg?v=1760026619"},{"product_id":"delgado-4-gauge-duplex-aluminum-direct-burial-wire-urd","title":"4-4 Duplex Aluminum Direct Burial Cable, Delgado URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this #4 AWG Duplex URD cable (Delgado) is built for rugged underground performance. Featuring one insulated phase conductor and one neutral, it uses sunlight-resistant XLPE insulation and is rated for both direct burial and duct installations. Built with 1350-H19 Series Aluminum, it provides a high-strength, cost-effective solution for heavy-duty outdoor lighting and residential sub-panel feeds.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose #4 Aluminum Duplex URD Cable?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003e\u003cmeta charset=\"utf-8\"\u003eThis cable is the professional standard for 120V secondary underground power. Its \u003cb data-path-to-node=\"6\" data-index-in-node=\"82\"\u003e1350-H19 Series Aluminum Alloy\u003c\/b\u003e construction and XLP insulation provide a lightweight, corrosion-resistant alternative to copper that is significantly more cost-effective for long trench runs.\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e600V Power Rating:\u003c\/b\u003e Delivers consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003eDirect Burial Rated:\u003c\/b\u003e Engineered to be buried directly in the earth without the need for expensive conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003eSunlight Resistant:\u003c\/b\u003e The black XLP insulation is UV-stabilized to prevent degradation where the cable is exposed above ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eStreamlined Installation:\u003c\/b\u003e The Duplex \"configuration is optimized for single-phase 120V circuits, reducing material waste and installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: #4-4 Duplex URD Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eCode Name:\u003c\/b\u003e Delgado\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e #4 AWG\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Stranded 1350-H19 Aluminum Alloy\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Duplex (1 Insulated Phase, 1 Neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eOverall Diameter (OD):\u003c\/b\u003e \u003cspan\u003e0.69 inches (17.526 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 125 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 90 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e 1350-H19 Aluminum Alloy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eHigh-Output Municipal Lighting:\u003c\/b\u003e The standard for major highway illumination and large parking lot lighting circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eWorkshop \u0026amp; Large Outbuildings:\u003c\/b\u003e Ideal for running a high-amperage 120V sub-feed to remote garages, workshops, or barn equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eEV Charging (Level 1):\u003c\/b\u003e Provides a robust dedicated circuit for remote vehicle charging stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eAgricultural Power:\u003c\/b\u003e Powering heavy-duty irrigation pumps and automated feeding systems in wet or damp soil conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757612346,"sku":"DEL-2URD-250","price":254.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757645114,"sku":"DEL-2URD-500","price":505.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757677882,"sku":"DEL-2URD-1K","price":1005.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757710650,"sku":"DEL-2URD-FT","price":1.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Delgado_4-4_AWG_Duplex_Aluminum_URD_A_eb225b32-c241-4393-9064-ff70f32b1bfe.jpg?v=1760026618"},{"product_id":"everett-2-gauge-duplex-aluminum-direct-burial-wire-urd","title":"2-2 Duplex Aluminum Direct Burial Cable, Everett URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"Designed for 600V secondary power distribution, this #2-2 Duplex URD cable (Everett) is the \"Heavy-Duty\" choice for 120V underground applications. Featuring one insulated phase conductor and one neutral, it utilizes sunlight-resistant XLPE (Cross-Linked Polyethylene) insulation and is rated for both direct burial and duct installations. Built with 1350-H19 Series Aluminum, it offers superior mechanical strength and high ampacity for demanding residential and municipal projects.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose #2 Aluminum Duplex URD Cable?\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003e#2 AWG\u003c\/b\u003e size provides the maximum current capacity in a standard duplex configuration. Its 1350-H19 series aluminum construction is specifically chosen to withstand the high tension of long pulls through underground conduit or rocky trenches.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e600V Power Rating:\u003c\/b\u003e Delivers consistent performance in wet or dry locations up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDirect Burial Rated:\u003c\/b\u003e Engineered to be buried directly in the earth without the need for expensive conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSunlight Resistant:\u003c\/b\u003e The black XLP insulation is UV-stabilized to prevent degradation where the cable is exposed above ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eStreamlined Installation:\u003c\/b\u003e The Duplex configuration is optimized for single-phase 120V circuits, reducing material waste and installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: #2-2 Duplex URD Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eCode Name:\u003c\/b\u003e Everett\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e #2 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Stranded 1350-H19 Aluminum Alloy\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConfiguration:\u003c\/b\u003e Duplex (1 Insulated Phase, 1 Neutral)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eMax Temp:\u003c\/b\u003e 90°C (Wet\/Dry)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eOverall Diameter (OD):\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e0.80 inches (20.32 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 165 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 120 Amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eStandards:\u003c\/b\u003e UL 854 (Type USE-2), ASTM B230, B231, B901, ICEA S-105-692\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"10\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003ePrimary Municipal Lighting:\u003c\/b\u003e Used for major highway interchanges and large-scale public infrastructure lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eHigh-Amperage Sub-Feeds:\u003c\/b\u003e Ideal for powering large remote workshops, welding shops, or residential outbuildings with heavy electrical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eIrrigation \u0026amp; Water Systems:\u003c\/b\u003e The preferred cable for high-draw agricultural water pumps and large-scale center-pivot irrigation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eUtility Secondary Services:\u003c\/b\u003e Used by utility companies for high-capacity 120V secondary distribution drops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e*All values are nominal and subject to correction. *Ampacity: for 3 cables triplexed, 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981757874490,"sku":"EVE-2URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981757907258,"sku":"EVE-2URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981757940026,"sku":"EVE-2URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981757972794,"sku":"EVE-2URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Delgado_4-4_AWG_Duplex_Aluminum_URD_A_12c759c0-7e4e-41e3-98f8-7129a6401659.jpg?v=1760026614"},{"product_id":"erskine-6-6-6-gauge-triplex-aluminum-direct-burial-wire-urd","title":"6-6-6 Triplex Aluminum Direct Burial Cable, Erskine URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\u003cbr\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Professionals Choose Erskine 6-6-6 Triplex URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"4\"\u003e6-6-6 Erskine Aluminum URD\u003c\/b\u003e cable is the benchmark for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant cross-linked polyethylene (XLP) insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eTechnical Specifications: Erskine 6-6-6 URD\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 0.64 inches (16.26 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 95 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 70 Amps.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003eUL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 6-6-6 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eResidential Service Entrances:\u003c\/b\u003e Standard power feed for new home construction and service upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eUnderground Secondary Distribution:\u003c\/b\u003e Reliable power delivery from utility-side transformers to residential loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eFarm \u0026amp; Light Commercial:\u003c\/b\u003e Proven performance for sub-panel feeds, outbuilding power, and small-scale commercial site lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981758038330,"sku":"ERS-3URD-250","price":294.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758071098,"sku":"ERS-3URD-500","price":584.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758103866,"sku":"ERS-3URD-1K","price":1161.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758136634,"sku":"ERS-3URD-FT","price":1.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_1c95f9fa-65b3-43d0-b22f-4b560091104c.jpg?v=1760026614"},{"product_id":"vassar-4-4-4-triplex-aluminum-direct-burial-wire-urd","title":"4-4-4 Triplex Aluminum Direct Burial Cable, Vassar URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose Vassar 4-4-4 Aluminum Triplex URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"4\"\u003e4-4-4 Vassar URD\u003c\/b\u003e cable is a premium solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant cross-linked polyethylene (XLP) insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eTechnical Specifications: Vassar 4-4-4 URD Cable\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 4-4-4 AWG Aluminum Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 0.75 inches (19.05 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 125 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 90 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCommon 4-4-4 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eResidential Service Entrances:\u003c\/b\u003e Standard power feed for new home construction and service upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eUnderground Secondary Distribution:\u003c\/b\u003e Reliable power delivery from utility-side transformers to residential loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eFarm \u0026amp; Light Commercial:\u003c\/b\u003e Proven performance for sub-panel feeds, outbuilding power, and small-scale commercial site lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c\/sup\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758660922,"sku":"VAS-3URD-100","price":139.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981758693690,"sku":"VAS-3URD-250","price":343.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758726458,"sku":"VAS-3URD-500","price":682.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758759226,"sku":"VAS-3URD-1K","price":1356.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758791994,"sku":"VAS-3URD-FT","price":1.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_c2fe7bde-5100-4181-9a9d-4dbfddeb1beb.jpg?v=1760026614"},{"product_id":"stephens-2-2-4-triplex-aluminum-direct-burial-wire-urd","title":"2-2-4 Triplex Aluminum Direct Burial Cable, Stephens URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose Stephens 2-2-4 Aluminum Triplex Cable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-index-in-node=\"4\" data-path-to-node=\"7\"\u003e2-2-4 Stephens URD\u003c\/b\u003e cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant cross-linked polyethylene (XLP) insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eTechnical Specifications: Stephens 2-2-4 URD Cable\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10\"\u003eENGINEERING OVERVIEW: 2-2-4 AWG Aluminum Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0,0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e 0.87 inches (22.098 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 165 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 120 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eCommon 2-2-4 URD Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,0,0\"\u003eResidential Service Entrances:\u003c\/b\u003e Standard power feed for new home construction and service upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,1,0\"\u003eUnderground Secondary Distribution:\u003c\/b\u003e Reliable power delivery from utility-side transformers to residential loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,2,0\"\u003eFarm \u0026amp; Light Commercial:\u003c\/b\u003e Proven performance for sub-panel feeds, outbuilding power, and small-scale commercial site lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758333242,"sku":"STV-3URD-100","price":174.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981758366010,"sku":"STV-3URD-250","price":429.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758398778,"sku":"STV-3URD-500","price":853.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758431546,"sku":"STV-3URD-1K","price":1697.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758464314,"sku":"STV-3URD-FT","price":1.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_3b10c23a-0d56-40b3-bfbc-b373e76631ae.jpg?v=1760026614"},{"product_id":"ramapo-2-2-2-triplex-aluminum-direct-burial-wire-urd","title":"2-2-2 Triplex Aluminum Direct Burial Cable, Ramapo URD","description":"\u003cp data-path-to-node=\"5\"\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose Ramapo 2-2-2 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe \u003cb data-path-to-node=\"7\" data-index-in-node=\"4\"\u003e2-2-2 Ramapo URD\u003c\/b\u003e cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant cross-linked polyethylene (XLP) insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: Ramapo 2-2-2 URD Direct Burial Cable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 2-2-2 AWG Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 0.87 inches (22.098 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 165 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 120 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eCommon 2-2-2 URD Applications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eResidential Service Entrances:\u003c\/b\u003e Standard power feed for new home construction and service upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eUnderground Secondary Distribution:\u003c\/b\u003e Reliable power delivery from utility-side transformers to residential loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eFarm \u0026amp; Light Commercial:\u003c\/b\u003e Proven performance for sub-panel feeds, outbuilding power, and small-scale commercial site lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759807802,"sku":"RAM-3URD-100","price":175.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759840570,"sku":"RAM-3URD-250","price":431.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759873338,"sku":"RAM-3URD-500","price":858.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759906106,"sku":"RAM-3URD-1K","price":1707.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759938874,"sku":"RAM-3URD-FT","price":1.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_67a2fdb4-b52c-4a68-acb8-6332aca45985.jpg?v=1760026614"},{"product_id":"brenau-1-0-1-0-2-triplex-aluminum-direct-burial-wire-urd","title":"1\/0-1\/0-2 Triplex Aluminum Direct Burial Cable, Brenau URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose Brenau 1\/0-1\/0-2 Triplex URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eOur \u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003e1\/0-1\/0-2 Brenau Aluminum URD\u003c\/b\u003e cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant cross-linked polyethylene (XLP) insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: Brenau 1\/0-1\/0-2 URD Aluminum Cable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 1\/0-1\/0-2 AWG Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-path-to-node=\"10,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-path-to-node=\"10,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-path-to-node=\"10,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 1.11 inches (28.194 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,8,0\"\u003e\u003cb data-path-to-node=\"10,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 215 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,9,0\"\u003e\u003cb data-path-to-node=\"10,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 160 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,10,0\"\u003e\u003cb data-path-to-node=\"10,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 1\/0-1\/0-2 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003eResidential Service Entrances:\u003c\/b\u003e Standard power feed for new home construction and service upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eUnderground Secondary Distribution:\u003c\/b\u003e Reliable power delivery from utility-side transformers to residential loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eFarm \u0026amp; Light Commercial:\u003c\/b\u003e Proven performance for sub-panel feeds, outbuilding power, and small-scale commercial site lighting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758169402,"sku":"BRE-3URD-100","price":211.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981758202170,"sku":"BRE-3URD-250","price":520.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758234938,"sku":"BRE-3URD-500","price":1034.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758267706,"sku":"BRE-3URD-1K","price":2058.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758300474,"sku":"BRE-3URD-FT","price":2.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_be90d94c-a2aa-4718-abee-16e2bc7697e7.jpg?v=1760026614"},{"product_id":"bergen-1-0-1-0-1-0-triplex-aluminum-direct-burial-wire-urd","title":"1\/0-1\/0-1\/0 Triplex Aluminum Direct Burial Cable, Bergen URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eConcentric stranded or compressed 1350-H19 series aluminum conductor.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e1\/0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e160 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758988602,"sku":"BER-3URD-100","price":230.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759021370,"sku":"BER-3URD-250","price":567.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759054138,"sku":"BER-3URD-500","price":1127.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759086906,"sku":"BER-3URD-1K","price":2243.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759119674,"sku":"BER-3URD-FT","price":2.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_3371d668-0657-4515-9000-7730c74cc066.jpg?v=1760026618"},{"product_id":"hunter-2-0-2-0-2-0-triplex-aluminum-direct-burial-wire-urd","title":"2\/0-2\/0-2\/0 Triplex Aluminum Direct Burial Cable, Hunter URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose \u003cmeta charset=\"utf-8\"\u003eConverse 2\/0-2\/0-2\/0 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 2\/0-2\/0-2\/0 Hunter URD cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eRated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eFor faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: \u003cmeta charset=\"utf-8\"\u003eConverse 2\/0-2\/0-2\/0 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: \u003cmeta charset=\"utf-8\"\u003e2\/0-2\/0-2\/0 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSecondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eConcentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1.20 inches (30.48 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e\u003cspan\u003e 245\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e\u003cspan\u003e 180\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCommon \u003cmeta charset=\"utf-8\"\u003e2\/0-2\/0-2\/0 URD Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eService Entrance Conductors:\u003c\/b\u003e Primary power feed from the transformer to the main distribution panel of a residential building.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0\"\u003eService Upgrades:\u003c\/b\u003e Ideal for replacing older, undersized service conductors to support increased modern electrical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eBranch Circuit Feeders:\u003c\/b\u003e High-amperage power transmission to secondary distribution hubs, outbuildings, or detached garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0\"\u003eCommercial Site Development:\u003c\/b\u003e Reliable power delivery for small-to-medium business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760135482,"sku":"HUN-3URD-100","price":264.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760168250,"sku":"HUN-3URD-250","price":651.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760201018,"sku":"HUN-3URD-500","price":1294.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760233786,"sku":"HUN-3URD-1K","price":2574.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760266554,"sku":"HUN-3URD-FT","price":2.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_c48b8635-1e6d-4f8f-98af-9777f5e09d00.jpg?v=1760026619"},{"product_id":"converse-2-0-2-0-1-triplex-aluminum-direct-burial-wire-urd","title":"2\/0-2\/0-1 Triplex Aluminum Direct Burial Cable, Converse URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose \u003cmeta charset=\"utf-8\"\u003eConverse 2\/0-2\/0-1 Triplex\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe 2\/0-2\/0-1 Converse URD cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eRated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eFor faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: \u003cmeta charset=\"utf-8\"\u003eConverse 2\/0-2\/0-1 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: \u003cmeta charset=\"utf-8\"\u003e2\/0-2\/0-1 AWG Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSecondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eConcentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1.20 in. (30.48 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e\u003cspan\u003e 245\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e\u003cspan\u003e 180\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCommon \u003cmeta charset=\"utf-8\"\u003e2\/0-2\/0-1 URD Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eService Entrance Conductors:\u003c\/b\u003e Primary power feed from the transformer to the main distribution panel of a residential building.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0\"\u003eService Upgrades:\u003c\/b\u003e Ideal for replacing older, undersized service conductors to support increased modern electrical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eBranch Circuit Feeders:\u003c\/b\u003e High-amperage power transmission to secondary distribution hubs, outbuildings, or detached garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0\"\u003eCommercial Site Development:\u003c\/b\u003e Reliable power delivery for small-to-medium business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759643962,"sku":"CON-3URD-100","price":250.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759676730,"sku":"CON-3URD-250","price":616.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759709498,"sku":"CON-3URD-500","price":1225.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759742266,"sku":"CON-3URD-1K","price":2438.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759775034,"sku":"CON-3URD-FT","price":2.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_e6124b4a-0f21-4cc0-b528-cf11dae594da.jpg?v=1760026618"},{"product_id":"hollins-3-0-3-0-1-0-triplex-aluminum-direct-burial-wire-urd","title":"3\/0-3\/0-1\/0 Triplex Aluminum Direct Burial Cable, Hollins URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The industry-standard for residential, farm, and light commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e3\/0-3\/0-1\/0 Triplex URD\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eThe 3\/0-3\/0-1\/0 Hollins URD cable is a heavy-duty solution for secondary underground residential power distribution. Engineered to meet the rugged demands of direct burial, it provides a stable, long-term solution for moving power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation and moisture ingress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eRated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, ensuring durability at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eFor faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications:\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan\u003e3\/0-3\/0-1\/0 Triplex URD\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW:\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cstrong\u003e3\/0-3\/0-1\/0 Aluminum Hollins\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSecondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eConcentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1.30 inches (33.02 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e\u003cspan\u003e 280\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e\u003cspan\u003e 205\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCommon\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan\u003e3\/0-3\/0-1\/0 Triplex URD Applications\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eService Entrance Conductors:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ePrimary power feed from the transformer to the main distribution panel of a residential building.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0\"\u003eService Upgrades:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for replacing older, undersized service conductors to support increased modern electrical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eBranch Circuit Feeders:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eHigh-amperage power transmission to secondary distribution hubs, outbuildings, or detached garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0\"\u003eCommercial Site Development:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eReliable power delivery for small-to-medium business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eVersatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759316282,"sku":"HOL-3URD-100","price":302.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759349050,"sku":"HOL-3URD-250","price":744.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759381818,"sku":"HOL-3URD-500","price":1480.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759414586,"sku":"HOL-3URD-1K","price":2945.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759447354,"sku":"HOL-3URD-FT","price":3.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_10479f4f-c240-4829-8301-cb7cb690738c.jpg?v=1760026618"},{"product_id":"rockland-3-0-3-0-3-0-triplex-aluminum-direct-burial-wire-urd","title":"3\/0-3\/0-3\/0 Triplex Aluminum Direct Burial Cable, Rockland URD","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cstrong\u003e\"The Rockland 3\/0-3\/0-3\/0 triplex URD cable is engineered for heavy-duty secondary power distribution. Built to withstand the harshest underground conditions, this cable features high-conductivity 1350-H19 aluminum and robust, sunlight-resistant XLP insulation, making it the ideal choice for high-amperage residential and commercial service entrances.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eWhy Electricians Choose Rockland 3\/0-3\/0-3\/0 Triplex\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003eFor projects requiring high current capacity and long-term reliability, the Rockland triplex URD is an excellent option. This configuration provides superior power delivery for demanding electrical loads while offering the installation flexibility required for complex underground routing.\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced XLP insulation provides exceptional resistance to UV degradation and environmental aging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically formulated to resist moisture and soil-based stressors without the need for additional protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eHigh-Capacity Feed:\u003c\/b\u003e Designed to support the increased electrical demands of modern residential and commercial builds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: Rockland 3\/0-3\/0-3\/0 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10\"\u003eENGINEERING OVERVIEW: 3\/0-3\/0-3\/0 AWG Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,0,0\"\u003eApplication:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eSecondary underground distribution circuits; transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,1,0\"\u003eVoltage Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,2,0\"\u003eUL Listing:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,3,0\"\u003eConductor Material:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eConcentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,4,0\"\u003ePhase Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eBlack XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,6,0\"\u003eTemperature Rating:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e1.30 inches (33.02 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e\u003cspan\u003e 280\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e\u003cspan\u003e 205\u003c\/span\u003e Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11,10,0\"\u003eCompliance Standards:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eUL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"13\"\u003eCommon Rockland 3\/0-3\/0-3\/0 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,0,0\"\u003e\u003cb data-path-to-node=\"14,0,0\" data-index-in-node=\"0\"\u003eService Entrance Conductors:\u003c\/b\u003e Primary power feed from the transformer to the main distribution panel of high-demand buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,1,0\"\u003e\u003cb data-path-to-node=\"14,1,0\" data-index-in-node=\"0\"\u003eService Upgrades:\u003c\/b\u003e Ideal for replacing aging infrastructure to support increased electrical loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,2,0\"\u003e\u003cb data-path-to-node=\"14,2,0\" data-index-in-node=\"0\"\u003eBranch Circuit Feeders:\u003c\/b\u003e High-amperage power transmission to secondary distribution hubs and multi-unit developments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e\u003cb data-path-to-node=\"14,3,0\" data-index-in-node=\"0\"\u003eCommercial Site Development:\u003c\/b\u003e Reliable power delivery for business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"14,4,0\"\u003e\u003cb data-path-to-node=\"14,4,0\" data-index-in-node=\"0\"\u003eDirect-Trench \u0026amp; Conduit Installations:\u003c\/b\u003e Flexible for both open-trench burial and pull-through electrical duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"24\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759480122,"sku":"ROC-3URD-100","price":0.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759512890,"sku":"ROC-3URD-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759545658,"sku":"ROC-3URD-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759578426,"sku":"ROC-3URD-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759611194,"sku":"ROC-3URD-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_53da0142-6bb8-4497-b15a-32259806607a.jpg?v=1760026618"},{"product_id":"monmouth-4-0-4-0-4-0-triplex-aluminum-direct-burial-wire-urd","title":"4\/0-4\/0-4\/0 Triplex Aluminum Direct Burial Cable, Monmouth URD","description":"\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"3\"\u003e\u003cstrong\u003eWhy Engineers Choose Monmouth 4\/0-4\/0-4\/0 Triplex Aluminum URD\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe Monmouth 4\/0-4\/0-4\/0 URD cable is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\u003cstrong\u003eTechnical Specifications: Monmouth 4\/0-4\/0-4\/0 URD\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7\"\u003eENGINEERING OVERVIEW: 4\/0-4\/0-4\/0 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,0,0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e1.42 inches (36.068 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 315 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 240 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"8,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003e\u003cstrong\u003eCommon 4\/0-4\/0-4\/0 URD Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring high capacity to support modern, high-load electrical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as workshops, agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for medium-to-large business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs in large-scale infrastructure projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eAmpacity:\u003c\/b\u003e 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759152442,"sku":"MON-3URD-100","price":382.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981759185210,"sku":"MON-3URD-250","price":941.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981759217978,"sku":"MON-3URD-500","price":1872.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981759250746,"sku":"MON-3URD-1K","price":3725.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981759283514,"sku":"MON-3URD-FT","price":3.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_435a9160-5ee0-4668-8559-b4189ec1c9b2.jpg?v=1760026618"},{"product_id":"sweetbriar-4-0-4-0-2-0-triplex-aluminum-direct-burial-wire-urd","title":"4\/0-4\/0-2\/0 Triplex Aluminum Direct Burial Cable, Sweetbriar URD","description":"\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"3\"\u003e\u003cstrong\u003eWhy Electricians Choose Sweetbriar 4\/0-4\/0-2\/0 Triplex Aluminum URD\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe Sweetbriar 4\/0-4\/0-2\/0 URD cable is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\u003cstrong\u003eTechnical Specifications: Sweetbriar 4\/0-4\/0-2\/0 URD\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 4\/0-4\/0-2\/0 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e1.42 inches (36.068 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003e\u003cb data-path-to-node=\"8,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 315 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,9,0\"\u003e\u003cb data-path-to-node=\"8,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 240 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,10,0\"\u003e\u003cb data-path-to-node=\"8,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003e\u003cstrong\u003eCommon 4\/0-4\/0-2\/0 URD Applications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring 300A+ capacity to support modern, high-load electrical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as workshops, agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for medium-to-large business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs in large-scale infrastructure projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981759971642,"sku":"SWT-3URD-100","price":344.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760004410,"sku":"SWT-3URD-250","price":848.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760037178,"sku":"SWT-3URD-500","price":1686.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760069946,"sku":"SWT-3URD-1K","price":3354.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760102714,"sku":"SWT-3URD-FT","price":3.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_d482712a-4663-45fa-9a0a-45b33da51df2.jpg?v=1760026618"},{"product_id":"pratt-250-250-3-0-triplex-aluminum-direct-burial-wire-urd","title":"250-250-3\/0 Triplex Aluminum Direct Burial Cable, Pratt URD","description":"\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"3\"\u003e\u003cstrong\u003eWhy Electricians Choose Pratt 250-250-3\/0 Triplex Aluminum URD\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe Pratt 250-250-3\/0 URD cable is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003e\n\u003cstrong\u003eTechnical Specifications: Pratt \u003c\/strong\u003e\u003cstrong\u003e250-250-3\/0 \u003c\/strong\u003e\u003cstrong style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eURD\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 250-250-3\/0 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,5,0\"\u003e\u003cb data-path-to-node=\"8,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,6,0\"\u003e\u003cb data-path-to-node=\"8,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,7,0\"\u003e\u003cb data-path-to-node=\"8,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e \u003cspan\u003e1.62 inches (41.148 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,8,0\"\u003e\u003cb data-path-to-node=\"8,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 345 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,9,0\"\u003e\u003cb data-path-to-node=\"8,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 265 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,10,0\"\u003e\u003cb data-path-to-node=\"8,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003e\n\u003cstrong\u003eCommon \u003c\/strong\u003e\u003cstrong\u003e250-250-3\/0 \u003c\/strong\u003e\u003cstrong\u003eURD Applications\u003c\/strong\u003e\n\u003c\/h4\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring 300A+ capacity to support modern, high-load electrical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as workshops, agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for medium-to-large business infrastructure and exterior utility equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-path-to-node=\"10,4,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs in large-scale infrastructure projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-path-to-node=\"13\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758824762,"sku":"PRT-3URD-100","price":432.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981758857530,"sku":"PRT-3URD-250","price":1064.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758890298,"sku":"PRT-3URD-500","price":2117.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758923066,"sku":"PRT-3URD-1K","price":4212.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758955834,"sku":"PRT-3URD-FT","price":4.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_82ebf883-43f8-46ed-846a-c576b4c0749a.jpg?v=1760026618"},{"product_id":"wesleyan-350-350-4-0-triplex-aluminum-direct-burial-wire-urd","title":"350-350-4\/0 Triplex Aluminum Direct Burial Cable, Wesleyan URD","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eWhy Electricians Choose Wesleyan 350-350-4\/0 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe Wesleyan 350-350-4\/0 URD cable is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: Wesleyan 350-350-4\/0 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eENGINEERING OVERVIEW: 350-350-4\/0 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e 1.84 inches (\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e46.736\u003c\/span\u003e mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 415 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 320 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 350-350-4\/0 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring 400A capacity to support modern, high-load electrical systems and multi-family units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as industrial workshops, heavy agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for large-scale business infrastructure and exterior utility equipment where voltage drop is a critical concern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,4,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs in large-scale infrastructure projects.\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"13\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13\"\u003eAmpacity:\u003c\/b\u003e 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981758497082,"sku":"WES-3URD-100","price":571.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981758529850,"sku":"WES-3URD-250","price":1407.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981758562618,"sku":"WES-3URD-500","price":2798.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981758595386,"sku":"WES-3URD-1K","price":5568.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981758628154,"sku":"WES-3URD-FT","price":5.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_44558626-471d-4321-af18-cbb66ff1ec6a.jpg?v=1760026618"},{"product_id":"holyoke-500-500-300-triplex-aluminum-direct-burial-wire-urd","title":"500-500-300 Triplex Aluminum Direct Burial Cable, Holyoke URD","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eWhy Electricians Choose Holyoke 500-500-300 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe 500-500-300 Triplex Aluminum URD is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: Holyoke 500-500-300 URD Cable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eENGINEERING OVERVIEW: \u003cmeta charset=\"utf-8\"\u003e\u003c\/b\u003e\u003cstrong\u003e500-500-300 Triplex URD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e 2.12 inches (53.848 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 495 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 395 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 500-500-300 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring 400A capacity to support modern, high-load electrical systems and multi-family units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as industrial workshops, heavy agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for large-scale business infrastructure and exterior utility equipment where voltage drop is a critical concern.\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,4,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003c\/p\u003e\n\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760463162,"sku":"HOL-3URD-100","price":251.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760495930,"sku":"HOL-3URD-250","price":622.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760528698,"sku":"HOL-3URD-500","price":1243.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760561466,"sku":"HOL-3URD-1K","price":2485.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760594234,"sku":"HOL-3URD-FT","price":2.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_e4716c21-2c1d-49ff-847f-5f56c8c29e3c.jpg?v=1760026618"},{"product_id":"rider-500-500-350-triplex-aaluminum-direct-burial-wire-urd","title":"500-500-350 Triplex Aluminum Direct Burial Cable, Rider URD","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eWhy Electricians Choose \u003cmeta charset=\"utf-8\"\u003eRider 500-500-350 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe 500-500-350 Triplex Aluminum URD is the heavy-duty solution for high-capacity secondary underground power distribution. Engineered to meet the rigorous demands of demanding service upgrades and large-scale site developments, it provides a stable, high-performance solution for moving substantial power from the transformer to the service entrance. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under heavy load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: \u003cmeta charset=\"utf-8\"\u003eRider 500-500-350 URD Cable\u003c\/h4\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eENGINEERING OVERVIEW: \u003cmeta charset=\"utf-8\"\u003e\u003c\/b\u003e\u003cstrong\u003e500-500-350 Triplex URD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eApplication:\u003c\/b\u003e Secondary underground distribution circuits; high-capacity transformer-to-service-entrance power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e 2.12 inches (53.848 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 495 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 395 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 500-500-350 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eMain Service Entrance:\u003c\/b\u003e High-amperage power feed from the utility transformer to the main distribution panel for large residential or commercial buildings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eService Upgrades:\u003c\/b\u003e Essential for heavy-duty service upgrades requiring 400A capacity to support modern, high-load electrical systems and multi-family units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eSub-Panel Feeders:\u003c\/b\u003e Reliable power transmission for large secondary distribution hubs, such as industrial workshops, heavy agricultural facilities, or detached commercial garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eSite Development:\u003c\/b\u003e Robust power delivery for large-scale business infrastructure and exterior utility equipment where voltage drop is a critical concern.\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,4,0\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14,3,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Versatile enough for direct-trench installation or pull-through duct\/conduit runs.\u003c\/p\u003e\n\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760954682,"sku":"RID-3URD-100","price":834.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760987450,"sku":"RID-3URD-250","price":2054.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761020218,"sku":"RID-3URD-500","price":4087.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761052986,"sku":"RID-3URD-1K","price":8132.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761085754,"sku":"RID-3URD-FT","price":8.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_a974c0a8-f24a-4cec-b798-c4a3f8d0f33e.jpg?v=1760026619"},{"product_id":"fairfield-750-750-500-triplex-aluminum-direct-burial-wire-urd","title":"750-750-500 Triplex Aluminum Direct Burial Cable, Fairfield  URD","description":"\u003cp data-path-to-node=\"3\"\u003e\u003cstrong\u003e\"The industry-standard for high-amperage residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eWhy Electricians Choose Fairfield 750-750-500 Triplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe Fairfield 750-750-500 URD cable is the definitive high-capacity solution for major secondary underground power distribution. Engineered for the most demanding large-scale commercial developments and industrial service entrances, it provides a stable, high-performance solution for moving massive power loads. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers the highest level of resistance to environmental degradation, moisture ingress, and thermal stress in its class.\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,0,0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, ensuring stability under peak load conditions for industrial machinery and large complexes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,1,0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure, maintaining structural integrity at the service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,2,0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes and clear sequential footage markings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"6,3,0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within large-diameter conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications: Fairfield 750-750-500 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9\"\u003eENGINEERING OVERVIEW: 750-750-500 Triplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,0,0\"\u003eApplication:\u003c\/b\u003e High-capacity secondary underground distribution; industrial transformer-to-service power feeds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,1,0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,2,0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,3,0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,4,0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,5,0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,6,0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,7,0\"\u003eCable Outer Diameter:\u003c\/b\u003e \u003cspan\u003e2.40 inches (60.96 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,8,0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 620 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,9,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,9,0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 495 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,10,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"10,10,0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854 (Service-Entrance Cable); Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692; Federal Spec A-A-59544A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"12\"\u003eCommon 750-750-500 URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,0,0\"\u003eIndustrial Service Entrance:\u003c\/b\u003e The go-to feeder for manufacturing plants, data centers, and heavy industrial facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,1,0\"\u003eMajor Infrastructure Upgrades:\u003c\/b\u003e Necessary for massive power requirements where multiple smaller conductors are not feasible or code-compliant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,2,0\"\u003eUtility-Scale Solar:\u003c\/b\u003e Frequently used for main collection lines and inverter-to-transformer runs in utility-scale renewable energy projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,3,0\"\u003eMulti-Family Housing:\u003c\/b\u003e Ideal for main secondary feeders serving large apartment complexes or mixed-use developments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"13,4,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Rated for direct-trench installation or pull-through duct runs in high-demand infrastructure projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"24\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760299322,"sku":"FAR-3URD-100","price":1419.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760332090,"sku":"FAR-3URD-250","price":3495.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760364858,"sku":"FAR-3URD-500","price":6954.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760397626,"sku":"FAR-3URD-1K","price":13836.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760430394,"sku":"FAR-3URD-FT","price":14.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_c6bcccff-8c02-4d67-961d-57db154e480d.jpg?v=1760026619"},{"product_id":"4-4-4-triplex-aluminum-direct-burial-cable-vassar-8000-urd","title":"4-4-4 Triplex Aluminum Direct Burial Cable, Vassar 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e4 AWG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e85 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e125 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760627002,"sku":"VAS8K-3URD-100","price":155.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760659770,"sku":"VAS-3URD-250","price":382.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760692538,"sku":"VAS8K-3URD-500","price":760.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760725306,"sku":"VAS8K-3URD-1K","price":1512.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760758074,"sku":"VAS8K-3URD-FT","price":1.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_e22e59fa-6a40-4581-a07b-9d7175a8ad0f.jpg?v=1760026618"},{"product_id":"2-2-4-triplex-aluminum-direct-burial-cable-stephens-8000-urd","title":"2-2-4 Triplex Aluminum Direct Burial Cable, Stephens 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e4 AWG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e120 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981760790842,"sku":"STV8K-3URD-100","price":194.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981760823610,"sku":"STV8K-3URD-250","price":478.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981760856378,"sku":"STV8K-3URD-500","price":951.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981760889146,"sku":"STV8K-3URD-1K","price":1892.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981760921914,"sku":"STV8K-3URD-FT","price":1.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_8c603657-ec52-43ce-89db-232b69e84b4d.jpg?v=1760026619"},{"product_id":"2-2-2-triplex-aluminum-direct-burial-cable-ramapo-8000-urd","title":"2-2-2 Triplex Aluminum Direct Burial Cable, Ramapo 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e2 AWG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e120 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761118522,"sku":"RAM8K-3URD-100","price":194.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761151290,"sku":"RAM8K-3URD-250","price":478.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761184058,"sku":"RAM8K-3URD-500","price":951.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761216826,"sku":"RAM8K-3URD-1K","price":1892.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761249594,"sku":"RAM8K-3URD-FT","price":1.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_9e2d0ad9-b45f-4f16-b5d0-879505385615.jpg?v=1760026614"},{"product_id":"1-0-1-0-2-triplex-aluminum-direct-burial-cable-brenau-8000-urd","title":"1\/0-1\/0-2 Triplex Aluminum Direct Burial Cable, Brenau 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e2 AWG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003cbr\u003e\u003c\/strong\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation.\u003cstrong\u003e The 8000 Series is RHH, RHW-2, and USE-2 rated.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e160 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761773882,"sku":"BRE8K-3URD-100","price":235.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761806650,"sku":"BRE8K-3URD-250","price":579.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761839418,"sku":"BRE8K-3URD-500","price":1152.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761872186,"sku":"BRE8K-3URD-1K","price":2292.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761904954,"sku":"BRE8K-3URD-FT","price":2.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_eea410ca-934f-4420-93f0-650cc274a65a.jpg?v=1760026614"},{"product_id":"4-0-4-0-2-0-triplex-aluminum-direct-burial-cable-sweetbriar-8000-urd","title":"4\/0-4\/0-2\/0 Triplex Aluminum Direct Burial Cable, Sweetbriar 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e2\/0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e240 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e315 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761282362,"sku":"SWT8K-3URD-100","price":383.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761315130,"sku":"SWT8K-3URD-250","price":944.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761347898,"sku":"SWT8K-3URD-500","price":1877.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761380666,"sku":"SWT8K-3URD-1K","price":3735.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761413434,"sku":"SWT8K-3URD-FT","price":3.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_b5df4cbe-c61c-4dd7-bef7-f5fb18d3fc7d.jpg?v=1760026613"},{"product_id":"2-0-2-0-1-triplex-aluminum-direct-burial-cable-converse-8000-urd","title":"2\/0-2\/0-1 Triplex Aluminum Direct Burial Cable, Converse 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e1 AWG\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e180 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761446202,"sku":"CON8K-3URD-100","price":278.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761478970,"sku":"CON8K-3URD-250","price":685.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761511738,"sku":"CON8K-3URD-500","price":1363.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761544506,"sku":"CON8K-3URD-1K","price":2711.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761577274,"sku":"CON8K-3URD-FT","price":2.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_7ecd2bb7-a7ec-4a59-a8f4-4c4a2e6122e5.jpg?v=1760026614"},{"product_id":"4-0-4-0-4-0-triplex-aluminum-direct-burial-cable-monmouth-8000-urd","title":"4\/0-4\/0-4\/0 Triplex Aluminum Direct Burial Cable, Monmouth 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e4\/0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e240 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e315 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981762101562,"sku":"MON8K-3URD-100","price":424.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981762134330,"sku":"MON8K-3URD-250","price":1045.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981762167098,"sku":"MON8K-3URD-500","price":2078.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981762199866,"sku":"MON8K-3URD-1K","price":4134.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981762232634,"sku":"MON8K-3URD-FT","price":4.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_64982292-cbeb-4dcf-b2e6-ce135aadbfd2.jpg?v=1760026613"},{"product_id":"250-250-3-0-triplex-aluminum-direct-burial-cable-pratt-8000-urd","title":"250-250-3\/0 Triplex Aluminum Direct Burial Cable, Pratt 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e3\/0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e265 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury - \u003cstrong\u003e345 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761610042,"sku":"PRT8K-3URD-100","price":480.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761642810,"sku":"PRT8K-3URD-250","price":1182.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981761675578,"sku":"PRT8K-3URD-500","price":2352.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981761708346,"sku":"PRT8K-3URD-1K","price":4680.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981761741114,"sku":"PRT8K-3URD-FT","price":4.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_13f2d9d6-f4fd-425f-b709-56d40c04aedb.jpg?v=1760026614"},{"product_id":"350-350-4-0-triplex-aluminum-direct-burial-cable-wesleyan-8000-urd","title":"350-350-4\/0 Triplex Aluminum Direct Burial Cable, Wesleyan 8000 Series URD","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003eTriplex Aluminum 8000 Series, 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. This cable has 3 conductors. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR:\u003c\/strong\u003e\u003cbr\u003eCompact bare AA-8000 series aluminum alloy, Class B stranded per ASTM. The 8000 series aluminum alloy triplex is recommended when increased flexibility is needed.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND SIZE:\u003c\/strong\u003e\u003cbr\u003e4\/0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eBlack sunlight resistant cross-linked polyethylene (XLP) insulation. \u003cstrong\u003eThe 8000 Series is RHH, RHW-2, and USE-2 rated.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATING:\u003c\/strong\u003e\u003cbr\u003eDuct \/ Conduit - \u003cstrong\u003e320 Amps \u003cbr\u003e\u003c\/strong\u003eDirect Bury -\u003cstrong\u003e 415 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction. *Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW) **Ampacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981761937722,"sku":"WES8K-3URD-100","price":635.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981761970490,"sku":"WES8K-3URD-250","price":1564.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981762003258,"sku":"WES8K-3URD-500","price":3112.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981762036026,"sku":"WES8K-3URD-1K","price":6192.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981762068794,"sku":"WES8K-3URD-FT","price":6.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Ramapo_2-2-2_AWG_Triplex_Aluminum_URD_A_12f8f51b-9838-477d-93c3-3060e46b6d55.jpg?v=1760026614"},{"product_id":"tulsa-4-4-4-4-quadruplex-aluminum-direct-burial-wire-urd","title":"4-4-4-4 Quadruplex Aluminum Direct Burial Cable, Tulsa URD","description":"\u003cp data-path-to-node=\"4\"\u003e\u003cstrong\u003e\"The industry-standard for secondary three-phase residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"5\"\u003eWhy Electricians Choose Tulsa 4-4-4-4 Quadruplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe Tulsa 4-4-4-4 URD cable is the versatile solution for secondary underground \u003cb data-path-to-node=\"6\" data-index-in-node=\"80\"\u003ethree-phase\u003c\/b\u003e power distribution. Specifically designed for applications requiring three phase conductors and a neutral, it provides a stable, high-performance solution for light commercial services, multi-family residential projects, and agricultural power. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, providing dependable power for 3-phase equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"9\"\u003eTechnical Specifications: Tulsa 4-4-4-4 URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 4-4-4-4 Quadruplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Designed for use in secondary distribution circuits\u003cmeta charset=\"utf-8\"\u003ewhere installed in duct or direct burial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,5,0\"\u003e\u003cb data-path-to-node=\"11,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,6,0\"\u003e\u003cb data-path-to-node=\"11,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,7,0\"\u003e\u003cb data-path-to-node=\"11,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e \u003cspan\u003e0.83 inches (21.082 mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,8,0\"\u003e\u003cb data-path-to-node=\"11,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 120 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,9,0\"\u003e\u003cb data-path-to-node=\"11,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 85 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,10,0\"\u003e\u003cb data-path-to-node=\"11,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854; Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"3\"\u003eCommon 4-4-4-4 Tulsa Quadruplex Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,0,0\"\u003eThree-Phase Service Entrance:\u003c\/b\u003e The standard feeder for small commercial buildings or multi-family units requiring a 120\/208V or 277\/480V three-phase secondary service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,1,0\"\u003eSmall Industrial \u0026amp; Workshop Power:\u003c\/b\u003e Ideal for powering three-phase motors, air compressors, and specialized machinery in detached workshops or agricultural facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,2,0\"\u003eCommercial Site Lighting:\u003c\/b\u003e A rugged and cost-effective solution for underground power distribution to parking lot light poles and exterior security lighting circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,3,0\"\u003eAgricultural Infrastructure:\u003c\/b\u003e Frequently used for powering irrigation control systems and small-scale barn equipment where three-phase power is available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"4,4,0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Extremely versatile and easy to handle; can be installed directly in a trench for residential projects or pulled through conduit for commercial site developments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981762265402,"sku":"TUL-4URD-100","price":187.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981762298170,"sku":"TUL-4URD-250","price":461.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981762330938,"sku":"TUL-4URD-500","price":917.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981762363706,"sku":"TUL-4URD-1K","price":1824.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981762396474,"sku":"TUL-4URD-FT","price":1.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Dyke_2-2-2-4_AWG_Quadruplex_Aluminum_URD_B_ea92e138-c29f-4ad0-ad99-a9edc7e66053.jpg?v=1760026614"},{"product_id":"dyke-2-2-2-4-quadruplex-aluminum-direct-burial-wire-urd","title":"2-2-2-4 Quadruplex Aluminum Direct Burial Cable, Dyke URD","description":"\u003cp data-path-to-node=\"2\"\u003e\u003cstrong\u003e\"The industry-standard for secondary three-phase residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"3\"\u003eWhy Electricians Choose Dyke 2-2-2-4 Quadruplex Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe Dyke 2-2-2-4 URD cable is the preferred solution for secondary underground \u003cb data-path-to-node=\"4\" data-index-in-node=\"79\"\u003ethree-phase\u003c\/b\u003e power distribution in 100-Amp applications. Specifically designed for projects requiring three phase conductors and a neutral, it provides a stable, high-performance solution for individual apartment unit feeds, light commercial services, and agricultural sub-panels. By utilizing high-conductivity 1350-H19 aluminum and a heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C, providing dependable power for 100-Amp 3-phase equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points and service entrances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eEasy-Identify Neutral:\u003c\/b\u003e For faster installation and safer maintenance, the neutral conductor features three extruded yellow stripes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003eTechnical Specifications: Dyke 2-2-2-4 Aluminum URD\u003c\/h4\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 2-2-2-4 Quadruplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eQuadruplex Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 0.97 inches (24.64 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 155 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,9,0\"\u003e\u003cb data-path-to-node=\"9,9,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 115 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,10,0\"\u003e\u003cb data-path-to-node=\"9,10,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854; Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"11\"\u003eCommon 2-2-2-4 Dyke URD Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"12\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,0,0\"\u003e\u003cb data-path-to-node=\"12,0,0\" data-index-in-node=\"0\"\u003eApartment Unit Feeds:\u003c\/b\u003e The standard choice for running 3-phase 100-Amp power from a central distribution center to individual apartment sub-panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,1,0\"\u003e\u003cb data-path-to-node=\"12,1,0\" data-index-in-node=\"0\"\u003eLight Commercial Service:\u003c\/b\u003e Ideal for small retail units, offices, or workshops requiring a dedicated 3-phase service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,2,0\"\u003e\u003cb data-path-to-node=\"12,2,0\" data-index-in-node=\"0\"\u003eAgricultural Sub-Panels:\u003c\/b\u003e Frequently used to power detached barns, irrigation controls, and processing equipment where 3-phase power is available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,3,0\"\u003e\u003cb data-path-to-node=\"12,3,0\" data-index-in-node=\"0\"\u003eSite Infrastructure:\u003c\/b\u003e A durable and cost-effective solution for providing power to shared community amenities, such as pool houses or clubhouse facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"12,4,0\"\u003e\u003cb data-path-to-node=\"12,4,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Flexible enough for direct-trench installation or pull-through duct runs in multi-family site developments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"14,3,0\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"23\"\u003e\n\u003cp data-path-to-node=\"24\"\u003e\u003cb data-path-to-node=\"24\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAll values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eAmpacity: 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981762789690,"sku":"DYK-4URD-100","price":228.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981762822458,"sku":"DYK-4URD-250","price":562.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981762855226,"sku":"DYK-4URD-500","price":1118.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981762887994,"sku":"DYK-4URD-1K","price":2223.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981762920762,"sku":"DYK-4URD-FT","price":2.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Dyke_2-2-2-4_AWG_Quadruplex_Aluminum_URD_B_d4650fc5-176b-4ae9-9b21-886e73aae387.jpg?v=1760026614"},{"product_id":"notre-dame-1-0-1-0-1-0-2-quadruplex-aluminum-direct-burial-wire-urd","title":"1\/0-1\/0-1\/0-2 Quadruplex Aluminum Direct Burial Cable, Notre Dame URD","description":"\u003cp data-path-to-node=\"0\"\u003e\u003cstrong\u003e\"The industry-standard for secondary three-phase residential, farm, and commercial power distribution. Engineered for reliable 600V delivery, this cable is rated for both direct burial and duct installations, featuring sunlight-resistant XLP insulation for robust, long-term underground performance.\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eWhy Electricians Choose Notre Dame 1\/0-1\/0-1\/0-2 Quadruplex Aluminum URD\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe Notre Dame 1\/0-1\/0-1\/0-2 URD cable is the preferred solution for secondary underground three-phase power distribution in high-capacity applications. Specifically designed for projects requiring three phase conductors and a reduced neutral, it provides a stable, high-performance solution for commercial storefronts, heavy-duty agricultural feeds, and large residential sub-panels. By utilizing high-conductivity 1350-H19 aluminum and heavy-duty, sunlight-resistant XLP insulation, it offers superior resistance to environmental degradation, moisture ingress, and thermal stress.\u003c\/p\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003e600V Reliability:\u003c\/b\u003e Rated for continuous operation in wet or dry locations at temperatures up to 90°C. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSunlight-Resistant XLP:\u003c\/b\u003e Advanced cross-linked polyethylene insulation prevents premature aging caused by UV exposure at termination points and service entrances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eReduced Neutral Efficiency:\u003c\/b\u003e Features a #2 AWG neutral for systems where the neutral carries only the unbalanced load, reducing overall cable weight and cost without sacrificing safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eDirect Burial Ready:\u003c\/b\u003e Specifically built for the harsh conditions of underground utility distribution; can be installed directly in the earth or within conduit\/duct systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eTechnical Specifications: Notre Dame 1\/0-1\/0-1\/0-2 Aluminum URD\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eENGINEERING OVERVIEW: 1\/0-1\/0-1\/0-2 Quadruplex URD\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eApplication:\u003c\/b\u003e Quadruplex Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600 Volts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eUL Listing:\u003c\/b\u003e UL 854 (Service-Entrance Cable).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Concentric stranded 1350-H19 series aluminum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003ePhase Insulation:\u003c\/b\u003e Black sunlight-resistant XLP (Cross-Linked Polyethylene).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,5,0\"\u003e\u003cb data-path-to-node=\"6,5,0\" data-index-in-node=\"0\"\u003eNeutral Insulation:\u003c\/b\u003e Black XLP with 3 extruded yellow stripes for easy identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,6,0\"\u003e\u003cb data-path-to-node=\"6,6,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 90°C (Wet or Dry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,7,0\"\u003e\u003cb data-path-to-node=\"6,7,0\" data-index-in-node=\"0\"\u003ePhase Conductor Size:\u003c\/b\u003e 1\/0 AWG.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,8,0\"\u003e\u003cb data-path-to-node=\"6,8,0\" data-index-in-node=\"0\"\u003eNeutral Conductor Size:\u003c\/b\u003e #2 AWG (Reduced Neutral).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eCable Outer Diameter:\u003c\/b\u003e 1.24 inches (31.49 mm).\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,9,0\"\u003e\u003cb data-path-to-node=\"6,9,0\" data-index-in-node=\"0\"\u003eAmpacity (Direct Burial):\u003c\/b\u003e 200 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,10,0\"\u003e\u003cb data-path-to-node=\"6,10,0\" data-index-in-node=\"0\"\u003eAmpacity (In Duct):\u003c\/b\u003e 150 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,11,0\"\u003e\u003cb data-path-to-node=\"6,11,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e UL 854; Type USE-2; RUS Accepted; ASTM B-230, B-231, B-609, B-901; ICEA S-105-692.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eCommon 1\/0-1\/0-1\/0-2 Notre Dame URD Applications\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\"\u003eCommercial Service Entrances:\u003c\/b\u003e Ideal for retail units, offices, or workshops requiring a dedicated 150-Amp 3-phase service entrance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\"\u003eLarge Agricultural Sub-Panels:\u003c\/b\u003e Frequently used to power detached barns, large irrigation systems, and grain drying equipment where 3-phase power is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\"\u003eMulti-Family Feeder Lines:\u003c\/b\u003e The standard choice for running power from a main utility transformer to multi-unit residential meter banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\"\u003eIndustrial Site Infrastructure:\u003c\/b\u003e A durable and cost-effective solution for providing power to remote site facilities, security stations, or pump houses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\"\u003eDirect Burial or Conduit:\u003c\/b\u003e Flexible enough for direct-trench installation in rural areas or pull-through duct runs in developed commercial sites.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"9\"\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyer’s responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eAmpacity:\u003c\/b\u003e 90°C conductor temperature, 20°C ambient temperature, RHO 90, 100% load factor. Single and Quadruplex based on 3\/C. Neutral wire carries unbalanced load only. Reference NEC article 310.15 for NEC installations.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"100 ft. Spool","offer_id":51981763117370,"sku":"NDM-4URD-100","price":300.0,"currency_code":"USD","in_stock":true},{"title":"250 ft. Spool","offer_id":51981763150138,"sku":"NDM-4URD-250","price":739.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981763182906,"sku":"NDM-4URD-500","price":1470.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981763215674,"sku":"NDM-4URD-1K","price":2925.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981763248442,"sku":"NDM-4URD-FT","price":3.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Dyke_2-2-2-4_AWG_Quadruplex_Aluminum_URD_B_a790729f-37c7-4767-8bf5-a58cb0cb711c.jpg?v=1760026614"}],"url":"https:\/\/www.wireamerica.com\/collections\/urd-aluminum-direct-burial-cable.oembed","provider":"Wire America ","version":"1.0","type":"link"}